{"title":"Spectrophotometer Consumables","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#243746;font-size:15px;line-height:1.7\"\u003e\n\u003cdiv style=\"background:linear-gradient(125deg,#102a43 0%,#075b82 75%,#087f96 100%);padding:26px;color:#fff;border-radius:12px;margin-bottom:22px\"\u003e\n\u003cp style=\"font-size:12px;letter-spacing:1px;font-weight:700;color:#daf2fb;margin:0 0 8px\"\u003eUV-VIS ANALYSIS | LABORATORY SPECTROPHOTOMETRY\u003c\/p\u003e\n\u003ch2 style=\"font-size:26px;line-height:1.3;color:#fff;margin:0 0 10px\"\u003eSpectrophotometer Consumables, Cells, Cuvettes \u0026amp; Lamps\u003c\/h2\u003e\n\u003cp style=\"color:#fff;font-size:16px;margin:0\"\u003eExplore sample cells, optical cuvettes, replacement lamps and instrument-specific accessories for selected UV-Vis spectrophotometers, colorimeters and related analytical equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f0f7fb;border:1px solid #d5e5ef;border-radius:10px;padding:21px 22px;margin-bottom:23px\"\u003e\n\u003ch3 style=\"font-size:21px;color:#075b82;margin:0 0 9px\"\u003eFind the Right Spectrophotometer Consumables\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px\"\u003eAuckland Scientific's range includes \u003cstrong\u003eStarna and Hellma optical cells\u003c\/strong\u003e, \u003cstrong\u003eCamSpec instrument accessories\u003c\/strong\u003e, selected deuterium and tungsten lamps, sample holders and other spectrophotometry consumables. Choose by your instrument, measurement wavelength, required path length, sample volume and application.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px\"\u003eFor instrument-specific replacements, compare the manufacturer's model and exact accessory or lamp reference. For cells and cuvettes, check optical material, dimensions, path length, minimum sample volume and the suitable wavelength region.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#075b82;color:#fff!important;padding:12px 18px;border-radius:6px;text-decoration:none;font-weight:700;margin:3px 8px 3px 0\"\u003eAsk for Consumables Advice or a Quotation →\u003c\/a\u003e\n\u003ca href=\"tel:+447853690001\" style=\"display:inline-block;background:#fff;border:1px solid #075b82;color:#075b82!important;padding:11px 16px;border-radius:6px;text-decoration:none;font-weight:700;margin:3px 0\"\u003eCall Michael: 07853 690001\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"background:#075b82;color:#fff;font-size:21px;border-radius:7px;padding:10px 15px;margin:24px 0 13px\"\u003eExplore Spectrophotometer Consumable Types\u003c\/h3\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:12px;margin:15px 0 24px\"\u003e\n\u003cdiv style=\"border:1px solid #d8e5ed;border-radius:9px;background:#f3f8fb;padding:17px\"\u003e\n\u003cstrong style=\"color:#075b82\"\u003eSpectrophotometer Cells \u0026amp; Cuvettes\u003c\/strong\u003e\u003cp style=\"margin:7px 0 0\"\u003eBrowse optical glass, UV quartz and other specified cell materials, with different path lengths and formats for suitable absorption, fluorescence or colorimeter measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #d8e5ed;border-radius:9px;background:#f3f8fb;padding:17px\"\u003e\n\u003cstrong style=\"color:#075b82\"\u003eMicro \u0026amp; Semi-Micro Cells\u003c\/strong\u003e\u003cp style=\"margin:7px 0 0\"\u003eChoose sample cells appropriate to lower-volume measurements. Check minimum working volume, beam height and instrument holder compatibility.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #d8e5ed;border-radius:9px;background:#f3f8fb;padding:17px\"\u003e\n\u003cstrong style=\"color:#075b82\"\u003eInstrument Lamps\u003c\/strong\u003e\u003cp style=\"margin:7px 0 0\"\u003eReplacement deuterium (D2), visible or tungsten-halogen sources for selected instruments. Confirm the exact model and lamp part reference before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #d8e5ed;border-radius:9px;background:#f3f8fb;padding:17px\"\u003e\n\u003cstrong style=\"color:#075b82\"\u003eCuvette Holders \u0026amp; Accessories\u003c\/strong\u003e\u003cp style=\"margin:7px 0 0\"\u003eSelected CamSpec holders, adapters and compatible cell accessories for different vessel types, instrument designs and measurement setups.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"background:#075b82;color:#fff;font-size:21px;border-radius:7px;padding:10px 15px;margin:24px 0 13px\"\u003eChoosing an Optical Cell for UV-Vis Measurements\u003c\/h3\u003e\n\u003cul style=\"padding-left:23px;margin:13px 0 22px\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical material:\u003c\/strong\u003e check the manufacturer's transmission specifications for UV quartz, optical glass or other listed materials. Not all cells transmit the same wavelength range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical path length:\u003c\/strong\u003e compare 10 mm standard cells and other path lengths with the intended method and instrument holder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample volume:\u003c\/strong\u003e check the required fill level, beam position and minimum working volume for micro or semi-micro formats.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCell geometry:\u003c\/strong\u003e select square, cylindrical, fluorescence or other compatible designs to suit the instrument and measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosures and accessories:\u003c\/strong\u003e verify caps, stoppers, screw threads and temperature-control or mixing features where relevant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaning and handling:\u003c\/strong\u003e follow the cell manufacturer's instructions, including any chemical compatibility and optical-surface care requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"background:#eaf3f8;border-left:4px solid #087f96;border-radius:5px;padding:16px 18px;margin:0 0 22px\"\u003e\u003cstrong style=\"color:#075b82\"\u003eInstrument compatibility:\u003c\/strong\u003e An accessory, cuvette or replacement lamp should not be assumed compatible with every spectrophotometer. Verify the full instrument model, beam height, holder requirements, optical material and product reference. Manufacturer names in product descriptions identify the intended application and do not necessarily indicate OEM manufacture or endorsement.\u003c\/p\u003e\n\u003cdiv style=\"background:#fff;border:1px solid #d8e5ed;border-radius:10px;padding:20px 22px;margin:20px 0\"\u003e\n\u003ch3 style=\"color:#075b82;font-size:20px;margin:0 0 9px\"\u003eBrowse Related Collections\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 13px\"\u003eFind the specific type of spectrophotometer consumable or equipment you need in our related categories.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:9px\"\u003e\n\u003ca href=\"\/collections\/spectrophotometer-cells\" style=\"display:inline-block;background:#075b82;color:#fff!important;text-decoration:none;font-weight:700;padding:11px 14px;border-radius:6px\"\u003eSpectrophotometer Cells →\u003c\/a\u003e\n\u003ca href=\"\/collections\/spectrophotometer-cell-accessories\" style=\"display:inline-block;background:#075b82;color:#fff!important;text-decoration:none;font-weight:700;padding:11px 14px;border-radius:6px\"\u003eCell Accessories →\u003c\/a\u003e\n\u003ca href=\"\/collections\/spectrophotometer-detector-lamps\" style=\"display:inline-block;background:#fff;border:1px solid #075b82;color:#075b82!important;text-decoration:none;font-weight:700;padding:10px 13px;border-radius:6px\"\u003eDetector Lamps →\u003c\/a\u003e\n\u003ca href=\"\/collections\/spectrophotometers\" style=\"display:inline-block;background:#fff;border:1px solid #075b82;color:#075b82!important;text-decoration:none;font-weight:700;padding:10px 13px;border-radius:6px\"\u003eSpectrophotometers →\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#102a43;color:#fff;border-radius:12px;padding:23px\"\u003e\n\u003ch3 style=\"color:#fff;font-size:21px;margin:0 0 9px\"\u003eNeed Help Identifying a Spectrophotometer Consumable?\u003c\/h3\u003e\n\u003cp style=\"color:#e1f1fa;margin:0 0 14px\"\u003eContact Auckland Scientific with your instrument make and model, required cell or lamp reference, wavelength range, path length or sample volume. We can help compare suitable options and provide a quotation.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#075b82!important;font-weight:700;text-decoration:none;padding:12px 18px;border-radius:6px\"\u003eContact Auckland Scientific →\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","products":[{"product_id":"camspec-spectrophotometer-4-cell-holder-for-10-100mm-cells","title":"Camspec Spectrophotometer 4 cell holder for 10 - 100mm cells","description":"\u003ch1\u003eCamspec Spectrophotometer 4 cell holder for 10 - 100mm cells\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCell changer for 4 x 5-100mm cells. Applicable to CamSpec spectrophotometer models M108, M508, M209T, M509T, M501 and M550.\u003c\/span\u003e\u003c\/p\u003e","brand":"Camspec","offers":[{"title":"Default Title","offer_id":58587166441797,"sku":"501-103","price":315.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/4cellholder10-100mm.jpg?v=1784223244"},{"product_id":"camspec-spectrophotometer-post-2017-tungsten-halogen-lamp-pack-of-2","title":"Camspec Spectrophotometer (Post 2017) Tungsten - Halogen Lamp Pack of 2","description":"\u003ch1\u003eCamspec Spectrophotometer (Post 2017) Tungsten - Halogen Lamp \u003c\/h1\u003e\n\u003cp\u003ePack of 2\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFits Camspec Spectrophotometers Post 2017 models:\u003c\/p\u003e\n\u003cp\u003eM108\u003c\/p\u003e\n\u003cp\u003eM508\u003c\/p\u003e\n\u003cp\u003eM209T\u003c\/p\u003e\n\u003cp\u003eM509T\u003c\/p\u003e\n\u003cp\u003eM501\u003c\/p\u003e\n\u003cp\u003eM550\u003c\/p\u003e","brand":"Camspec","offers":[{"title":"Default Title","offer_id":58587451261253,"sku":"VIS28","price":132.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/Vis28lamps.jpg?v=1784225616"},{"product_id":"camspec-spectrophotometer-pre-aligned-deuterium-lamp","title":"Camspec Spectrophotometer Pre Aligned Deuterium Lamp","description":"\u003ch1\u003eCamspec Spectrophotometer Pre Aligned Deuterium Lamp\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003ePre-aligned Deuterium lamp for M508\/M501\/M509T\u003c\/p\u003e","brand":"Camspec","offers":[{"title":"Default Title","offer_id":58587456930117,"sku":"550-516N6","price":447.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/PrealignedDeuteriumlamp.jpg?v=1784225800"},{"product_id":"camspec-spectrophotometer-pre-aligned-deuterium-lamp-m550-post-2018","title":"Camspec Spectrophotometer Pre Aligned Deuterium Lamp for M550 Only Post 2018","description":"\u003ch1\u003eCamspec Spectrophotometer Pre Aligned Deuterium Lamp for M550 Only\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003ePre-aligned Deuterium lamp for M550 Post 2018\u003c\/p\u003e","brand":"Camspec","offers":[{"title":"Default Title","offer_id":58588345532741,"sku":"550-516N3","price":447.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/PrealignedDeuteriumlamp.jpg?v=1784225800"},{"product_id":"tungsten-halogen-lamps-for-camspec-m105-m106-spectrophotometers-pack-of-2","title":"Tungsten - Halogen Lamps for Camspec M105 \u0026 M106 Spectrophotometers (Pack of 2)","description":"","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":58618360987973,"sku":"VIS27","price":123.28,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/Vis28lamps.jpg?v=1784225616"},{"product_id":"test-tube-sample-holder-for-10mm-test-tubes-for-camspec-m105-m106-spectrophotometers","title":"Test Tube Sample Holder for 10mm Test Tubes for Camspec M105 \u0026 M106 Spectrophotometers","description":"","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":58618383499589,"sku":"1100-102","price":100.68,"currency_code":"GBP","in_stock":true}]},{"product_id":"spare-adapter-for-square-10mm-cuvettes-for-camspec-m105-m106-spectrophotometers","title":"Spare Adapter for Square 10mm Cuvettes for Camspec M105 \u0026 M106 Spectrophotometers","description":"","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":58618397393221,"sku":"1100-103","price":50.0,"currency_code":"GBP","in_stock":true}]},{"product_id":"holder-for-20mm-diameter-test-tube-for-camspec-m105-m106-spectrophotometers","title":"Holder for 20mm Diameter Test Tube for Camspec M105 \u0026 M106 Spectrophotometers","description":"","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":58618415677765,"sku":"1100-113","price":50.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/modern_20_mm_test_tube_holder_rack.png?v=1794256761"},{"product_id":"holder-for-25mm-diameter-test-tube-for-camspec-m105-m106-spectrophotometers","title":"Holder for 25mm Diameter Test Tube for Camspec M105 \u0026 M106 Spectrophotometers","description":"","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":58618417185093,"sku":"1100-114","price":50.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/laboratory_test_tube_holder_rack.png?v=1794256770"},{"product_id":"hellma-type-104-precision-quartz-cells-micro-semi-micro-fluorescence","title":"Hellma Type 104 Precision Quartz Cells – Micro, Semi-Micro \u0026 Fluorescence","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n  \u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eHellma Type 104 Precision Quartz Cells\u003c\/h2\u003e\n  \u003cp\u003eHigh-precision Hellma cells for UV\/Vis and selected fluorescence measurements, available in micro, semi-micro and extended-range configurations. These reusable precision cells are thermally bonded rather than glued for excellent chemical and temperature resistance.\u003c\/p\u003e\n\n  \u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n    \u003cstrong style=\"color:#005f91;\"\u003eChoose the correct configuration\u003c\/strong\u003e\u003cbr\u003e\n    Select the required cell by sample volume, optical material, path length and measurement type. If you are unsure which cell is suitable for your spectrophotometer or application, Auckland Scientific can help.\n  \u003c\/div\u003e\n\n  \u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eHellma precision cell family for absorption and fluorescence measurements\u003c\/li\u003e\n    \u003cli\u003eHigh-performance quartz options covering 200–2500 nm\u003c\/li\u003e\n    \u003cli\u003eExtended-range quartz option covering 200–3500 nm\u003c\/li\u003e\n    \u003cli\u003eMicro and semi-micro sample volumes available\u003c\/li\u003e\n    \u003cli\u003ePrecision path length and parallelism for reproducible measurements\u003c\/li\u003e\n    \u003cli\u003eThermally bonded construction with no adhesive in the optical cell body\u003c\/li\u003e\n    \u003cli\u003eSuitable for common spectrophotometers\u003c\/li\u003e\n    \u003cli\u003eRoHS and REACH compliant according to manufacturer information\u003c\/li\u003e\n    \u003cli\u003eManufactured in Germany\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n  \u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n        \u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eSKU\u003c\/th\u003e\n        \u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eType\u003c\/th\u003e\n        \u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003ePath Length\u003c\/th\u003e\n        \u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eVolume\u003c\/th\u003e\n        \u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eWavelength\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL104-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSemi-Micro, QS\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL104-002-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eMicro, QS\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e700 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL104002B-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eMicro, black glass body \/ QS windows\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e700 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL104F-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSemi-Micro Fluorescence, 4 windows\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 × 4 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL104-B-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSemi-Micro, black glass body \/ QS windows\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL104-5-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSemi-Micro, QS\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e700 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL104-50-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSemi-Micro, QS\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e50 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e7 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL104-10-K-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eMatched Semi-Micro Cell Pair, QS\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL each\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL104-10-46\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSemi-Micro, QX Extended Range\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–3500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL104002F-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eMicro Fluorescence, 4 windows\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 × 2 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e700 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003ch3 style=\"color:#005f91;\"\u003eApplications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eUV\/Vis absorption spectroscopy\u003c\/li\u003e\n    \u003cli\u003eUV\/Vis\/NIR measurements with the QX extended-range option\u003c\/li\u003e\n    \u003cli\u003eFluorescence spectroscopy with four-window configurations\u003c\/li\u003e\n    \u003cli\u003eLow-volume sample measurement\u003c\/li\u003e\n    \u003cli\u003eRoutine laboratory and analytical spectroscopy\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n    \u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\n    Compatibility depends on the required path length, sample volume, wavelength range and instrument cell holder. \u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hellma","offers":[{"title":"104-QS Semi-Micro 10 mm, 1.4 mL","offer_id":59795761004869,"sku":"HL104-10-40","price":150.18,"currency_code":"GBP","in_stock":true},{"title":"104-002-QS Micro 10 mm, 700 µL","offer_id":59795761037637,"sku":"HL104-002-10-40","price":185.26,"currency_code":"GBP","in_stock":true},{"title":"104.002B-QS Micro Black Body 10 mm, 700 µL","offer_id":59795761070405,"sku":"HL104002B-10-40","price":305.84,"currency_code":"GBP","in_stock":true},{"title":"104F-QS Fluorescence 10×4 mm, 1.4 mL","offer_id":59795761103173,"sku":"HL104F-10-40","price":347.5,"currency_code":"GBP","in_stock":true},{"title":"104-B-QS Semi-Micro Black Body 10 mm, 1.4 mL","offer_id":59795761135941,"sku":"HL104-B-10-40","price":265.28,"currency_code":"GBP","in_stock":true},{"title":"104-QS Semi-Micro 5 mm, 700 µL","offer_id":59795761168709,"sku":"HL104-5-40","price":174.3,"currency_code":"GBP","in_stock":true},{"title":"104-QS Semi-Micro 50 mm, 7 mL","offer_id":59795761201477,"sku":"HL104-50-40","price":320.09,"currency_code":"GBP","in_stock":true},{"title":"104-QS Matched Pair 10 mm, 1.4 mL","offer_id":59795761234245,"sku":"HL104-10-K-40","price":327.77,"currency_code":"GBP","in_stock":true},{"title":"104-QX Extended Range 10 mm, 1.4 mL","offer_id":59795761267013,"sku":"HL104-10-46","price":199.51,"currency_code":"GBP","in_stock":true},{"title":"104.002F-QS Fluorescence 10×2 mm, 700 µL","offer_id":59795761299781,"sku":"HL104002F-10-40","price":386.96,"currency_code":"GBP","in_stock":true},{"title":"104.002B-OS Micro Black Body 10 mm, 700 µL","offer_id":59796248691013,"sku":"HL104002B-10-20","price":144.7,"currency_code":"GBP","in_stock":false},{"title":"104.002-OS Micro 10 mm, 700 µL","offer_id":59796248723781,"sku":"HL104-002-10-20","price":94.6,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/hellma-104-10-40.jpg?v=1792265871"},{"product_id":"hellma-type-115-precision-micro-cells-absorption-fluorescence","title":"Hellma Type 115 Precision Micro Cells – Absorption \u0026 Fluorescence","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eHellma Type 115 Precision Micro Cells\u003c\/h2\u003e\n\u003cp\u003ePrecision 400 µL Hellma micro cells with PTFE stopper for low-volume UV\/Vis absorption and fluorescence measurements.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct configuration\u003c\/strong\u003e\u003cbr\u003eSelect the required variant by measurement type, sample volume and cell construction. If you are unsure which option suits your instrument, Auckland Scientific can help.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHellma precision quartz cells for UV\/Vis spectroscopy\u003c\/li\u003e\n\u003cli\u003eHigh-performance quartz, 200–2500 nm\u003c\/li\u003e\n\u003cli\u003eThermally bonded construction for chemical and temperature resistance\u003c\/li\u003e\n\u003cli\u003ePrecision optical path for reproducible measurements\u003c\/li\u003e\n\u003cli\u003eSuitable for common spectrophotometers\u003c\/li\u003e\n\u003cli\u003eManufactured in Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL115-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e115-QS Absorption, 10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e400 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL115-F-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e115F-QS Fluorescence, 10 × 2 mm, 4 windows\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e400 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL115B-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e115B-QS Black Body, 10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e400 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-volume UV\/Vis absorption spectroscopy\u003c\/li\u003e\n\u003cli\u003eFluorescence measurements\u003c\/li\u003e\n\u003cli\u003eRoutine analytical spectroscopy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hellma","offers":[{"title":"115-QS Absorption 10 mm, 400 µL","offer_id":59796038648133,"sku":"HL115-10-40","price":221.44,"currency_code":"GBP","in_stock":true},{"title":"115F-QS Fluorescence 10×2 mm, 400 µL","offer_id":59796038680901,"sku":"HL115-F-10-40","price":415.46,"currency_code":"GBP","in_stock":true},{"title":"115B-QS Black Body 10 mm, 400 µL","offer_id":59796038713669,"sku":"HL115B-10-40","price":416.56,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/hellma-115-10-40.jpg?v=1792266332"},{"product_id":"hellma-type-114-precision-semi-micro-cells-absorption-fluorescence","title":"Hellma Type 114 Precision Semi-Micro Cells – Absorption \u0026 Fluorescence","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eHellma Type 114 Precision Semi-Micro Cells\u003c\/h2\u003e\n\u003cp\u003ePrecision 1.4 mL Hellma semi-micro cells with PTFE stopper for UV\/Vis absorption and fluorescence measurements.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct configuration\u003c\/strong\u003e\u003cbr\u003eSelect the required variant by measurement type, sample volume and cell construction. If you are unsure which option suits your instrument, Auckland Scientific can help.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHellma precision quartz cells for UV\/Vis spectroscopy\u003c\/li\u003e\n\u003cli\u003eHigh-performance quartz, 200–2500 nm\u003c\/li\u003e\n\u003cli\u003eThermally bonded construction for chemical and temperature resistance\u003c\/li\u003e\n\u003cli\u003ePrecision optical path for reproducible measurements\u003c\/li\u003e\n\u003cli\u003eSuitable for common spectrophotometers\u003c\/li\u003e\n\u003cli\u003eManufactured in Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL114-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e114-QS Absorption, 10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL114F-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e114F-QS Fluorescence, 10 × 4 mm, 4 windows\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL114B-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e114B-QS Black Body, 10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUV\/Vis absorption spectroscopy\u003c\/li\u003e\n\u003cli\u003eFluorescence measurements\u003c\/li\u003e\n\u003cli\u003eGeneral analytical laboratory use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hellma","offers":[{"title":"114-QS Absorption 10 mm, 1.4 mL","offer_id":59796039729477,"sku":"HL114-10-40","price":416.56,"currency_code":"GBP","in_stock":true},{"title":"114F-QS Fluorescence 10×4 mm, 1.4 mL","offer_id":59796039762245,"sku":"HL114F-10-40","price":427.52,"currency_code":"GBP","in_stock":true},{"title":"114B-QS Black Body 10 mm, 1.4 mL","offer_id":59796039795013,"sku":"HL114B-10-40","price":416.56,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/hellma-114-10-40.jpg?v=1792266349"},{"product_id":"hellma-type-108-precision-micro-semi-micro-cells-9-mm-base","title":"Hellma Type 108 Precision Micro \u0026 Semi-Micro Cells – 9 mm Base","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eHellma Type 108 Precision Cells\u003c\/h2\u003e\n\u003cp\u003eHellma Type 108 micro and semi-micro quartz cells with 9 mm base thickness, including absorption, fluorescence and black-body configurations.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct configuration\u003c\/strong\u003e\u003cbr\u003eSelect the required variant by measurement type, sample volume and cell construction. If you are unsure which option suits your instrument, Auckland Scientific can help.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHellma precision quartz cells for UV\/Vis spectroscopy\u003c\/li\u003e\n\u003cli\u003eHigh-performance quartz, 200–2500 nm\u003c\/li\u003e\n\u003cli\u003e500 µL micro and 1 mL semi-micro options\u003c\/li\u003e\n\u003cli\u003e9 mm base thickness\u003c\/li\u003e\n\u003cli\u003eThermally bonded construction for chemical and temperature resistance\u003c\/li\u003e\n\u003cli\u003ePrecision optical path for reproducible measurements\u003c\/li\u003e\n\u003cli\u003eSuitable for common spectrophotometers\u003c\/li\u003e\n\u003cli\u003eManufactured in Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL108-000-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e108-QS Absorption, 10 mm, 9 mm base\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL108B-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e108B-QS Black Body, 10 mm, 9 mm base\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL108-F-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e108F-QS Fluorescence, 10 × 4 mm, 9 mm base\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL108-002-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e108.002-QS Absorption, 10 mm, 9 mm base\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e500 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL108002B-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e108.002B-QS Black Body, 10 mm, 9 mm base\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e500 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL108002F-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e108.002F-QS Fluorescence, 10 × 2 mm, magnetic stirrer\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e500 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-volume UV\/Vis spectroscopy\u003c\/li\u003e\n\u003cli\u003eFluorescence measurements\u003c\/li\u003e\n\u003cli\u003eApplications requiring elevated optical window position\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hellma","offers":[{"title":"108F-QS Fluorescence 10×4 mm, 1 mL","offer_id":59796041040197,"sku":"HL108-F-10-40","price":440.68,"currency_code":"GBP","in_stock":true},{"title":"108B-QS Black Body 10 mm, 1 mL","offer_id":59796041072965,"sku":"HL108B-10-40","price":321.19,"currency_code":"GBP","in_stock":true},{"title":"108.002F-QS Fluorescence 10×2 mm, 500 µL","offer_id":59796041105733,"sku":"HL108002F-10-40","price":416.56,"currency_code":"GBP","in_stock":true},{"title":"108.002B-QS Black Body 10 mm, 500 µL","offer_id":59796041138501,"sku":"HL108002B-10-40","price":404.5,"currency_code":"GBP","in_stock":true},{"title":"108.002-QS Absorption 10 mm, 500 µL","offer_id":59796055392581,"sku":"HL108-002-10-40","price":213.76,"currency_code":"GBP","in_stock":false},{"title":"108-QS Absorption 10 mm, 1 mL","offer_id":59796055425349,"sku":"HL108-000-10-40","price":199.51,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/hellma-108-f-10-40.jpg?v=1792266416"},{"product_id":"hellma-type-105-precision-micro-cell-300-µl","title":"Hellma Type 105 Precision Micro Cell – 300 µL","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eHellma Type 105 Precision Micro Cell\u003c\/h2\u003e\n\u003cp\u003eCompact 300 µL high-performance quartz micro cell for UV\/Vis absorption measurements.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct configuration\u003c\/strong\u003e\u003cbr\u003eSelect the option that matches your measurement method and sample requirements. If you are unsure which cell is suitable for your instrument, Auckland Scientific can help.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHellma precision quartz construction\u003c\/li\u003e\n\u003cli\u003e200–2500 nm wavelength range\u003c\/li\u003e\n\u003cli\u003eThermally bonded rather than glued\u003c\/li\u003e\n\u003cli\u003ePrecision optical path for reproducible measurements\u003c\/li\u003e\n\u003cli\u003eSuitable for common spectrophotometers\u003c\/li\u003e\n\u003cli\u003eManufactured in Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL105-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e105-QS Absorption, 10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e300 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUV\/Vis spectroscopy\u003c\/li\u003e\n\u003cli\u003eRoutine analytical laboratory measurements\u003c\/li\u003e\n\u003cli\u003eLow-volume sample analysis where applicable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hellma","offers":[{"title":"105-QS 10 mm, 300 µL","offer_id":59796059783493,"sku":"HL105-10-40","price":164.43,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/hellma-105-10-40.jpg?v=1792266708"},{"product_id":"hellma-type-109-precision-cells-with-magnetic-stirrer","title":"Hellma Type 109 Precision Cells with Magnetic Stirrer","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eHellma Type 109 Precision Cells with Magnetic Stirrer\u003c\/h2\u003e\n\u003cp\u003eHigh-performance quartz semi-micro cells with integrated magnetic stirring for absorption or fluorescence measurements.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct configuration\u003c\/strong\u003e\u003cbr\u003eSelect the option that matches your measurement method and sample requirements. If you are unsure which cell is suitable for your instrument, Auckland Scientific can help.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHellma precision quartz construction\u003c\/li\u003e\n\u003cli\u003e200–2500 nm wavelength range\u003c\/li\u003e\n\u003cli\u003eThermally bonded rather than glued\u003c\/li\u003e\n\u003cli\u003ePrecision optical path for reproducible measurements\u003c\/li\u003e\n\u003cli\u003eSuitable for common spectrophotometers\u003c\/li\u003e\n\u003cli\u003eManufactured in Germany\u003c\/li\u003e\n\u003cli\u003eIntegrated magnetic stirrer\u003c\/li\u003e\n\u003cli\u003eAbsorption and 4-window fluorescence options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL109-004-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e109-QS Absorption, 10 mm, magnetic stirrer\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.5 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL109004F-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e109F-QS Fluorescence, 10 × 4 mm, magnetic stirrer\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.5 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUV\/Vis spectroscopy\u003c\/li\u003e\n\u003cli\u003eRoutine analytical laboratory measurements\u003c\/li\u003e\n\u003cli\u003eLow-volume sample analysis where applicable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hellma","offers":[{"title":"109-QS Absorption 10 mm, 1.5 mL","offer_id":59796059849029,"sku":"HL109-004-10-40","price":269.67,"currency_code":"GBP","in_stock":true},{"title":"109F-QS Fluorescence 10×4 mm, 1.5 mL","offer_id":59796059881797,"sku":"HL109004F-10-40","price":453.83,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/hellma-109-004-10-40.jpg?v=1792266713"},{"product_id":"hellma-type-117-precision-semi-micro-cells-with-gl14-screw-cap","title":"Hellma Type 117 Precision Semi-Micro Cells with GL14 Screw Cap","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eHellma Type 117 Precision Semi-Micro Cells\u003c\/h2\u003e\n\u003cp\u003e1.4 mL high-performance quartz semi-micro cells with GL14 screw-cap closures, available for absorption and fluorescence measurements with silicone or PTFE sealing configurations.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct configuration\u003c\/strong\u003e\u003cbr\u003eSelect the option that matches your measurement method and sample requirements. If you are unsure which cell is suitable for your instrument, Auckland Scientific can help.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHellma precision quartz construction\u003c\/li\u003e\n\u003cli\u003e200–2500 nm wavelength range\u003c\/li\u003e\n\u003cli\u003eThermally bonded rather than glued\u003c\/li\u003e\n\u003cli\u003ePrecision optical path for reproducible measurements\u003c\/li\u003e\n\u003cli\u003eSuitable for common spectrophotometers\u003c\/li\u003e\n\u003cli\u003eManufactured in Germany\u003c\/li\u003e\n\u003cli\u003eGL14 screw-cap closure\u003c\/li\u003e\n\u003cli\u003eSilicone and PTFE sealing options\u003c\/li\u003e\n\u003cli\u003eAbsorption and 4-window fluorescence versions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL117-104-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e117-QS Absorption, GL14 + silicone seal\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL117104F-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e117F-QS Fluorescence, GL14 + silicone seal\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL117-204-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e117-QS Absorption, GL14 + PTFE seal\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL117204F-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e117F-QS Fluorescence, GL14 + PTFE seal\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUV\/Vis spectroscopy\u003c\/li\u003e\n\u003cli\u003eRoutine analytical laboratory measurements\u003c\/li\u003e\n\u003cli\u003eLow-volume sample analysis where applicable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hellma","offers":[{"title":"117-QS Absorption, Silicone Seal","offer_id":59796061815109,"sku":"HL117-104-10-40","price":373.81,"currency_code":"GBP","in_stock":true},{"title":"117F-QS Fluorescence, Silicone Seal","offer_id":59796061847877,"sku":"HL117104F-10-40","price":574.42,"currency_code":"GBP","in_stock":true},{"title":"117-QS Absorption, PTFE Seal","offer_id":59796061880645,"sku":"HL117-204-10-40","price":373.81,"currency_code":"GBP","in_stock":true},{"title":"117F-QS Fluorescence, PTFE Seal","offer_id":59796061913413,"sku":"HL117204F-10-40","price":574.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/hellma-117-104-10-40.jpg?v=1792266723"},{"product_id":"hellma-type-119-precision-cells-with-magnetic-stirrer-ptfe-stopper","title":"Hellma Type 119 Precision Cells with Magnetic Stirrer \u0026 PTFE Stopper","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eHellma Type 119 Precision Cells\u003c\/h2\u003e\n\u003cp\u003eHigh-performance quartz semi-micro cells with magnetic stirrer and PTFE stopper for absorption and fluorescence measurements.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct configuration\u003c\/strong\u003e\u003cbr\u003eSelect the option that matches your measurement method and sample requirements. If you are unsure which cell is suitable for your instrument, Auckland Scientific can help.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHellma precision quartz construction\u003c\/li\u003e\n\u003cli\u003e200–2500 nm wavelength range\u003c\/li\u003e\n\u003cli\u003eThermally bonded rather than glued\u003c\/li\u003e\n\u003cli\u003ePrecision optical path for reproducible measurements\u003c\/li\u003e\n\u003cli\u003eSuitable for common spectrophotometers\u003c\/li\u003e\n\u003cli\u003eManufactured in Germany\u003c\/li\u003e\n\u003cli\u003eIntegrated magnetic stirrer\u003c\/li\u003e\n\u003cli\u003ePTFE stopper\u003c\/li\u003e\n\u003cli\u003eAbsorption and 4-window fluorescence options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL119-004-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e119-QS Absorption, 10 mm, magnetic stirrer\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.5 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL119004F-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e119F-QS Fluorescence, 10 × 4 mm, magnetic stirrer\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.5 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUV\/Vis spectroscopy\u003c\/li\u003e\n\u003cli\u003eRoutine analytical laboratory measurements\u003c\/li\u003e\n\u003cli\u003eLow-volume sample analysis where applicable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hellma","offers":[{"title":"119-QS Absorption 10 mm, 1.5 mL","offer_id":59796061946181,"sku":"HL119-004-10-40","price":322.29,"currency_code":"GBP","in_stock":true},{"title":"119F-QS Fluorescence 10×4 mm, 1.5 mL","offer_id":59796061978949,"sku":"HL119004F-10-40","price":533.86,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/hellma-119-004-10-40.webp?v=1792266742"},{"product_id":"hellma-type-121-cylindrical-quartz-cells-0-1-to-1-mm-path-length","title":"Hellma Type 121 Cylindrical Quartz Cells – 0.1 to 1 mm Path Length","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;\"\u003eHellma Type 121 Cylindrical Quartz Cells\u003c\/h2\u003e\n\u003cp\u003eHigh-performance quartz cylindrical cells with very short optical path lengths for absorption measurements.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct configuration\u003c\/strong\u003e\u003cbr\u003eSelect the required cell by path length, material and measurement method. \u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e if you need help.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrecision Hellma spectroscopy cell\u003c\/li\u003e\n\u003cli\u003eThermally bonded construction\u003c\/li\u003e\n\u003cli\u003eReusable laboratory cell\u003c\/li\u003e\n\u003cli\u003eManufactured in Germany\u003c\/li\u003e\n\u003cli\u003eHigh-performance quartz glass\u003c\/li\u003e\n\u003cli\u003eCylindrical cell format\u003c\/li\u003e\n\u003cli\u003eVery short path lengths for strongly absorbing samples\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL121-0.10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e0.1 mm path length, 2 PTFE stoppers\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e160 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL121-0.20-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e0.2 mm path length, 2 PTFE stoppers\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e170 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL121-0.50-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e0.5 mm path length, 2 PTFE stoppers\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e210 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL121-1-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1 mm path length, 2 PTFE stoppers\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e280 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUV\/Vis spectroscopy\u003c\/li\u003e\n\u003cli\u003eAnalytical laboratory measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hellma","offers":[{"title":"0.1 mm – 160 µL","offer_id":59796283425093,"sku":"HL121-0.10-40","price":533.86,"currency_code":"GBP","in_stock":true},{"title":"0.2 mm – 170 µL","offer_id":59796283457861,"sku":"HL121-0.20-40","price":533.86,"currency_code":"GBP","in_stock":true},{"title":"0.5 mm – 210 µL","offer_id":59796283490629,"sku":"HL121-0.50-40","price":533.86,"currency_code":"GBP","in_stock":true},{"title":"1 mm – 280 µL","offer_id":59796283523397,"sku":"HL121-1-40","price":533.86,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/hellma-121-0-10-40.jpg?v=1792267092"},{"product_id":"hellma-type-111-057-qs-fluorescence-micro-cell-850-µl","title":"Hellma Type 111.057-QS Fluorescence Micro Cell – 850 µL","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;\"\u003eHellma Type 111.057-QS Fluorescence Micro Cell\u003c\/h2\u003e\n\u003cp\u003eHigh-performance quartz fluorescence micro cell with five optical windows and PTFE stopper.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct configuration\u003c\/strong\u003e\u003cbr\u003eSelect the required cell by path length, material and measurement method. \u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e if you need help.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrecision Hellma spectroscopy cell\u003c\/li\u003e\n\u003cli\u003eThermally bonded construction\u003c\/li\u003e\n\u003cli\u003eReusable laboratory cell\u003c\/li\u003e\n\u003cli\u003eManufactured in Germany\u003c\/li\u003e\n\u003cli\u003eFive optical windows\u003c\/li\u003e\n\u003cli\u003ePTFE stopper\u003c\/li\u003e\n\u003cli\u003eDesigned for fluorescence measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL111-057-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e5 × 5 mm fluorescence path, 5 windows\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e850 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUV\/Vis spectroscopy\u003c\/li\u003e\n\u003cli\u003eAnalytical laboratory measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hellma","offers":[{"title":"111.057-QS 5×5 mm, 850 µL","offer_id":59796286767429,"sku":"HL111-057-40","price":339.83,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/hellma-111-057-40.jpg?v=1792267097"},{"product_id":"hellma-type-165-qs-temperature-controlled-macro-cylindrical-cell-800-µl","title":"Hellma Type 165-QS Temperature-Controlled Macro Cylindrical Cell – 800 µL","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;\"\u003eHellma Type 165-QS Macro Cylindrical Cell\u003c\/h2\u003e\n\u003cp\u003eTemperature-controlled high-performance quartz macro cylindrical cell with inlet\/outlet tubes for UV\/Vis absorption measurements.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct configuration\u003c\/strong\u003e\u003cbr\u003eSelect the required cell by path length, material and measurement method. \u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e if you need help.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrecision Hellma spectroscopy cell\u003c\/li\u003e\n\u003cli\u003eThermally bonded construction\u003c\/li\u003e\n\u003cli\u003eReusable laboratory cell\u003c\/li\u003e\n\u003cli\u003eManufactured in Germany\u003c\/li\u003e\n\u003cli\u003eTemperature-controlled design\u003c\/li\u003e\n\u003cli\u003eInlet and outlet tubes\u003c\/li\u003e\n\u003cli\u003e10 mm optical path length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL165-10-40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm path, 10 mm inner diameter, inlet\/outlet tubes\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e800 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUV\/Vis spectroscopy\u003c\/li\u003e\n\u003cli\u003eAnalytical laboratory measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hellma","offers":[{"title":"165-QS 10 mm, 800 µL","offer_id":59796291617093,"sku":"HL165-10-40","price":372.71,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/hellma-165-10-40.jpg?v=1792267102"},{"product_id":"hellma-type-6040-semi-micro-cells-optical-glass-uv-quartz","title":"Hellma Type 6040 Semi-Micro Cells – Optical Glass \u0026 UV Quartz","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;\"\u003eHellma Type 6040 Semi-Micro Cells\u003c\/h2\u003e\n\u003cp\u003eEconomical 1.4 mL semi-micro cells available in optical glass for visible measurements or UV quartz for UV\/Vis use.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct configuration\u003c\/strong\u003e\u003cbr\u003eSelect the required cell by path length, material and measurement method. \u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e if you need help.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrecision Hellma spectroscopy cell\u003c\/li\u003e\n\u003cli\u003eThermally bonded construction\u003c\/li\u003e\n\u003cli\u003eReusable laboratory cell\u003c\/li\u003e\n\u003cli\u003eManufactured in Germany\u003c\/li\u003e\n\u003cli\u003e10 mm optical path\u003c\/li\u003e\n\u003cli\u003eOptical glass and UV quartz options\u003c\/li\u003e\n\u003cli\u003ePTFE lid\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL6040-10-10\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e6040-OG Optical Glass, 10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eHL6040-UV-10-531\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e6040-UV Quartz Glass, 10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e260–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUV\/Vis spectroscopy\u003c\/li\u003e\n\u003cli\u003eAnalytical laboratory measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hellma","offers":[{"title":"Optical Glass 360–2500 nm","offer_id":59796292796741,"sku":"HL6040-10-10","price":74.87,"currency_code":"GBP","in_stock":true},{"title":"UV Quartz 260–2500 nm","offer_id":59796292829509,"sku":"HL6040-UV-10-531","price":116.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/hellma-6040-10-10.jpg?v=1792267113"},{"product_id":"starna-type-96-optical-glass-colorimeter-cells-2-5-to-100-mm-path-length","title":"Starna Type 96 Optical Glass Colorimeter Cells – 2.5 to 100 mm Path Length","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eStarna Type 96 Colorimeter Cells\u003c\/h2\u003e\n\u003cp\u003eFully fused optical glass colorimeter cells with U-shaped wall construction, two polished windows and an open top. These reusable cells are suitable for visible-range absorption and colorimetric measurements.\u003c\/p\u003e\n\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct path length\u003c\/strong\u003e\u003cbr\u003e\nSelect the path length required for your method and instrument. Longer path lengths increase optical interaction length and can be useful for low-absorbance samples. If you are unsure which cell is suitable, \u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003econtact Auckland Scientific for advice\u003c\/a\u003e.\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStarna Type 96 fully fused colorimeter cells\u003c\/li\u003e\n\u003cli\u003eOptical glass construction\u003c\/li\u003e\n\u003cli\u003eWavelength range: 360–2500 nm\u003c\/li\u003e\n\u003cli\u003eU-shaped wall construction\u003c\/li\u003e\n\u003cli\u003eTwo polished optical windows\u003c\/li\u003e\n\u003cli\u003eOpen-top design\u003c\/li\u003e\n\u003cli\u003eAvailable in path lengths from 2.5 to 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003ePath Length\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eMaterial\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN96\/G\/2.5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e2.5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN96\/G\/5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN96\/G\/10\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN96\/G\/20\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e20 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN96\/G\/40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e40 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN96\/G\/100\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e100 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005f91;\"\u003eTechnical Document\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.analytics-shop.com\/media\/pdfs\/Starna_Type_93-96_cells.pdf\" target=\"_blank\" rel=\"noopener\" style=\"color:#005f91;font-weight:600;\"\u003eView Starna Type 93\/96 cell data sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\n\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"2.5 mm","offer_id":59796454277445,"sku":"SN96\/G\/2.5","price":54.9,"currency_code":"GBP","in_stock":true},{"title":"5 mm","offer_id":59796454310213,"sku":"SN96\/G\/5","price":48.57,"currency_code":"GBP","in_stock":true},{"title":"10 mm","offer_id":59796454342981,"sku":"SN96\/G\/10","price":53.77,"currency_code":"GBP","in_stock":true},{"title":"20 mm","offer_id":59796454375749,"sku":"SN96\/G\/20","price":79.94,"currency_code":"GBP","in_stock":true},{"title":"40 mm","offer_id":59796454408517,"sku":"SN96\/G\/40","price":110.68,"currency_code":"GBP","in_stock":true},{"title":"100 mm","offer_id":59796454441285,"sku":"SN96\/G\/100","price":169.63,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-96-cells.jpg?v=1792267336"},{"product_id":"starna-type-53-dual-path-uv-quartz-fluorimeter-cells-with-ptfe-stopper","title":"Starna Type 53 Dual-Path UV Quartz Fluorimeter Cells with PTFE Stopper","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eStarna Type 53 Dual-Path Fluorimeter Cells\u003c\/h2\u003e\n\u003cp\u003eUV quartz dual-path cells designed to support both fluorescence and absorbance measurements with small sample volumes. Each cell provides a 10 mm optical path in one direction and a shorter secondary path at 90°.\u003c\/p\u003e\n\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eDual-path flexibility\u003c\/strong\u003e\u003cbr\u003e\nRotate the cell in the holder to select the 10 mm path or the shorter secondary path. All four windows and the base are clear, and Type 53 cells are supplied with a PTFE stopper.\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStarna Type 53 UV quartz fluorimeter cells\u003c\/li\u003e\n\u003cli\u003eSuitable for both fluorescence and absorbance measurements\u003c\/li\u003e\n\u003cli\u003ePrimary optical path: 10 mm\u003c\/li\u003e\n\u003cli\u003eSecondary path options: 1, 2, 3, 4 or 5 mm\u003c\/li\u003e\n\u003cli\u003eWavelength range: 200–2500 nm\u003c\/li\u003e\n\u003cli\u003eFour clear optical windows\u003c\/li\u003e\n\u003cli\u003eClear base\u003c\/li\u003e\n\u003cli\u003eSupplied with PTFE stopper\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eSecondary Path\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003ePrimary Path\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN53\/Q\/1\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN53\/Q\/2\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e2 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN53\/Q\/3\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e3 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN53\/Q\/4\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e4 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN53\/Q\/5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005f91;\"\u003eTechnical Document\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.analytics-shop.com\/media\/pdfs\/Starna_Type_52-53_cells.pdf\" target=\"_blank\" rel=\"noopener\" style=\"color:#005f91;font-weight:600;\"\u003eView Starna Type 52\/53 cell data sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\n\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"1 mm","offer_id":59796454637893,"sku":"SN53\/Q\/1","price":348.34,"currency_code":"GBP","in_stock":true},{"title":"2 mm","offer_id":59796454670661,"sku":"SN53\/Q\/2","price":348.34,"currency_code":"GBP","in_stock":true},{"title":"3 mm","offer_id":59796454703429,"sku":"SN53\/Q\/3","price":348.34,"currency_code":"GBP","in_stock":true},{"title":"4 mm","offer_id":59796454736197,"sku":"SN53\/Q\/4","price":348.34,"currency_code":"GBP","in_stock":true},{"title":"5 mm","offer_id":59796454768965,"sku":"SN53\/Q\/5","price":295.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-53-cells.jpg?v=1792267341"},{"product_id":"starna-type-52-dual-path-uv-quartz-fluorimeter-cells-with-ptfe-lid","title":"Starna Type 52 Dual-Path UV Quartz Fluorimeter Cells with PTFE Lid","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eStarna Type 52 Dual-Path Fluorimeter Cells\u003c\/h2\u003e\n\u003cp\u003eUV quartz dual-path cells designed for both fluorescence and absorbance measurements with small sample volumes. Each cell provides a 10 mm optical path in one direction and a shorter secondary path at 90°.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eDual-path flexibility\u003c\/strong\u003e\u003cbr\u003eRotate the cell in the holder to select the 10 mm path or the shorter secondary path. All four windows and the base are clear.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStarna Type 52 UV quartz fluorimeter cells\u003c\/li\u003e\n\u003cli\u003eSuitable for fluorescence and absorbance measurements\u003c\/li\u003e\n\u003cli\u003ePrimary optical path: 10 mm\u003c\/li\u003e\n\u003cli\u003eSecondary path options: 1, 2, 3, 4 or 5 mm\u003c\/li\u003e\n\u003cli\u003eWavelength range: 200–2500 nm\u003c\/li\u003e\n\u003cli\u003eFour clear optical windows\u003c\/li\u003e\n\u003cli\u003eClear base\u003c\/li\u003e\n\u003cli\u003eOpen-top design with lid\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSecondary Path\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003ePrimary Path\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN52\/Q\/1\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN52\/Q\/2\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e2 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN52\/Q\/3\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e3 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN52\/Q\/4\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e4 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN52\/Q\/5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTechnical Document\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.analytics-shop.com\/media\/pdfs\/Starna_Type_52-53_cells.pdf\" target=\"_blank\" rel=\"noopener\" style=\"color:#005f91;font-weight:600;\"\u003eView Starna Type 52\/53 cell data sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"1 mm","offer_id":59796482261317,"sku":"SN52\/Q\/1","price":285.49,"currency_code":"GBP","in_stock":true},{"title":"2 mm","offer_id":59796482294085,"sku":"SN52\/Q\/2","price":285.49,"currency_code":"GBP","in_stock":true},{"title":"3 mm","offer_id":59796482326853,"sku":"SN52\/Q\/3","price":285.49,"currency_code":"GBP","in_stock":true},{"title":"4 mm","offer_id":59796482359621,"sku":"SN52\/Q\/4","price":285.49,"currency_code":"GBP","in_stock":true},{"title":"5 mm","offer_id":59796482392389,"sku":"SN52\/Q\/5","price":285.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-52-cells.jpg?v=1792267495"},{"product_id":"starna-type-9-semi-micro-spectrophotometer-cells-uv-quartz-special-optical-glass","title":"Starna Type 9 Semi-Micro Spectrophotometer Cells – UV Quartz \u0026 Special Optical Glass","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eStarna Type 9 Semi-Micro Cells\u003c\/h2\u003e\n\u003cp\u003eRectangular semi-micro spectrophotometer cells with a 4 mm-wide sample chamber and two clear windows. Available in UV quartz for UV\/Vis measurements and special optical glass for visible-range work.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct material and path length\u003c\/strong\u003e\u003cbr\u003eUV quartz options cover 170–2700 nm, while the special optical glass version covers 320–2500 nm. If you need help matching a cell to your instrument, \u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003econtact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-micro rectangular cell format\u003c\/li\u003e\n\u003cli\u003e4 mm-wide sample chamber\u003c\/li\u003e\n\u003cli\u003eTwo clear optical windows\u003c\/li\u003e\n\u003cli\u003eOpen top with non-sealing PTFE cover\u003c\/li\u003e\n\u003cli\u003eUV quartz and special optical glass options\u003c\/li\u003e\n\u003cli\u003eSuitable for spectrophotometers and, for SOG version, colorimeters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eMaterial\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003ePath Length\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN9\/Q\/5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eUV Quartz\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e700 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e170–2700 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN9\/Q\/10\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eUV Quartz\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e170–2700 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN9\/Q\/20\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eUV Quartz\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e20 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e2.8 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e170–2700 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN9\/Q\/50\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eUV Quartz\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e50 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e7 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e170–2700 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN9\/SOG\/10\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSpecial Optical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1.4 mL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e320–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTechnical Document\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.analytics-shop.com\/media\/pdfs\/Starna_Type_9_cells.pdf\" target=\"_blank\" rel=\"noopener\" style=\"color:#005f91;font-weight:600;\"\u003eView Starna Type 9 cell data sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"UV Quartz 5 mm, 700 µL","offer_id":59796482883909,"sku":"SN9\/Q\/5","price":178.22,"currency_code":"GBP","in_stock":true},{"title":"UV Quartz 10 mm, 1.4 mL","offer_id":59796482916677,"sku":"SN9\/Q\/10","price":141.92,"currency_code":"GBP","in_stock":true},{"title":"UV Quartz 20 mm, 2.8 mL","offer_id":59796482949445,"sku":"SN9\/Q\/20","price":237.42,"currency_code":"GBP","in_stock":true},{"title":"UV Quartz 50 mm, 7 mL","offer_id":59796482982213,"sku":"SN9\/Q\/50","price":316.72,"currency_code":"GBP","in_stock":true},{"title":"Special Optical Glass 10 mm, 1.4 mL","offer_id":59796483014981,"sku":"SN9\/SOG\/10","price":77.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-9-q-cells.jpg?v=1792267500"},{"product_id":"starna-type-16-sub-micro-uv-quartz-cells-100-160-µl","title":"Starna Type 16 Sub-Micro UV Quartz Cells – 100 \u0026 160 µL","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eStarna Type 16 Sub-Micro UV Quartz Cells\u003c\/h2\u003e\n\u003cp\u003eLow-volume UV quartz spectrophotometer cells with a 2 mm-wide sample chamber and two clear optical windows. Available in 100 µL and 160 µL volumes with alternative Z-dimensions for instrument compatibility.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eCheck the Z-dimension before ordering\u003c\/strong\u003e\u003cbr\u003eThese cells are available with 8.5 mm or 15 mm Z-height options. Please confirm the optical centre height required by your spectrophotometer. \u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e if you are unsure.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSub-micro UV quartz cells\u003c\/li\u003e\n\u003cli\u003e10 mm path length\u003c\/li\u003e\n\u003cli\u003e170–2700 nm usable range\u003c\/li\u003e\n\u003cli\u003e2 mm-wide sample chamber\u003c\/li\u003e\n\u003cli\u003eTwo clear windows\u003c\/li\u003e\n\u003cli\u003eOpen top with PTFE non-sealing cover and polyethylene liquid-tight cover\u003c\/li\u003e\n\u003cli\u003e100 µL and 160 µL versions\u003c\/li\u003e\n\u003cli\u003e8.5 mm and 15 mm Z-dimension options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eZ-Dimension\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003ePath Length\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN16.100\/Q\/10\/Z8.5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e100 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e8.5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN16.100\/Q\/10\/Z15\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e100 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e15 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN16.160\/Q\/10\/Z8.5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e160 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e8.5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN16.160\/Q\/10\/Z15\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e160 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e15 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTechnical Document\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.analytics-shop.com\/media\/pdfs\/Starna_Type_16_cells.pdf\" target=\"_blank\" rel=\"noopener\" style=\"color:#005f91;font-weight:600;\"\u003eView Starna Type 16 cell data sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"100 µL – Z 8.5 mm","offer_id":59796529250629,"sku":"SN16.100\/Q\/10\/Z8.5","price":378.95,"currency_code":"GBP","in_stock":true},{"title":"100 µL – Z 15 mm","offer_id":59796529283397,"sku":"SN16.100\/Q\/10\/Z15","price":378.95,"currency_code":"GBP","in_stock":true},{"title":"160 µL – Z 8.5 mm","offer_id":59796529316165,"sku":"SN16.160\/Q\/10\/Z8.5","price":378.95,"currency_code":"GBP","in_stock":true},{"title":"160 µL – Z 15 mm","offer_id":59796529348933,"sku":"SN16.160\/Q\/10\/Z15","price":378.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-16-submicro.jpg?v=1792267676"},{"product_id":"starna-type-32-uv-quartz-cylindrical-cells-with-ptfe-stopper-1-2-mm","title":"Starna Type 32 UV Quartz Cylindrical Cells with PTFE Stopper – 1 \u0026 2 mm","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eStarna Type 32 Short-Path Cylindrical Cells\u003c\/h2\u003e\n\u003cp\u003eUV quartz cylindrical cells with PTFE stopper for short-path absorbance measurements. These cells are useful where a very short optical path is required for strongly absorbing samples.\u003c\/p\u003e\n\u003cdiv style=\"background:#fff8e6;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eImportant filling guidance\u003c\/strong\u003e\u003cbr\u003eDo not fill cylindrical cells completely to the top. Leave an air gap before inserting the PTFE stopper to avoid hydraulic pressure damaging the optical windows.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUV quartz cylindrical construction\u003c\/li\u003e\n\u003cli\u003eShort path lengths: 1 mm and 2 mm\u003c\/li\u003e\n\u003cli\u003ePTFE stopper supplied\u003c\/li\u003e\n\u003cli\u003e200–2500 nm usable range\u003c\/li\u003e\n\u003cli\u003eSuitable for high-absorbance samples and short-path measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003ePath Length\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eNominal Volume\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN32\/Q\/1\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e1 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e280 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN32\/Q\/2\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e2 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e560 µL\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e200–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTechnical Document\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.analytics-shop.com\/media\/pdfs\/Starna_Type_32-34_clyindrical_cells.pdf\" target=\"_blank\" rel=\"noopener\" style=\"color:#005f91;font-weight:600;\"\u003eView Starna Type 32\/34 cylindrical cell data sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"1 mm – 280 µL","offer_id":59796529742149,"sku":"SN32\/Q\/1","price":284.23,"currency_code":"GBP","in_stock":true},{"title":"2 mm – 560 µL","offer_id":59796529774917,"sku":"SN32\/Q\/2","price":284.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-32-cylindrical.jpg?v=1792267681"},{"product_id":"starna-type-18b-self-masking-micro-cell-700-µl","title":"Starna Type 18B Self-Masking Micro Cell – 700 µL","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eStarna Type 18B Self-Masking Micro Cell\u003c\/h2\u003e\n\u003cp\u003eSelf-masking micro cell for spectrophotometry, with black walls parallel to the light beam and two clear optical windows. The sample chamber is 2 mm wide and the cell is supplied with a non-sealing PTFE cover.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e700 µL micro cell\u003c\/li\u003e\n\u003cli\u003e10 mm path length\u003c\/li\u003e\n\u003cli\u003e2 mm-wide sample chamber\u003c\/li\u003e\n\u003cli\u003eBlack side walls for self-masking\u003c\/li\u003e\n\u003cli\u003eTwo clear optical windows\u003c\/li\u003e\n\u003cli\u003eOpen top with PTFE cover\u003c\/li\u003e\n\u003cli\u003eSuitable for spectrophotometers\u003c\/li\u003e\n\u003cli\u003eSpecified usable range: 320–2500 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTechnical Document\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.analytics-shop.com\/media\/pdfs\/Starna_Type_18_cells.pdf\" target=\"_blank\" rel=\"noopener\" style=\"color:#005f91;font-weight:600;\"\u003eView Starna Type 18 cell data sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help checking compatibility?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"18B 10 mm, 700 µL","offer_id":59796530069829,"sku":"SN18\/B\/Q\/10","price":276.63,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-18b-micro.jpg?v=1792267687"},{"product_id":"starna-type-9-semi-micro-uv-quartz-cell-with-gl14-screw-cap-septum","title":"Starna Type 9 Semi-Micro UV Quartz Cell with GL14 Screw Cap \u0026 Septum","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eStarna Type 9 Semi-Micro Cell with GL14 Screw Cap\u003c\/h2\u003e\n\u003cp\u003eUV quartz semi-micro rectangular cell with a sealing GL14 screw cap and silicone septum. The cap includes a central access hole so the septum can be pierced with a syringe needle.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10 mm path length\u003c\/li\u003e\n\u003cli\u003e1.4 mL nominal volume\u003c\/li\u003e\n\u003cli\u003eUV quartz glass\u003c\/li\u003e\n\u003cli\u003e200–2500 nm usable range\u003c\/li\u003e\n\u003cli\u003e4 mm-wide sample chamber\u003c\/li\u003e\n\u003cli\u003eTwo clear optical windows\u003c\/li\u003e\n\u003cli\u003eSealing GL14 screw cap\u003c\/li\u003e\n\u003cli\u003eSilicone septum for syringe access\u003c\/li\u003e\n\u003cli\u003eSuitable for storage, mixing, spectrophotometers and colorimeters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTechnical Document\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.analytics-shop.com\/media\/pdfs\/Starna_Type_9_cells.pdf\" target=\"_blank\" rel=\"noopener\" style=\"color:#005f91;font-weight:600;\"\u003eView Starna Type 9 cell data sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"10 mm, 1.4 mL, GL14 Septum Cap","offer_id":59796530266437,"sku":"SN9\/Q\/10\/GL14\/S","price":314.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-9-gl14-s.jpg?v=1792267692"},{"product_id":"starna-ptfe-coated-magnetic-stir-bars-for-ms-cells-packs-of-10","title":"Starna PTFE-Coated Magnetic Stir Bars for MS Cells – Packs of 10","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eStarna Magnetic Stir Bars for MS Cells\u003c\/h2\u003e\n\u003cp\u003ePTFE-coated magnetic stirring bars for Starna MS cell applications, supplied in packs of 10. Different bar dimensions are available to suit the internal geometry of different cells.\u003c\/p\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eCompatibility note\u003c\/strong\u003e\u003cbr\u003eTypes 18\/MS and 28\/MS require the 6 × 1.5 mm stir bar so that the bar can enter the narrow sample compartment. \u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e if you are unsure which size you need.\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Sizes\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003eDimensions\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;\"\u003ePack Size\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSNMSB\/5x2\/10\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e5 mm × 2 mm Ø\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSNMSB\/6x1.5\/10\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e6 mm × 1.5 mm Ø\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSNMSB\/6x3\/10\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e6 mm × 3 mm Ø\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePTFE-coated\u003c\/li\u003e\n\u003cli\u003eDesigned for Starna MS cells\u003c\/li\u003e\n\u003cli\u003ePack of 10\u003c\/li\u003e\n\u003cli\u003eMultiple dimensions available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct stir bar?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"5 × 2 mm – Pack 10","offer_id":59796530495813,"sku":"SNMSB\/5x2\/10","price":38.84,"currency_code":"GBP","in_stock":true},{"title":"6 × 1.5 mm – Pack 10","offer_id":59796530528581,"sku":"SNMSB\/6x1.5\/10","price":42.75,"currency_code":"GBP","in_stock":true},{"title":"6 × 3 mm – Pack 10","offer_id":59796530561349,"sku":"SNMSB\/6x3\/10","price":34.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/Starna-Scientific-logo.png?v=1792268806"},{"product_id":"starna-type-98-optical-glass-colorimeter-cells-2-5-to-40-mm-path-length","title":"Starna Type 98 Optical Glass Colorimeter Cells – 2.5 to 40 mm Path Length","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eStarna Type 98 Colorimeter Cells\u003c\/h2\u003e\n\u003cp\u003eFully fused optical glass absorption\/colorimeter cells with two polished windows and U-shaped wall construction. Type 98 cells are available in a wide range of path lengths for visible-range colorimetric and absorption measurements.\u003c\/p\u003e\n\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct path length\u003c\/strong\u003e\u003cbr\u003e\nSelect the optical path required by your method and instrument. If you are unsure which configuration is suitable, \u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003econtact Auckland Scientific for advice\u003c\/a\u003e.\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStarna Type 98 absorption\/colorimeter cell family\u003c\/li\u003e\n\u003cli\u003eOptical glass construction\u003c\/li\u003e\n\u003cli\u003eFully fused design\u003c\/li\u003e\n\u003cli\u003eTwo polished optical windows\u003c\/li\u003e\n\u003cli\u003eU-shaped wall construction\u003c\/li\u003e\n\u003cli\u003eUsable wavelength range: 360–2500 nm\u003c\/li\u003e\n\u003cli\u003ePath lengths from 2.5 to 40 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003ePath Length\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eMaterial\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN98\/G\/2.5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e2.5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN98\/G\/5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN98\/G\/10\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN98\/G\/13\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e13 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN98\/G\/15\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e15 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN98\/G\/20\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e20 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN98\/G\/25\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e25 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN98\/G\/30\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e30 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN98\/G\/33\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e33 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN98\/G\/40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e40 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOptical Glass\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005f91;\"\u003eTechnical Information\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.starna.com\/colorimeter\/macro\" target=\"_blank\" rel=\"noopener\" style=\"color:#005f91;font-weight:600;\"\u003eView Starna Type 98 technical information\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\n\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"2.5 mm","offer_id":59796610679109,"sku":"SN98\/G\/2.5","price":70.32,"currency_code":"GBP","in_stock":true},{"title":"5 mm","offer_id":59796610711877,"sku":"SN98\/G\/5","price":57.68,"currency_code":"GBP","in_stock":true},{"title":"10 mm","offer_id":59796610744645,"sku":"SN98\/G\/10","price":57.68,"currency_code":"GBP","in_stock":true},{"title":"13 mm","offer_id":59796610777413,"sku":"SN98\/G\/13","price":70.84,"currency_code":"GBP","in_stock":true},{"title":"15 mm","offer_id":59796610810181,"sku":"SN98\/G\/15","price":74.13,"currency_code":"GBP","in_stock":true},{"title":"20 mm","offer_id":59796610842949,"sku":"SN98\/G\/20","price":94.49,"currency_code":"GBP","in_stock":true},{"title":"25 mm","offer_id":59796610875717,"sku":"SN98\/G\/25","price":102.85,"currency_code":"GBP","in_stock":true},{"title":"30 mm","offer_id":59796610908485,"sku":"SN98\/G\/30","price":106.39,"currency_code":"GBP","in_stock":true},{"title":"33 mm","offer_id":59796610941253,"sku":"SN98\/G\/33","price":119.29,"currency_code":"GBP","in_stock":true},{"title":"40 mm","offer_id":59796610974021,"sku":"SN98\/G\/40","price":131.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-98-colorimeter-cells.jpg?v=1792269415"},{"product_id":"starna-type-97-optical-glass-colorimeter-cells-multiple-formats-path-lengths","title":"Starna Type 97 Optical Glass Colorimeter Cells – Multiple Formats \u0026 Path Lengths","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;margin-bottom:8px;\"\u003eStarna Type 97 Colorimeter Cells\u003c\/h2\u003e\n\u003cp\u003eFully fused optical glass absorption\/colorimeter cells with two polished windows and U-shaped wall construction. Type 97 configurations are available in several body formats and path lengths for colorimetric and absorption measurements.\u003c\/p\u003e\n\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eChoose the correct Type 97 configuration\u003c\/strong\u003e\u003cbr\u003e\nThe Type 97 range includes 97.40, 97.45 and 97.60 formats. Select the exact configuration and path length required by your method or instrument. \u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e if you need help.\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStarna Type 97 absorption\/colorimeter cell family\u003c\/li\u003e\n\u003cli\u003eOptical glass construction\u003c\/li\u003e\n\u003cli\u003eFully fused design\u003c\/li\u003e\n\u003cli\u003eTwo polished optical windows\u003c\/li\u003e\n\u003cli\u003eU-shaped wall construction\u003c\/li\u003e\n\u003cli\u003eUsable wavelength range: 360–2500 nm\u003c\/li\u003e\n\u003cli\u003eMultiple body formats and path lengths\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background:#005f91;color:#fff;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eFormat\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003ePath Length\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eWavelength\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.40\/G\/2.5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e2.5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.40\/G\/5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.40\/G\/10\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.40\/G\/20\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e20 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.40\/G\/40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e40 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.40\/G\/50\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e50 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.40\/G\/100\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e100 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.45\/G\/40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.45\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e40 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.60\/G\/2.5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.60\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e2.5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.60\/G\/5\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.60\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.60\/G\/10\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.60\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e10 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.60\/G\/20\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.60\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e20 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSN97.60\/G\/40\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e97.60\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e40 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e360–2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#005f91;\"\u003eTechnical Information\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.starna.com\/colorimeter\/macro\" target=\"_blank\" rel=\"noopener\" style=\"color:#005f91;font-weight:600;\"\u003eView Starna Type 97 technical information\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #d9d9d9;padding:14px 16px;margin-top:20px;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help choosing the correct cell?\u003c\/strong\u003e\u003cbr\u003e\n\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"97.40 – 2.5 mm","offer_id":59796611006789,"sku":"SN97.40\/G\/2.5","price":44.16,"currency_code":"GBP","in_stock":true},{"title":"97.40 – 5 mm","offer_id":59796611039557,"sku":"SN97.40\/G\/5","price":39.09,"currency_code":"GBP","in_stock":true},{"title":"97.40 – 10 mm","offer_id":59796611072325,"sku":"SN97.40\/G\/10","price":39.09,"currency_code":"GBP","in_stock":true},{"title":"97.40 – 20 mm","offer_id":59796611105093,"sku":"SN97.40\/G\/20","price":63.74,"currency_code":"GBP","in_stock":true},{"title":"97.40 – 40 mm","offer_id":59796611137861,"sku":"SN97.40\/G\/40","price":89.05,"currency_code":"GBP","in_stock":true},{"title":"97.40 – 50 mm","offer_id":59796611170629,"sku":"SN97.40\/G\/50","price":122.69,"currency_code":"GBP","in_stock":true},{"title":"97.40 – 100 mm","offer_id":59796611203397,"sku":"SN97.40\/G\/100","price":136.99,"currency_code":"GBP","in_stock":true},{"title":"97.45 – 40 mm","offer_id":59796611236165,"sku":"SN97.45\/G\/40","price":89.05,"currency_code":"GBP","in_stock":true},{"title":"97.60 – 2.5 mm","offer_id":59796611268933,"sku":"SN97.60\/G\/2.5","price":48.57,"currency_code":"GBP","in_stock":true},{"title":"97.60 – 5 mm","offer_id":59796611301701,"sku":"SN97.60\/G\/5","price":42.88,"currency_code":"GBP","in_stock":true},{"title":"97.60 – 10 mm","offer_id":59796611334469,"sku":"SN97.60\/G\/10","price":42.88,"currency_code":"GBP","in_stock":true},{"title":"97.60 – 20 mm","offer_id":59796611367237,"sku":"SN97.60\/G\/20","price":69.82,"currency_code":"GBP","in_stock":true},{"title":"97.60 – 40 mm","offer_id":59796611400005,"sku":"SN97.60\/G\/40","price":97.78,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-97-colorimeter-cells.jpg?v=1792269408"},{"product_id":"starna-spinette-cell-stirrer-110-vac-240-vac","title":"Starna SPINETTE Cell Stirrer – 110 VAC \u0026 240 VAC","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;\"\u003eStarna SPINETTE Cell Stirrer\u003c\/h2\u003e\n\u003cp\u003eA compact magnetic cell stirring system for mixing solutions directly inside spectrophotometer or fluorometer cells.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupplied complete with speed controller, electronic rotation platform, ribbon cable and one stir bar\u003c\/li\u003e\n\u003cli\u003eDesigned for use with suitable 10 mm cells and Starna MS stirring cells\u003c\/li\u003e\n\u003cli\u003eTypical aqueous samples can be mixed rapidly in-cell\u003c\/li\u003e\n\u003cli\u003eAvailable in 110 VAC and 240 VAC versions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed compatibility advice?\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"110 VAC","offer_id":59796616839493,"sku":"SNSCS1.11","price":900.33,"currency_code":"GBP","in_stock":true},{"title":"240 VAC","offer_id":59796616872261,"sku":"SNSCS1.22","price":900.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-spinette-cell-stirrer.jpg?v=1792269571"},{"product_id":"starna-96-mcb-optical-glass-cell-for-macbeth-colorimeter-10-mm","title":"Starna 96\/MCB Optical Glass Cell for Macbeth Colorimeter – 10 mm","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;\"\u003eStarna 96\/MCB Macbeth Colorimeter Cell\u003c\/h2\u003e\n\u003cp\u003eFully fused optical glass colorimeter cell with two polished windows and U-shaped wall construction, intended for Macbeth colorimeter applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10 mm path length\u003c\/li\u003e\n\u003cli\u003eOptical glass\u003c\/li\u003e\n\u003cli\u003e360–2500 nm usable range\u003c\/li\u003e\n\u003cli\u003eOpen top\u003c\/li\u003e\n\u003cli\u003eTwo polished windows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #ddd;padding:14px 16px;\"\u003e\n\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"10 mm","offer_id":59796616905029,"sku":"SN96\/MCB\/G\/10","price":66.53,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-96-mcb-colorimeter.gif?v=1792269576"},{"product_id":"starna-type-73-65-f-uv-quartz-fluorescence-flow-cells-z-8-5-15-mm","title":"Starna Type 73.65-F UV Quartz Fluorescence Flow Cells – Z 8.5 \u0026 15 mm","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;\"\u003eStarna Type 73.65-F Fluorescence Flow Cells\u003c\/h2\u003e\n\u003cp\u003eWide-aperture UV quartz fluorescence flow cells for continuous-flow and dissolution applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10 mm path length\u003c\/li\u003e\n\u003cli\u003eUV quartz\u003c\/li\u003e\n\u003cli\u003e200–2500 nm\u003c\/li\u003e\n\u003cli\u003eWide aperture\u003c\/li\u003e\n\u003cli\u003ePush-on tube connections\u003c\/li\u003e\n\u003cli\u003e2 mm ID \/ 4 mm OD inlet-outlet tubes\u003c\/li\u003e\n\u003cli\u003eZ-height options: 8.5 mm and 15 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#eef7fb;border-left:4px solid #005f91;padding:14px 16px;margin:18px 0;\"\u003e\n\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e to confirm Z-height compatibility.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"8.5 mm","offer_id":59796616937797,"sku":"SN73.65-F\/Q\/10\/Z8.5","price":802.06,"currency_code":"GBP","in_stock":true},{"title":"15 mm","offer_id":59796616970565,"sku":"SN73.65-F\/Q\/10\/Z15","price":802.06,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-73-65-fluorescence-flow.jpg?v=1792269593"},{"product_id":"starna-type-72-f-uv-quartz-fluorescence-flow-cell-10-mm","title":"Starna Type 72-F UV Quartz Fluorescence Flow Cell – 10 mm","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;\"\u003eStarna Type 72-F Fluorescence Flow Cell\u003c\/h2\u003e\n\u003cp\u003eUV quartz fluorescence flow cell with long sample compartment, reduced volume and three polished windows.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10 mm path length\u003c\/li\u003e\n\u003cli\u003eUV quartz glass\u003c\/li\u003e\n\u003cli\u003e200–2500 nm\u003c\/li\u003e\n\u003cli\u003eThree polished windows\u003c\/li\u003e\n\u003cli\u003eSuitable for all Z dimensions\u003c\/li\u003e\n\u003cli\u003e2 mm ID \/ 4 mm OD inlet-outlet tubes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #ddd;padding:14px 16px;\"\u003e\n\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"10 mm","offer_id":59796617003333,"sku":"SN72-F\/Q\/10","price":709.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna_72F_illustrative.jpg?v=1794253882"},{"product_id":"starna-type-71-f-uv-quartz-fluorescence-flow-cell-10-mm","title":"Starna Type 71-F UV Quartz Fluorescence Flow Cell – 10 mm","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;\"\u003eStarna Type 71-F Fluorescence Flow Cell\u003c\/h2\u003e\n\u003cp\u003eMaximum-aperture UV quartz fluorescence flow cell with three polished windows and long sample compartment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10 mm path length\u003c\/li\u003e\n\u003cli\u003eUV quartz glass\u003c\/li\u003e\n\u003cli\u003e200–2500 nm\u003c\/li\u003e\n\u003cli\u003eThree polished windows\u003c\/li\u003e\n\u003cli\u003eSuitable for all Z dimensions\u003c\/li\u003e\n\u003cli\u003eLarge excitation and emission window area\u003c\/li\u003e\n\u003cli\u003e2 mm ID \/ 4 mm OD inlet-outlet tubes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #ddd;padding:14px 16px;\"\u003e\n\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"10 mm","offer_id":59796617068869,"sku":"SN71-F\/Q\/10","price":685.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna_71F_illustrative.jpg?v=1794253877"},{"product_id":"starna-type-18-micro-spectrophotometer-cell-10-mm-700-µl","title":"Starna Type 18 Micro Spectrophotometer Cell – 10 mm, 700 µL","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;line-height:1.6;color:#222;\"\u003e\n\u003ch2 style=\"color:#005f91;\"\u003eStarna Type 18 Micro Cell\u003c\/h2\u003e\n\u003cp\u003eMicro spectrophotometer cell with thickened side walls, 2 mm-wide sample chamber and two clear windows.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10 mm path length\u003c\/li\u003e\n\u003cli\u003e700 µL nominal volume\u003c\/li\u003e\n\u003cli\u003eTwo clear windows\u003c\/li\u003e\n\u003cli\u003eOpen top with non-sealing PTFE cover\u003c\/li\u003e\n\u003cli\u003eSuitable for spectrophotometers\u003c\/li\u003e\n\u003cli\u003eSpecified usable range: 320–2500 nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTechnical Document\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.analytics-shop.com\/media\/pdfs\/Starna_Type_18_cells.pdf\" target=\"_blank\" rel=\"noopener\" style=\"color:#005f91;font-weight:600;\"\u003eView Starna Type 18 data sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #ddd;padding:14px 16px;\"\u003e\n\u003ca href=\"\/pages\/contact\" style=\"color:#005f91;font-weight:600;\"\u003eContact Auckland Scientific for advice\u003c\/a\u003e.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Starna","offers":[{"title":"10 mm, 700 µL","offer_id":59796617265477,"sku":"SN18\/Q\/10","price":154.57,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/starna-type-18-micro-cell.jpg?v=1792269608"},{"product_id":"deuterium-d2-lamp-for-agilent-1260-1290-infinity-dad-8-pin-kild-agi-108ll","title":"Deuterium (D2) Lamp for Agilent 1260 \/ 1290 Infinity DAD (8 Pin) – KILD-AGI-108LL","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#233247;line-height:1.65\"\u003e\n\u003cdiv style=\"padding:26px 24px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 58%,#0a7b89 100%);color:#fff\"\u003e\n\u003cp style=\"margin:0 0 6px;color:#d8f4ff;font-size:13px;letter-spacing:.08em;text-transform:uppercase\"\u003eDeuterium Detector Lamp\u003c\/p\u003e\n\u003ch2 style=\"margin:0;color:#fff;font-size:30px\"\u003eDeuterium (D2) Lamp for Agilent 1260 \/ 1290 Infinity DAD (8 Pin) – KILD-AGI-108LL\u003c\/h2\u003e\n\u003cp style=\"margin:12px 0 0;color:#fff\"\u003eReplacement deuterium lamp for compatible analytical instruments and detector systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #cbd8e4;border-radius:9px\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;min-width:620px;font-size:14px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left;width:30%\"\u003eLamp brand\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAltmann Analytik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible instrument manufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent \/ HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible models\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent 1260; Agilent 1290 Infinity DAD (8 pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eEquivalent \/ reference numbers\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003e5190-0917; LD-AGI-108LL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eLifetime\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eLong-life lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eAuckland Scientific SKU\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eKILD-AGI-108LL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eProduct information\u003c\/h3\u003e\n\u003cp\u003eDeuterium lamps are used as stable UV light sources in HPLC detectors, UV\/VIS spectrophotometers and other analytical systems. This listing is intended as a replacement for the compatible instruments and reference numbers shown above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm your instrument model and existing lamp\/OEM number before ordering.\u003c\/strong\u003e If you are unsure, Auckland Scientific can help check compatibility before purchase.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eTechnical literature\u003c\/h3\u003e\n\u003cp\u003eSupporting technical information and available product literature can be supplied by Auckland Scientific on request.\u003c\/p\u003e\n\n\u003cdiv style=\"margin-top:24px;padding:20px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 100%);color:#fff\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#fff;font-size:22px\"\u003eNeed help identifying the correct lamp?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;color:#fff\"\u003eSend us the instrument manufacturer, model and current lamp or OEM reference number and we will help identify the most suitable replacement.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;padding:11px 17px;border-radius:7px;background:#fff;color:#075b82;text-decoration:none;font-weight:bold\"\u003eContact Auckland Scientific for compatibility advice\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top:18px;font-size:12px;color:#65758b\"\u003eCompatibility information is based on current supplier data. Images may differ slightly from the delivered lamp. Please confirm compatibility before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":59800432574789,"sku":"KILD-AGI-108LL","price":639.77,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/KILD-AGI-108LL.jpg?v=1792328091"},{"product_id":"deuterium-d2-lamp-for-agilent-1100-1200-1260-dad-kild-agi-105ll","title":"Deuterium (D2) Lamp for Agilent 1100 \/ 1200 \/ 1260 DAD – KILD-AGI-105LL","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#233247;line-height:1.65\"\u003e\n\u003cdiv style=\"padding:26px 24px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 58%,#0a7b89 100%);color:#fff\"\u003e\n\u003cp style=\"margin:0 0 6px;color:#d8f4ff;font-size:13px;letter-spacing:.08em;text-transform:uppercase\"\u003eDeuterium Detector Lamp\u003c\/p\u003e\n\u003ch2 style=\"margin:0;color:#fff;font-size:30px\"\u003eDeuterium (D2) Lamp for Agilent 1100 \/ 1200 \/ 1260 DAD – KILD-AGI-105LL\u003c\/h2\u003e\n\u003cp style=\"margin:12px 0 0;color:#fff\"\u003eReplacement deuterium lamp for compatible analytical instruments and detector systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #cbd8e4;border-radius:9px\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;min-width:620px;font-size:14px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left;width:30%\"\u003eLamp brand\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAltmann Analytik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible instrument manufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent \/ HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible models\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent 1100; Agilent 1200; Agilent 1260 DAD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eEquivalent \/ reference numbers\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003e5181-1530; 2140-0590; 2140-0813; LD-AGI-105LL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eLifetime\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eLong-life lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eAuckland Scientific SKU\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eKILD-AGI-105LL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eProduct information\u003c\/h3\u003e\n\u003cp\u003eDeuterium lamps are used as stable UV light sources in HPLC detectors, UV\/VIS spectrophotometers and other analytical systems. This listing is intended as a replacement for the compatible instruments and reference numbers shown above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm your instrument model and existing lamp\/OEM number before ordering.\u003c\/strong\u003e If you are unsure, Auckland Scientific can help check compatibility before purchase.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eTechnical literature\u003c\/h3\u003e\n\u003cp\u003eSupporting technical information and available product literature can be supplied by Auckland Scientific on request.\u003c\/p\u003e\n\n\u003cdiv style=\"margin-top:24px;padding:20px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 100%);color:#fff\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#fff;font-size:22px\"\u003eNeed help identifying the correct lamp?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;color:#fff\"\u003eSend us the instrument manufacturer, model and current lamp or OEM reference number and we will help identify the most suitable replacement.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;padding:11px 17px;border-radius:7px;background:#fff;color:#075b82;text-decoration:none;font-weight:bold\"\u003eContact Auckland Scientific for compatibility advice\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top:18px;font-size:12px;color:#65758b\"\u003eCompatibility information is based on current supplier data. Images may differ slightly from the delivered lamp. Please confirm compatibility before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":59800433066309,"sku":"KILD-AGI-105LL","price":639.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/KILD-AGI-105LL.jpg?v=1792328096"},{"product_id":"deuterium-lamp-for-agilent-1100-1200-dad-mwd-long-life-2140-0813asp","title":"Deuterium Lamp for Agilent 1100 \/ 1200 DAD-MWD – Long Life – 2140-0813ASP","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#233247;line-height:1.65\"\u003e\n\u003cdiv style=\"padding:26px 24px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 58%,#0a7b89 100%);color:#fff\"\u003e\n\u003cp style=\"margin:0 0 6px;color:#d8f4ff;font-size:13px;letter-spacing:.08em;text-transform:uppercase\"\u003eDeuterium Detector Lamp\u003c\/p\u003e\n\u003ch2 style=\"margin:0;color:#fff;font-size:30px\"\u003eDeuterium Lamp for Agilent 1100 \/ 1200 DAD-MWD – Long Life – 2140-0813ASP\u003c\/h2\u003e\n\u003cp style=\"margin:12px 0 0;color:#fff\"\u003eReplacement deuterium lamp for compatible analytical instruments and detector systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #cbd8e4;border-radius:9px\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;min-width:620px;font-size:14px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left;width:30%\"\u003eLamp brand\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAltmann Analytik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible instrument manufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible models\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent 1100; 1200; 1220; 1260; G1315A\/B; G1365A\/B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eEquivalent \/ reference numbers\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent 2140-0813\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eLifetime\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eLong-life lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eAuckland Scientific SKU\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003e2140-0813ASP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eProduct information\u003c\/h3\u003e\n\u003cp\u003eDeuterium lamps are used as stable UV light sources in HPLC detectors, UV\/VIS spectrophotometers and other analytical systems. This listing is intended as a replacement for the compatible instruments and reference numbers shown above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm your instrument model and existing lamp\/OEM number before ordering.\u003c\/strong\u003e If you are unsure, Auckland Scientific can help check compatibility before purchase.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eTechnical literature\u003c\/h3\u003e\n\u003cp\u003eSupporting technical information and available product literature can be supplied by Auckland Scientific on request.\u003c\/p\u003e\n\n\u003cdiv style=\"margin-top:24px;padding:20px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 100%);color:#fff\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#fff;font-size:22px\"\u003eNeed help identifying the correct lamp?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;color:#fff\"\u003eSend us the instrument manufacturer, model and current lamp or OEM reference number and we will help identify the most suitable replacement.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;padding:11px 17px;border-radius:7px;background:#fff;color:#075b82;text-decoration:none;font-weight:bold\"\u003eContact Auckland Scientific for compatibility advice\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top:18px;font-size:12px;color:#65758b\"\u003eCompatibility information is based on current supplier data. Images may differ slightly from the delivered lamp. Please confirm compatibility before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":59800433099077,"sku":"2140-0813ASP","price":879.38,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/2140-0813ASP.jpg?v=1792328101"},{"product_id":"deuterium-d2-lamp-for-agilent-8453-8454-uv-vis-spectrophotometers-2140-0605asp","title":"Deuterium (D2) Lamp for Agilent 8453 \/ 8454 UV-VIS Spectrophotometers – 2140-0605ASP","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#233247;line-height:1.65\"\u003e\n\u003cdiv style=\"padding:26px 24px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 58%,#0a7b89 100%);color:#fff\"\u003e\n\u003cp style=\"margin:0 0 6px;color:#d8f4ff;font-size:13px;letter-spacing:.08em;text-transform:uppercase\"\u003eDeuterium Detector Lamp\u003c\/p\u003e\n\u003ch2 style=\"margin:0;color:#fff;font-size:30px\"\u003eDeuterium (D2) Lamp for Agilent 8453 \/ 8454 UV-VIS Spectrophotometers – 2140-0605ASP\u003c\/h2\u003e\n\u003cp style=\"margin:12px 0 0;color:#fff\"\u003eReplacement deuterium lamp for compatible analytical instruments and detector systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #cbd8e4;border-radius:9px\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;min-width:620px;font-size:14px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left;width:30%\"\u003eLamp brand\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAltmann Analytik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible instrument manufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible models\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent 8453; Agilent 8454\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eEquivalent \/ reference numbers\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent 2140-0605\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eAuckland Scientific SKU\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003e2140-0605ASP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eProduct information\u003c\/h3\u003e\n\u003cp\u003eDeuterium lamps are used as stable UV light sources in HPLC detectors, UV\/VIS spectrophotometers and other analytical systems. This listing is intended as a replacement for the compatible instruments and reference numbers shown above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm your instrument model and existing lamp\/OEM number before ordering.\u003c\/strong\u003e If you are unsure, Auckland Scientific can help check compatibility before purchase.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eTechnical literature\u003c\/h3\u003e\n\u003cp\u003eSupporting technical information and available product literature can be supplied by Auckland Scientific on request.\u003c\/p\u003e\n\n\u003cdiv style=\"margin-top:24px;padding:20px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 100%);color:#fff\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#fff;font-size:22px\"\u003eNeed help identifying the correct lamp?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;color:#fff\"\u003eSend us the instrument manufacturer, model and current lamp or OEM reference number and we will help identify the most suitable replacement.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;padding:11px 17px;border-radius:7px;background:#fff;color:#075b82;text-decoration:none;font-weight:bold\"\u003eContact Auckland Scientific for compatibility advice\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top:18px;font-size:12px;color:#65758b\"\u003eCompatibility information is based on current supplier data. Images may differ slightly from the delivered lamp. Please confirm compatibility before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":59800433426757,"sku":"2140-0605ASP","price":707.72,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/2140-0605ASP.jpg?v=1792328107"},{"product_id":"deuterium-lamp-for-agilent-1100-1200-dad-mwd-2140-0590asp","title":"Deuterium Lamp for Agilent 1100 \/ 1200 DAD-MWD – 2140-0590ASP","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#233247;line-height:1.65\"\u003e\n\u003cdiv style=\"padding:26px 24px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 58%,#0a7b89 100%);color:#fff\"\u003e\n\u003cp style=\"margin:0 0 6px;color:#d8f4ff;font-size:13px;letter-spacing:.08em;text-transform:uppercase\"\u003eDeuterium Detector Lamp\u003c\/p\u003e\n\u003ch2 style=\"margin:0;color:#fff;font-size:30px\"\u003eDeuterium Lamp for Agilent 1100 \/ 1200 DAD-MWD – 2140-0590ASP\u003c\/h2\u003e\n\u003cp style=\"margin:12px 0 0;color:#fff\"\u003eReplacement deuterium lamp for compatible analytical instruments and detector systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #cbd8e4;border-radius:9px\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;min-width:620px;font-size:14px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left;width:30%\"\u003eLamp brand\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAltmann Analytik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible instrument manufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible models\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent 1100; Agilent 1200; G1315A\/B; G1365A\/B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eEquivalent \/ reference numbers\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent 2140-0590\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eAuckland Scientific SKU\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003e2140-0590ASP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eProduct information\u003c\/h3\u003e\n\u003cp\u003eDeuterium lamps are used as stable UV light sources in HPLC detectors, UV\/VIS spectrophotometers and other analytical systems. This listing is intended as a replacement for the compatible instruments and reference numbers shown above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm your instrument model and existing lamp\/OEM number before ordering.\u003c\/strong\u003e If you are unsure, Auckland Scientific can help check compatibility before purchase.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eTechnical literature\u003c\/h3\u003e\n\u003cp\u003eSupporting technical information and available product literature can be supplied by Auckland Scientific on request.\u003c\/p\u003e\n\n\u003cdiv style=\"margin-top:24px;padding:20px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 100%);color:#fff\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#fff;font-size:22px\"\u003eNeed help identifying the correct lamp?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;color:#fff\"\u003eSend us the instrument manufacturer, model and current lamp or OEM reference number and we will help identify the most suitable replacement.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;padding:11px 17px;border-radius:7px;background:#fff;color:#075b82;text-decoration:none;font-weight:bold\"\u003eContact Auckland Scientific for compatibility advice\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top:18px;font-size:12px;color:#65758b\"\u003eCompatibility information is based on current supplier data. Images may differ slightly from the delivered lamp. Please confirm compatibility before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":59800437915973,"sku":"2140-0590ASP","price":699.06,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/2140-0590ASP.jpg?v=1792328112"},{"product_id":"long-life-his-deuterium-lamp-with-rfid-for-agilent-vwd-g1314-60101asp","title":"Long Life HiS Deuterium Lamp with RFID for Agilent VWD – G1314-60101ASP","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#233247;line-height:1.65\"\u003e\n\u003cdiv style=\"padding:26px 24px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 58%,#0a7b89 100%);color:#fff\"\u003e\n\u003cp style=\"margin:0 0 6px;color:#d8f4ff;font-size:13px;letter-spacing:.08em;text-transform:uppercase\"\u003eDeuterium Detector Lamp\u003c\/p\u003e\n\u003ch2 style=\"margin:0;color:#fff;font-size:30px\"\u003eLong Life HiS Deuterium Lamp with RFID for Agilent VWD – G1314-60101ASP\u003c\/h2\u003e\n\u003cp style=\"margin:12px 0 0;color:#fff\"\u003eReplacement deuterium lamp for compatible analytical instruments and detector systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #cbd8e4;border-radius:9px\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;min-width:620px;font-size:14px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left;width:30%\"\u003eLamp brand\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAltmann Analytik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible instrument manufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible models\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent G1314D; G1314E; G1314F; G7114A; G7114B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eEquivalent \/ reference numbers\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent G1314-60101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eLifetime\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003e2000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eAuckland Scientific SKU\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eG1314-60101ASP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eProduct information\u003c\/h3\u003e\n\u003cp\u003eDeuterium lamps are used as stable UV light sources in HPLC detectors, UV\/VIS spectrophotometers and other analytical systems. This listing is intended as a replacement for the compatible instruments and reference numbers shown above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm your instrument model and existing lamp\/OEM number before ordering.\u003c\/strong\u003e If you are unsure, Auckland Scientific can help check compatibility before purchase.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eTechnical literature\u003c\/h3\u003e\n\u003cp\u003eSupporting technical information and available product literature can be supplied by Auckland Scientific on request.\u003c\/p\u003e\n\n\u003cdiv style=\"margin-top:24px;padding:20px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 100%);color:#fff\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#fff;font-size:22px\"\u003eNeed help identifying the correct lamp?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;color:#fff\"\u003eSend us the instrument manufacturer, model and current lamp or OEM reference number and we will help identify the most suitable replacement.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;padding:11px 17px;border-radius:7px;background:#fff;color:#075b82;text-decoration:none;font-weight:bold\"\u003eContact Auckland Scientific for compatibility advice\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top:18px;font-size:12px;color:#65758b\"\u003eCompatibility information is based on current supplier data. Images may differ slightly from the delivered lamp. Please confirm compatibility before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":59800440504645,"sku":"G1314-60101ASP","price":605.44,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/G1314-60101ASP.jpg?v=1792328117"},{"product_id":"long-life-deuterium-lamp-with-rfid-for-agilent-1220-1260-dad-2140-0820asp","title":"Long Life Deuterium Lamp with RFID for Agilent 1220 \/ 1260 DAD – 2140-0820ASP","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#233247;line-height:1.65\"\u003e\n\u003cdiv style=\"padding:26px 24px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 58%,#0a7b89 100%);color:#fff\"\u003e\n\u003cp style=\"margin:0 0 6px;color:#d8f4ff;font-size:13px;letter-spacing:.08em;text-transform:uppercase\"\u003eDeuterium Detector Lamp\u003c\/p\u003e\n\u003ch2 style=\"margin:0;color:#fff;font-size:30px\"\u003eLong Life Deuterium Lamp with RFID for Agilent 1220 \/ 1260 DAD – 2140-0820ASP\u003c\/h2\u003e\n\u003cp style=\"margin:12px 0 0;color:#fff\"\u003eReplacement deuterium lamp for compatible analytical instruments and detector systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #cbd8e4;border-radius:9px\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;min-width:620px;font-size:14px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left;width:30%\"\u003eLamp brand\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAltmann Analytik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible instrument manufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible models\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent 1220 Infinity LC; 1260; G1315C\/D; G1365C\/D; G7115A; G7165A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eEquivalent \/ reference numbers\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAgilent 2140-0820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eLifetime\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003e2000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eAuckland Scientific SKU\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003e2140-0820ASP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eProduct information\u003c\/h3\u003e\n\u003cp\u003eDeuterium lamps are used as stable UV light sources in HPLC detectors, UV\/VIS spectrophotometers and other analytical systems. This listing is intended as a replacement for the compatible instruments and reference numbers shown above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm your instrument model and existing lamp\/OEM number before ordering.\u003c\/strong\u003e If you are unsure, Auckland Scientific can help check compatibility before purchase.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eTechnical literature\u003c\/h3\u003e\n\u003cp\u003eSupporting technical information and available product literature can be supplied by Auckland Scientific on request.\u003c\/p\u003e\n\n\u003cdiv style=\"margin-top:24px;padding:20px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 100%);color:#fff\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#fff;font-size:22px\"\u003eNeed help identifying the correct lamp?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;color:#fff\"\u003eSend us the instrument manufacturer, model and current lamp or OEM reference number and we will help identify the most suitable replacement.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;padding:11px 17px;border-radius:7px;background:#fff;color:#075b82;text-decoration:none;font-weight:bold\"\u003eContact Auckland Scientific for compatibility advice\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top:18px;font-size:12px;color:#65758b\"\u003eCompatibility information is based on current supplier data. Images may differ slightly from the delivered lamp. Please confirm compatibility before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":59800441291077,"sku":"2140-0820ASP","price":1073.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/2140-0820ASP.jpg?v=1792328122"},{"product_id":"deuterium-lamp-for-perkinelmer-lambda-spectrophotometers-l6022728asp","title":"Deuterium Lamp for PerkinElmer Lambda Spectrophotometers – L6022728ASP","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#233247;line-height:1.65\"\u003e\n\u003cdiv style=\"padding:26px 24px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 58%,#0a7b89 100%);color:#fff\"\u003e\n\u003cp style=\"margin:0 0 6px;color:#d8f4ff;font-size:13px;letter-spacing:.08em;text-transform:uppercase\"\u003eDeuterium Detector Lamp\u003c\/p\u003e\n\u003ch2 style=\"margin:0;color:#fff;font-size:30px\"\u003eDeuterium Lamp for PerkinElmer Lambda Spectrophotometers – L6022728ASP\u003c\/h2\u003e\n\u003cp style=\"margin:12px 0 0;color:#fff\"\u003eReplacement deuterium lamp for compatible analytical instruments and detector systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #cbd8e4;border-radius:9px\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;min-width:620px;font-size:14px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left;width:30%\"\u003eLamp brand\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAltmann Analytik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible instrument manufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003ePerkinElmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible models\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eLambda 2, 5, 7, 9, 10, 11, 12, 14, 15, 16, 17, 18, 19, 20, 25, 35, 40, 45; BIO 19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eEquivalent \/ reference numbers\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003ePerkinElmer L6022728; old reference B0160917\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eLifetime\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003e1500 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eAuckland Scientific SKU\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eL6022728ASP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eProduct information\u003c\/h3\u003e\n\u003cp\u003eDeuterium lamps are used as stable UV light sources in HPLC detectors, UV\/VIS spectrophotometers and other analytical systems. This listing is intended as a replacement for the compatible instruments and reference numbers shown above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm your instrument model and existing lamp\/OEM number before ordering.\u003c\/strong\u003e If you are unsure, Auckland Scientific can help check compatibility before purchase.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eTechnical literature\u003c\/h3\u003e\n\u003cp\u003eSupporting technical information and available product literature can be supplied by Auckland Scientific on request.\u003c\/p\u003e\n\n\u003cdiv style=\"margin-top:24px;padding:20px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 100%);color:#fff\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#fff;font-size:22px\"\u003eNeed help identifying the correct lamp?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;color:#fff\"\u003eSend us the instrument manufacturer, model and current lamp or OEM reference number and we will help identify the most suitable replacement.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;padding:11px 17px;border-radius:7px;background:#fff;color:#075b82;text-decoration:none;font-weight:bold\"\u003eContact Auckland Scientific for compatibility advice\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top:18px;font-size:12px;color:#65758b\"\u003eCompatibility information is based on current supplier data. Images may differ slightly from the delivered lamp. Please confirm compatibility before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":59800441389381,"sku":"L6022728ASP","price":818.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/L6022728ASP.jpg?v=1792328127"},{"product_id":"long-life-deuterium-d2-lamp-for-hitachi-dad-detectors-892-2550asp","title":"Long Life Deuterium (D2) Lamp for Hitachi DAD Detectors – 892-2550ASP","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#233247;line-height:1.65\"\u003e\n\u003cdiv style=\"padding:26px 24px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 58%,#0a7b89 100%);color:#fff\"\u003e\n\u003cp style=\"margin:0 0 6px;color:#d8f4ff;font-size:13px;letter-spacing:.08em;text-transform:uppercase\"\u003eDeuterium Detector Lamp\u003c\/p\u003e\n\u003ch2 style=\"margin:0;color:#fff;font-size:30px\"\u003eLong Life Deuterium (D2) Lamp for Hitachi DAD Detectors – 892-2550ASP\u003c\/h2\u003e\n\u003cp style=\"margin:12px 0 0;color:#fff\"\u003eReplacement deuterium lamp for compatible analytical instruments and detector systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #cbd8e4;border-radius:9px\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;min-width:620px;font-size:14px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left;width:30%\"\u003eLamp brand\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAltmann Analytik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible instrument manufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eHitachi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible models\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eHitachi L-7400; L-7420; L-7450; L-2400; L-2450 DAD; L-7450A; L-7455\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eEquivalent \/ reference numbers\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eOEM 892-2550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eLifetime\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eLong-life lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eAuckland Scientific SKU\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003e892-2550ASP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eProduct information\u003c\/h3\u003e\n\u003cp\u003eDeuterium lamps are used as stable UV light sources in HPLC detectors, UV\/VIS spectrophotometers and other analytical systems. This listing is intended as a replacement for the compatible instruments and reference numbers shown above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm your instrument model and existing lamp\/OEM number before ordering.\u003c\/strong\u003e If you are unsure, Auckland Scientific can help check compatibility before purchase.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eTechnical literature\u003c\/h3\u003e\n\u003cp\u003eSupporting technical information and available product literature can be supplied by Auckland Scientific on request.\u003c\/p\u003e\n\n\u003cdiv style=\"margin-top:24px;padding:20px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 100%);color:#fff\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#fff;font-size:22px\"\u003eNeed help identifying the correct lamp?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;color:#fff\"\u003eSend us the instrument manufacturer, model and current lamp or OEM reference number and we will help identify the most suitable replacement.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;padding:11px 17px;border-radius:7px;background:#fff;color:#075b82;text-decoration:none;font-weight:bold\"\u003eContact Auckland Scientific for compatibility advice\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top:18px;font-size:12px;color:#65758b\"\u003eCompatibility information is based on current supplier data. Images may differ slightly from the delivered lamp. Please confirm compatibility before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":59800441454917,"sku":"892-2550ASP","price":852.96,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/892-2550ASP.jpg?v=1792328133"},{"product_id":"long-life-deuterium-d2-lamp-for-dionex-ultimate-3000-3100-3400-kild-dio-105ll","title":"Long Life Deuterium (D2) Lamp for Dionex Ultimate 3000 \/ 3100 \/ 3400 – KILD-DIO-105LL","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#233247;line-height:1.65\"\u003e\n\u003cdiv style=\"padding:26px 24px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 58%,#0a7b89 100%);color:#fff\"\u003e\n\u003cp style=\"margin:0 0 6px;color:#d8f4ff;font-size:13px;letter-spacing:.08em;text-transform:uppercase\"\u003eDeuterium Detector Lamp\u003c\/p\u003e\n\u003ch2 style=\"margin:0;color:#fff;font-size:30px\"\u003eLong Life Deuterium (D2) Lamp for Dionex Ultimate 3000 \/ 3100 \/ 3400 – KILD-DIO-105LL\u003c\/h2\u003e\n\u003cp style=\"margin:12px 0 0;color:#fff\"\u003eReplacement deuterium lamp for compatible analytical instruments and detector systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #cbd8e4;border-radius:9px\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;min-width:620px;font-size:14px\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left;width:30%\"\u003eLamp brand\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAltmann Analytik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible instrument manufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eDionex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible models\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eUltiMate DAD 3000; MWD 3000 \/ 3000RS; DAD 3000RS; VWD 3000 \/ 3100 \/ 3400 \/ 3400RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eEquivalent \/ reference numbers\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eDionex 6074.1110; L6999-52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eLifetime\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003e2000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eAuckland Scientific SKU\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eKILD-DIO-105LL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eProduct information\u003c\/h3\u003e\n\u003cp\u003eDeuterium lamps are used as stable UV light sources in HPLC detectors, UV\/VIS spectrophotometers and other analytical systems. This listing is intended as a replacement for the compatible instruments and reference numbers shown above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm your instrument model and existing lamp\/OEM number before ordering.\u003c\/strong\u003e If you are unsure, Auckland Scientific can help check compatibility before purchase.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eTechnical literature\u003c\/h3\u003e\n\u003cp\u003eSupporting technical information and available product literature can be supplied by Auckland Scientific on request.\u003c\/p\u003e\n\n\u003cdiv style=\"margin-top:24px;padding:20px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 100%);color:#fff\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#fff;font-size:22px\"\u003eNeed help identifying the correct lamp?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;color:#fff\"\u003eSend us the instrument manufacturer, model and current lamp or OEM reference number and we will help identify the most suitable replacement.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;padding:11px 17px;border-radius:7px;background:#fff;color:#075b82;text-decoration:none;font-weight:bold\"\u003eContact Auckland Scientific for compatibility advice\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top:18px;font-size:12px;color:#65758b\"\u003eCompatibility information is based on current supplier data. Images may differ slightly from the delivered lamp. Please confirm compatibility before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":59800441585989,"sku":"KILD-DIO-105LL","price":1073.57,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/KILD-DIO-105LL.jpg?v=1792328138"},{"product_id":"long-life-deuterium-d2-lamp-for-waters-2487-2488-kild-wat-105ll","title":"Long Life Deuterium (D2) Lamp for Waters 2487 \/ 2488 – KILD-WAT-105LL","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#233247;line-height:1.65\"\u003e\n\u003cdiv style=\"padding:26px 24px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 58%,#0a7b89 100%);color:#fff\"\u003e\n\u003cp style=\"margin:0 0 6px;color:#d8f4ff;font-size:13px;letter-spacing:.08em;text-transform:uppercase\"\u003eDeuterium Detector Lamp\u003c\/p\u003e\n\u003ch2 style=\"margin:0;color:#fff;font-size:30px\"\u003eLong Life Deuterium (D2) Lamp for Waters 2487 \/ 2488 – KILD-WAT-105LL\u003c\/h2\u003e\n\u003cp style=\"margin:12px 0 0;color:#fff\"\u003eReplacement deuterium lamp for compatible analytical instruments and detector systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #cbd8e4;border-radius:9px\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;min-width:620px;font-size:14px\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left;width:30%\"\u003eLamp brand\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eAltmann Analytik\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible instrument manufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eWaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible models\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eWaters 2487 Dual Wavelength; Waters 2488 Dual Wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eEquivalent \/ reference numbers\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eWAT081142; LD-WAT-105LL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eGuaranteed \/ stated lifetime\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003e2000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eSKU\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eKILD-WAT-105LL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eProduct information\u003c\/h3\u003e\n\u003cp\u003eDeuterium lamps provide a stable UV source for compatible HPLC detectors, UV\/VIS spectrophotometers and related analytical instruments. This listing is intended for the instrument models and reference numbers shown above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm the instrument model and current lamp\/OEM number before ordering.\u003c\/strong\u003e Compatibility can vary between detector revisions and connector types.\u003c\/p\u003e\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eTechnical literature\u003c\/h3\u003e\n\u003cp\u003eSupporting technical information and available product literature can be supplied by Auckland Scientific on request.\u003c\/p\u003e\n\u003cdiv style=\"margin-top:24px;padding:20px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 100%);color:#fff\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#fff;font-size:22px\"\u003eNeed help identifying the correct lamp?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;color:#fff\"\u003eSend us your instrument manufacturer, model and current lamp or OEM reference number and we will help identify the correct replacement.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;padding:11px 17px;border-radius:7px;background:#fff;color:#075b82;text-decoration:none;font-weight:bold\"\u003eContact Auckland Scientific for compatibility advice\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top:18px;font-size:12px;color:#65758b\"\u003eCompatibility information is based on current supplier data. Images may differ slightly from the delivered lamp. Please confirm compatibility before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":59800543920453,"sku":"KILD-WAT-105LL","price":716.77,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/KILD-WAT-105LL.jpg?v=1792328546"},{"product_id":"excelitas-deuterium-d2-lamp-sd-1241-01-j-for-thermo-ice-m-s-series-hn80119072","title":"Excelitas Deuterium (D2) Lamp SD 1241-01 J for Thermo iCE \/ M \/ S Series – HN80119072","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#233247;line-height:1.65\"\u003e\n\u003cdiv style=\"padding:26px 24px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 58%,#0a7b89 100%);color:#fff\"\u003e\n\u003cp style=\"margin:0 0 6px;color:#d8f4ff;font-size:13px;letter-spacing:.08em;text-transform:uppercase\"\u003eDeuterium Detector Lamp\u003c\/p\u003e\n\u003ch2 style=\"margin:0;color:#fff;font-size:30px\"\u003eExcelitas Deuterium (D2) Lamp SD 1241-01 J for Thermo iCE \/ M \/ S Series – HN80119072\u003c\/h2\u003e\n\u003cp style=\"margin:12px 0 0;color:#fff\"\u003eReplacement deuterium lamp for compatible analytical instruments and detector systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #cbd8e4;border-radius:9px\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;min-width:620px;font-size:14px\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left;width:30%\"\u003eLamp brand\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eExcelitas Noblelight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible instrument manufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eThermo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eCompatible models\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eThermo iCE 3300 AAS; M Series (newer series); S Series; SOLAAR S4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eEquivalent \/ reference numbers\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eThermo 9423 420 30004; lamp type SD 1241-01 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003cth style=\"padding:9px;border:1px solid #cbd8e4;background:#f2f6f9;text-align:left\"\u003eSKU\u003c\/th\u003e\n\u003ctd style=\"padding:9px;border:1px solid #cbd8e4\"\u003eHN80119072\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eProduct information\u003c\/h3\u003e\n\u003cp\u003eDeuterium lamps provide a stable UV source for compatible HPLC detectors, UV\/VIS spectrophotometers and related analytical instruments. This listing is intended for the instrument models and reference numbers shown above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease confirm the instrument model and current lamp\/OEM number before ordering.\u003c\/strong\u003e Compatibility can vary between detector revisions and connector types.\u003c\/p\u003e\n\u003ch3 style=\"margin:24px 0 10px;padding:10px 14px;background:#075b82;color:#fff;border-radius:7px;font-size:20px\"\u003eTechnical literature\u003c\/h3\u003e\n\u003cp\u003eSupporting technical information and available product literature can be supplied by Auckland Scientific on request.\u003c\/p\u003e\n\u003cdiv style=\"margin-top:24px;padding:20px;border-radius:12px;background:linear-gradient(125deg,#102a43 0%,#075b82 100%);color:#fff\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#fff;font-size:22px\"\u003eNeed help identifying the correct lamp?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;color:#fff\"\u003eSend us your instrument manufacturer, model and current lamp or OEM reference number and we will help identify the correct replacement.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;padding:11px 17px;border-radius:7px;background:#fff;color:#075b82;text-decoration:none;font-weight:bold\"\u003eContact Auckland Scientific for compatibility advice\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top:18px;font-size:12px;color:#65758b\"\u003eCompatibility information is based on current supplier data. Images may differ slightly from the delivered lamp. Please confirm compatibility before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Excelitas","offers":[{"title":"Default Title","offer_id":59800546771269,"sku":"HN80119072","price":628.13,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/HN80119072.jpg?v=1792328554"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/collections\/microscope_cuvettes_e61d6a07-d38a-4811-922f-acb60bf14344.jpg?v=1781348029","url":"https:\/\/auckland-scientific.co.uk\/collections\/spectrophotometer-consumables.oembed?page=4","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}