{"title":"Vibration Isolation Systems","description":"\u003cp\u003ePassive vibration isolation workstations, pneumatic isolators, platforms and anti-vibration tables for laboratory and precision instruments. Includes DAEIL SYSTEMS passive products and Auckland Scientific anti-vibration tables.\u003c\/p\u003e","products":[{"product_id":"anti-vibration-table","title":"Anti Vibration Table","description":"\u003cp\u003e\u003cspan\u003eErgonomically styled, the AVT offers a solid, stable surface developed specifically to help decrease vibration during measurement. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen used in tandem with a balance or microscope, the table allows the balance to perform with marked precision, despite air currents or movements that might cause readings or optical precision to fluctuate. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe AVT is easy to assemble, with all necessary tools supplied. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe internal working surface measures 400 X 450mm, allowing ample space for a balances and microscopes. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts large, scratch-resistant dark granite slab sits on shock-absorbing rubber mounts, while leveling feet accommodate uneven surfaces. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe equipment fits in the middle of the AVT's granite surface, stabilizing the base and enabling greater precision.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eComes complete with \u003cstrong\u003e5 years warranty\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"features-wrapper__header\"\u003e\n\u003ch2\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"features-wrapper__columns\"\u003e\n\u003cdiv class=\"txtcols col-sm-6\"\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable levelling feet help optimise setup\u003c\/li\u003e\n\u003cli\u003e400 x 450mm granite block fits all Adam laboratory balances\u003c\/li\u003e\n\u003cli\u003eHigh-density granite and shock absorbing mounts ensure stability and minimise vibration\u003c\/li\u003e\n\u003cli\u003ePolished surface provides a flat, smooth area for accurate measurements\u003c\/li\u003e\n\u003cli\u003eScratch-resistant finish maintains the integrity of the surface over time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"txtcols col-sm-6\"\u003e\n\u003cul\u003e\n\u003cli\u003eNon-porous surface for easy cleaning\u003c\/li\u003e\n\u003cli\u003e800 x 600mm laminated work surface\u003c\/li\u003e\n\u003cli\u003eLightweight tubular aluminium frame\u003c\/li\u003e\n\u003cli\u003eA 5-year warranty means quality assured for years of use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":58276823892293,"sku":null,"price":1015.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/antivibrationtable.jpg?v=1781523222"},{"product_id":"daeil-dvid-l-passive-vibration-isolation-lab-workstation","title":"DAEIL DVID-L Passive Vibration Isolation Lab Workstation","description":"\u003ch2 style=\"color:#005f91;\"\u003eDAEIL DVID-L Passive Vibration Isolation Lab Workstation\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDVID-L\u003c\/strong\u003e is an all-in-one laboratory workstation combining a pneumatically isolated precision work surface with an ergonomic operator workspace. It is particularly useful where sensitive microscopy, inspection or measurement equipment must sit close to computers, controllers and other peripherals without allowing those items to feed vibration back into the instrument.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eWhy Choose the DVID-L?\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecoupled workspace:\u003c\/strong\u003e the auxiliary side workspace can be mechanically separated from the vibration-isolated zone, allowing computers, monitors and power supplies to remain close to the operator without disturbing the instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErgonomic operation:\u003c\/strong\u003e open-front frame and available front armrest support seated work and delicate manual adjustments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom engineered:\u003c\/strong\u003e width, depth, workspace position and heavy-duty configuration can be adapted around the equipment footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated mobility:\u003c\/strong\u003e casters allow positioning while the levelling system establishes the working height.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eIsolation Performance\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003ePneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eHigh-precision configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e1.5–3 Hz natural frequency; 80–99% isolation at 10 Hz; up to 300 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eDynamic-stability configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e4–8 Hz natural frequency; 80–99% isolation at 20 Hz; up to 600 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eLevelling repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e±1.0 mm standard; optional ±0.05 mm precision levelling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;\"\u003e\u003cstrong\u003eAir supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e4–6 bar, 10 L\/min, Ø6 mm pneumatic fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTypical Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOptical and research microscopes\u003c\/li\u003e\n\u003cli\u003eWhite-light interferometry and surface metrology\u003c\/li\u003e\n\u003cli\u003eProbe stations and semiconductor inspection\u003c\/li\u003e\n\u003cli\u003eMicrobalances and precision weighing\u003c\/li\u003e\n\u003cli\u003eCell injection and manipulation\u003c\/li\u003e\n\u003cli\u003eOptical lithography and fine positioning experiments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration note:\u003c\/strong\u003e DVID-L systems are custom-engineered. Please provide the instrument footprint, total load and preferred workspace arrangement when requesting a quotation.\u003c\/p\u003e\u003cdiv style=\"border-left:4px solid #005f91;background:#eef7fb;padding:16px;margin:20px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help selecting the correct configuration?\u003c\/strong\u003e\u003cp\u003eSend Auckland Scientific your instrument model, footprint, weight and installation conditions. We can help select the appropriate DAEIL configuration and provide a quotation.\u003c\/p\u003e\n\u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eRequest a Quote\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv style=\"border:1px solid #d6e5ed;background:#f7fbfd;padding:16px;margin:20px 0;border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#005f91;\"\u003eOfficial DAEIL Literature\u003c\/strong\u003e\n  \u003cp\u003eOfficial DAEIL SYSTEMS product literature covering the passive vibration-isolation range, specifications and applications.\u003c\/p\u003e\n  \u003ca href=\"https:\/\/www.daeilsys.com\/support\/resources\/catalogs\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eView DAEIL Product Catalog\u003c\/a\u003e\n  \u003c\/div\u003e\u003cdiv data-auckland-quote-block=\"true\" style=\"border:2px solid #005f91;background:#eef7fb;padding:18px;margin:24px 0;border-radius:6px;\"\u003e\n  \u003ch3 style=\"color:#005f91;margin-top:0;\"\u003eRequest a Quote\u003c\/h3\u003e\n  \u003cp\u003eThis product is supplied on a quotation basis. Contact Auckland Scientific with your application, required specification and delivery location and we will provide advice and pricing.\u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eSend an Enquiry\u003c\/a\u003e\n    \u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk?subject=Quote%20request%3A%20DAEIL%20DVID-L%20Passive%20Vibration%20Isolation%20Lab%20Workstation\u0026amp;body=Hello%20Michael%2C%0A%0AI%20would%20like%20a%20quotation%20for%20DAEIL%20DVID-L%20Passive%20Vibration%20Isolation%20Lab%20Workstation.%0A%0APlease%20contact%20me%20to%20discuss%20my%20requirements.%0A%0AName%3A%0ACompany%3A%0ATelephone%3A%0ADelivery%20location%3A%0AApplication%20%2F%20specification%20required%3A%0A\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eEmail Michael\u003c\/a\u003e\n    \u003ca href=\"tel:+447853690001\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 0 8px 0;\"\u003eCall 07853 690001\u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp style=\"margin-bottom:0;\"\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e michael.hallewell@auckland-scientific.co.uk\u003cbr\u003e\u003cstrong\u003eTelephone:\u003c\/strong\u003e 07853 690001\u003c\/p\u003e\n\u003c\/div\u003e","brand":"DAEIL SYSTEMS","offers":[{"title":"Integrated Armrest","offer_id":59793580654917,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true},{"title":"Separated Workspace","offer_id":59793580687685,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/dvid-l.webp?v=1792245951"},{"product_id":"daeil-dvid-c-cleanroom-vibration-isolation-workstation","title":"DAEIL DVID-C Cleanroom Vibration Isolation Workstation","description":"\u003ch2 style=\"color:#005f91;\"\u003eDAEIL DVID-C Cleanroom Vibration Isolation Workstation\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDVID-C\u003c\/strong\u003e is an all-stainless-steel pneumatic isolation workstation for cleanroom and contamination-sensitive precision measurement environments. It combines the vibration performance of the DVID workstation platform with 304-series stainless-steel construction and an ergonomic operator layout.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eCleanroom-Focused Design\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e304-series stainless-steel frame and work surfaces for cleanroom compatibility and easy cleaning.\u003c\/li\u003e\n\u003cli\u003eIntegrated armrest or separated-workspace architecture depending on operator workflow.\u003c\/li\u003e\n\u003cli\u003eMechanically separated side workspace can hold monitors, computers and peripherals without coupling their vibration into the isolated instrument zone.\u003c\/li\u003e\n\u003cli\u003eIntegrated casters and pneumatic levelling simplify positioning and setup.\u003c\/li\u003e\n\u003cli\u003eCustom dimensions are available to suit instrument footprint and facility constraints.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eIsolation Performance\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003ePneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eHigh-precision configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e1.5–3 Hz; 80–99% isolation at 10 Hz; up to 300 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eDynamic-stability configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e4–8 Hz; 80–99% isolation at 20 Hz; up to 600 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eLevelling repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e±1.0 mm standard; optional ±0.05 mm precision levelling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;\"\u003e\u003cstrong\u003eRequired air\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e4–6 bar, 10 L\/min, Ø6 mm fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eSuitable For\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCleanroom microscopy and optical metrology\u003c\/li\u003e\n\u003cli\u003eSemiconductor and display inspection\u003c\/li\u003e\n\u003cli\u003eProfilometry and surface measurement\u003c\/li\u003e\n\u003cli\u003eProbe stations and precision stages\u003c\/li\u003e\n\u003cli\u003eApplications where particle control and corrosion resistance matter\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"border-left:4px solid #005f91;background:#eef7fb;padding:16px;margin:20px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help selecting the correct configuration?\u003c\/strong\u003e\u003cp\u003eSend Auckland Scientific your instrument model, footprint, weight and installation conditions. We can help select the appropriate DAEIL configuration and provide a quotation.\u003c\/p\u003e\n\u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eRequest a Quote\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv style=\"border:1px solid #d6e5ed;background:#f7fbfd;padding:16px;margin:20px 0;border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#005f91;\"\u003eOfficial DAEIL Literature\u003c\/strong\u003e\n  \u003cp\u003eOfficial DAEIL SYSTEMS product literature covering the passive vibration-isolation range, specifications and applications.\u003c\/p\u003e\n  \u003ca href=\"https:\/\/www.daeilsys.com\/support\/resources\/catalogs\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eView DAEIL Product Catalog\u003c\/a\u003e\n  \u003c\/div\u003e\u003cdiv data-auckland-quote-block=\"true\" style=\"border:2px solid #005f91;background:#eef7fb;padding:18px;margin:24px 0;border-radius:6px;\"\u003e\n  \u003ch3 style=\"color:#005f91;margin-top:0;\"\u003eRequest a Quote\u003c\/h3\u003e\n  \u003cp\u003eThis product is supplied on a quotation basis. Contact Auckland Scientific with your application, required specification and delivery location and we will provide advice and pricing.\u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eSend an Enquiry\u003c\/a\u003e\n    \u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk?subject=Quote%20request%3A%20DAEIL%20DVID-C%20Cleanroom%20Vibration%20Isolation%20Workstation\u0026amp;body=Hello%20Michael%2C%0A%0AI%20would%20like%20a%20quotation%20for%20DAEIL%20DVID-C%20Cleanroom%20Vibration%20Isolation%20Workstation.%0A%0APlease%20contact%20me%20to%20discuss%20my%20requirements.%0A%0AName%3A%0ACompany%3A%0ATelephone%3A%0ADelivery%20location%3A%0AApplication%20%2F%20specification%20required%3A%0A\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eEmail Michael\u003c\/a\u003e\n    \u003ca href=\"tel:+447853690001\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 0 8px 0;\"\u003eCall 07853 690001\u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp style=\"margin-bottom:0;\"\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e michael.hallewell@auckland-scientific.co.uk\u003cbr\u003e\u003cstrong\u003eTelephone:\u003c\/strong\u003e 07853 690001\u003c\/p\u003e\n\u003c\/div\u003e","brand":"DAEIL SYSTEMS","offers":[{"title":"Integrated Armrest","offer_id":59793582063941,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true},{"title":"Separated Workspace","offer_id":59793582096709,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/dvid-c.webp?v=1792245974"},{"product_id":"daeil-dvid-h-optical-vibration-isolation-workstation","title":"DAEIL DVID-H Optical Vibration Isolation Workstation","description":"\u003ch2 style=\"color:#005f91;\"\u003eDAEIL DVID-H Optical Vibration Isolation Workstation\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDVID-H\u003c\/strong\u003e brings the rigidity and mounting flexibility of a honeycomb optical breadboard into a compact pneumatic workstation. It is designed for microscopy, interferometry, optical experiments and precision inspection where a full-size optical table is unnecessary but a rigid M6 mounting surface and effective floor-vibration isolation are required.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eHigh-Rigidity Optical Surface\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSteel honeycomb-core breadboard for high stiffness and broadband damping.\u003c\/li\u003e\n\u003cli\u003e430-series ferromagnetic stainless-steel working surface.\u003c\/li\u003e\n\u003cli\u003eM6 × 1.0 mounting holes, with 1\/4-20 available, on a 25 mm \/ 1 inch grid.\u003c\/li\u003e\n\u003cli\u003e37.5 mm edge distance and ±0.03 mm surface-flatness specification.\u003c\/li\u003e\n\u003cli\u003eSuitable for magnetic optical mounting and repeatable component positioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eWorkstation Design\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOpen-front welded tie-bar frame for seated operation.\u003c\/li\u003e\n\u003cli\u003eIntegrated casters for positioning.\u003c\/li\u003e\n\u003cli\u003eOptional armrests, monitor arms, sliding keyboard shelves, overhead racks and power-distribution accessories.\u003c\/li\u003e\n\u003cli\u003eCustom tabletop geometry, cable through-holes and non-standard load distributions can be engineered to order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eIsolation Performance\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eHigh-precision isolator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e1.5–3.0 Hz; 80–99% isolation at 10 Hz; up to 500 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eDynamic-stability isolator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e4.0–8.0 Hz; 80–99% isolation at 20 Hz; up to 600 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eLevelling repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e±1.0 mm standard; optional ±0.05 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;\"\u003e\u003cstrong\u003eAir supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e4–6 bar, 10 L\/min, Ø6 mm fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTypical Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eResearch and inspection microscopy\u003c\/li\u003e\n\u003cli\u003eInterferometry and optical metrology\u003c\/li\u003e\n\u003cli\u003eWafer and semiconductor inspection\u003c\/li\u003e\n\u003cli\u003eProbe stations and mask alignment\u003c\/li\u003e\n\u003cli\u003eHolography, laser experiments and precision optical assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"border-left:4px solid #005f91;background:#eef7fb;padding:16px;margin:20px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help selecting the correct configuration?\u003c\/strong\u003e\u003cp\u003eSend Auckland Scientific your instrument model, footprint, weight and installation conditions. We can help select the appropriate DAEIL configuration and provide a quotation.\u003c\/p\u003e\n\u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eRequest a Quote\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv style=\"border:1px solid #d6e5ed;background:#f7fbfd;padding:16px;margin:20px 0;border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#005f91;\"\u003eOfficial DAEIL Literature\u003c\/strong\u003e\n  \u003cp\u003eOfficial DAEIL SYSTEMS product literature covering the passive vibration-isolation range, specifications and applications.\u003c\/p\u003e\n  \u003ca href=\"https:\/\/www.daeilsys.com\/support\/resources\/catalogs\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eView DAEIL Product Catalog\u003c\/a\u003e\n  \u003c\/div\u003e\u003cdiv data-auckland-quote-block=\"true\" style=\"border:2px solid #005f91;background:#eef7fb;padding:18px;margin:24px 0;border-radius:6px;\"\u003e\n  \u003ch3 style=\"color:#005f91;margin-top:0;\"\u003eRequest a Quote\u003c\/h3\u003e\n  \u003cp\u003eThis product is supplied on a quotation basis. Contact Auckland Scientific with your application, required specification and delivery location and we will provide advice and pricing.\u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eSend an Enquiry\u003c\/a\u003e\n    \u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk?subject=Quote%20request%3A%20DAEIL%20DVID-H%20Optical%20Vibration%20Isolation%20Workstation\u0026amp;body=Hello%20Michael%2C%0A%0AI%20would%20like%20a%20quotation%20for%20DAEIL%20DVID-H%20Optical%20Vibration%20Isolation%20Workstation.%0A%0APlease%20contact%20me%20to%20discuss%20my%20requirements.%0A%0AName%3A%0ACompany%3A%0ATelephone%3A%0ADelivery%20location%3A%0AApplication%20%2F%20specification%20required%3A%0A\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eEmail Michael\u003c\/a\u003e\n    \u003ca href=\"tel:+447853690001\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 0 8px 0;\"\u003eCall 07853 690001\u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp style=\"margin-bottom:0;\"\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e michael.hallewell@auckland-scientific.co.uk\u003cbr\u003e\u003cstrong\u003eTelephone:\u003c\/strong\u003e 07853 690001\u003c\/p\u003e\n\u003c\/div\u003e","brand":"DAEIL SYSTEMS","offers":[{"title":"High-precision (1.5–3 Hz)","offer_id":59793583440197,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true},{"title":"Dynamic stability (4–8 Hz)","offer_id":59793583472965,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/dvid-h.webp?v=1792245985"},{"product_id":"daeil-dvid-t-passive-tabletop-vibration-isolation-workstation","title":"DAEIL DVID-T Passive Tabletop Vibration Isolation Workstation","description":"\u003ch2 style=\"color:#005f91;\"\u003eDAEIL DVID-T Passive Tabletop Vibration Isolation Workstation\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDVID-T\u003c\/strong\u003e is a compact, self-contained passive isolation platform for bench-mounted instruments. Unlike pneumatic systems, it uses a metal-spring suspension and requires \u003cstrong\u003eno compressed air and no electrical supply\u003c\/strong\u003e, making it straightforward to install or relocate.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAnodised AL6061 aluminium top and bottom plates provide a rigid but relatively lightweight platform.\u003c\/li\u003e\n\u003cli\u003eOptional M6 tapped mounting matrix for securing optical or measurement components.\u003c\/li\u003e\n\u003cli\u003eIntegrated level gauge and three manual levelers allow straightforward setup on an existing bench.\u003c\/li\u003e\n\u003cli\u003eUtility-free passive operation: no compressor, hoses or power connection.\u003c\/li\u003e\n\u003cli\u003eCompact dimensions suit laboratories where a full workstation would occupy too much floor space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003ePerformance\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003eMetal spring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eNatural frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e4–6 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation at 10 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e20–50%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;\"\u003e\u003cstrong\u003eMaximum payload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e90 kg standard; optional 150 kg configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAvailable Sizes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDVID-T45 — 400 × 500 × 115 mm\u003c\/li\u003e\n\u003cli\u003eDVID-T56 — 500 × 600 × 115 mm\u003c\/li\u003e\n\u003cli\u003eDVID-T67 — 600 × 700 × 115 mm\u003c\/li\u003e\n\u003cli\u003eDVID-T78 — 700 × 800 × 115 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTypical Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOptical microscopes and compact imaging systems\u003c\/li\u003e\n\u003cli\u003ePrecision balances\u003c\/li\u003e\n\u003cli\u003eSmall probe stations and metrology equipment\u003c\/li\u003e\n\u003cli\u003eBench-top optical experiments\u003c\/li\u003e\n\u003cli\u003eApplications needing a portable passive solution without compressed air\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"border-left:4px solid #005f91;background:#eef7fb;padding:16px;margin:20px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help selecting the correct configuration?\u003c\/strong\u003e\u003cp\u003eSend Auckland Scientific your instrument model, footprint, weight and installation conditions. We can help select the appropriate DAEIL configuration and provide a quotation.\u003c\/p\u003e\n\u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eRequest a Quote\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv style=\"border:1px solid #d6e5ed;background:#f7fbfd;padding:16px;margin:20px 0;border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#005f91;\"\u003eOfficial DAEIL Literature\u003c\/strong\u003e\n  \u003cp\u003eOfficial DAEIL SYSTEMS product literature covering the passive vibration-isolation range, specifications and applications.\u003c\/p\u003e\n  \u003ca href=\"https:\/\/www.daeilsys.com\/support\/resources\/catalogs\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eView DAEIL Product Catalog\u003c\/a\u003e\n  \u003c\/div\u003e\u003cdiv data-auckland-quote-block=\"true\" style=\"border:2px solid #005f91;background:#eef7fb;padding:18px;margin:24px 0;border-radius:6px;\"\u003e\n  \u003ch3 style=\"color:#005f91;margin-top:0;\"\u003eRequest a Quote\u003c\/h3\u003e\n  \u003cp\u003eThis product is supplied on a quotation basis. Contact Auckland Scientific with your application, required specification and delivery location and we will provide advice and pricing.\u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eSend an Enquiry\u003c\/a\u003e\n    \u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk?subject=Quote%20request%3A%20DAEIL%20DVID-T%20Passive%20Tabletop%20Vibration%20Isolation%20Workstation\u0026amp;body=Hello%20Michael%2C%0A%0AI%20would%20like%20a%20quotation%20for%20DAEIL%20DVID-T%20Passive%20Tabletop%20Vibration%20Isolation%20Workstation.%0A%0APlease%20contact%20me%20to%20discuss%20my%20requirements.%0A%0AName%3A%0ACompany%3A%0ATelephone%3A%0ADelivery%20location%3A%0AApplication%20%2F%20specification%20required%3A%0A\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eEmail Michael\u003c\/a\u003e\n    \u003ca href=\"tel:+447853690001\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 0 8px 0;\"\u003eCall 07853 690001\u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp style=\"margin-bottom:0;\"\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e michael.hallewell@auckland-scientific.co.uk\u003cbr\u003e\u003cstrong\u003eTelephone:\u003c\/strong\u003e 07853 690001\u003c\/p\u003e\n\u003c\/div\u003e","brand":"DAEIL SYSTEMS","offers":[{"title":"DVID-T45 — 400 × 500 × 115 mm","offer_id":59793584685381,"sku":"DVID-T45","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVID-T56 — 500 × 600 × 115 mm","offer_id":59793584718149,"sku":"DVID-T56","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVID-T67 — 600 × 700 × 115 mm","offer_id":59793584750917,"sku":"DVID-T67","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVID-T78 — 700 × 800 × 115 mm","offer_id":59793584783685,"sku":"DVID-T78","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/dvid-t.webp?v=1792245963"},{"product_id":"daeil-dvim-g-advanced-pneumatic-vibration-isolator","title":"DAEIL DVIM-G Advanced Pneumatic Vibration Isolator","description":"\u003ch2 style=\"color:#005f91;\"\u003eDAEIL DVIM-G Advanced Pneumatic Vibration Isolator\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDVIM-G\u003c\/strong\u003e is DAEIL's high-performance pneumatic isolator for precision metrology, inspection equipment and machinery with moving payloads. Its dual-chamber damping arrangement is designed to combine low-frequency isolation with faster recovery after stage movement.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eAdvanced Damping System\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual chamber:\u003c\/strong\u003e separate air and damping chambers are linked through precision orifices to dissipate energy generated by moving payloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable response:\u003c\/strong\u003e the damping response can be tuned to the application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir-operated valve option:\u003c\/strong\u003e increases pneumatic response speed during dynamic events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal oil damper option:\u003c\/strong\u003e provides additional damping where rapid stage movement or high inertial forces are present.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision levelling:\u003c\/strong\u003e optional ±0.05 mm repeatability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003ePerformance\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003ePneumatic, dual-chamber damping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eNatural frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e1.5–3.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation at 5 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e80–90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation at 10 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e90–99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;\"\u003e\u003cstrong\u003eModel capacities\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e500–6,000 kg maximum payload per isolator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eOrdering Information\u003c\/h3\u003e\u003cp\u003eModels range from DVIM-G-500 through DVIM-G-6000. Mount footprint, hole spacing and mounting-hole diameter increase with load capacity, so the isolator model should be selected from the actual machine weight distribution rather than total weight alone.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTypical Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrecision metrology and inspection systems\u003c\/li\u003e\n\u003cli\u003eSemiconductor stages and wafer inspection equipment\u003c\/li\u003e\n\u003cli\u003eLarge precision positioning systems\u003c\/li\u003e\n\u003cli\u003eEquipment with rapidly moving stages where settling time matters\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv style=\"border-left:4px solid #005f91;background:#eef7fb;padding:16px;margin:20px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help selecting the correct configuration?\u003c\/strong\u003e\u003cp\u003eSend Auckland Scientific your instrument model, footprint, weight and installation conditions. We can help select the appropriate DAEIL configuration and provide a quotation.\u003c\/p\u003e\n\u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eRequest a Quote\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv style=\"border:1px solid #d6e5ed;background:#f7fbfd;padding:16px;margin:20px 0;border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#005f91;\"\u003eOfficial DAEIL Literature\u003c\/strong\u003e\n  \u003cp\u003eOfficial DAEIL SYSTEMS product literature covering the passive vibration-isolation range, specifications and applications.\u003c\/p\u003e\n  \u003ca href=\"https:\/\/www.daeilsys.com\/support\/resources\/catalogs\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eView DAEIL Product Catalog\u003c\/a\u003e\n  \u003c\/div\u003e\u003cdiv data-auckland-quote-block=\"true\" style=\"border:2px solid #005f91;background:#eef7fb;padding:18px;margin:24px 0;border-radius:6px;\"\u003e\n  \u003ch3 style=\"color:#005f91;margin-top:0;\"\u003eRequest a Quote\u003c\/h3\u003e\n  \u003cp\u003eThis product is supplied on a quotation basis. Contact Auckland Scientific with your application, required specification and delivery location and we will provide advice and pricing.\u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eSend an Enquiry\u003c\/a\u003e\n    \u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk?subject=Quote%20request%3A%20DAEIL%20DVIM-G%20Advanced%20Pneumatic%20Vibration%20Isolator\u0026amp;body=Hello%20Michael%2C%0A%0AI%20would%20like%20a%20quotation%20for%20DAEIL%20DVIM-G%20Advanced%20Pneumatic%20Vibration%20Isolator.%0A%0APlease%20contact%20me%20to%20discuss%20my%20requirements.%0A%0AName%3A%0ACompany%3A%0ATelephone%3A%0ADelivery%20location%3A%0AApplication%20%2F%20specification%20required%3A%0A\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eEmail Michael\u003c\/a\u003e\n    \u003ca href=\"tel:+447853690001\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 0 8px 0;\"\u003eCall 07853 690001\u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp style=\"margin-bottom:0;\"\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e michael.hallewell@auckland-scientific.co.uk\u003cbr\u003e\u003cstrong\u003eTelephone:\u003c\/strong\u003e 07853 690001\u003c\/p\u003e\n\u003c\/div\u003e","brand":"DAEIL SYSTEMS","offers":[{"title":"DVIM-G-500 — 500 kg maximum payload","offer_id":59793586127173,"sku":"DVIM-G-500","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-G-1000 — 1000 kg maximum payload","offer_id":59793586159941,"sku":"DVIM-G-1000","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-G-1500 — 1500 kg maximum payload","offer_id":59793586192709,"sku":"DVIM-G-1500","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-G-2000 — 2000 kg maximum payload","offer_id":59793586225477,"sku":"DVIM-G-2000","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-G-3000 — 3000 kg maximum payload","offer_id":59793586258245,"sku":"DVIM-G-3000","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-G-4500 — 4500 kg maximum payload","offer_id":59793586291013,"sku":"DVIM-G-4500","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-G-6000 — 6000 kg maximum payload","offer_id":59793586323781,"sku":"DVIM-G-6000","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/dvim-g.webp?v=1792246004"},{"product_id":"daeil-dvip-b-pneumatic-isolation-base","title":"DAEIL DVIP-B Pneumatic Isolation Base","description":"\u003ch2 style=\"color:#005f91;\"\u003eDAEIL DVIP-B Pneumatic Isolation Base\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDVIP-B\u003c\/strong\u003e is a low-profile, custom-engineered pneumatic isolation base for heavy precision instruments including SEM, TEM and metrology systems. Rather than forcing a large instrument onto a standard table, the platform is designed around the exact footprint, load distribution and support points of the equipment.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eDesigned Around the Instrument\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom equipment interface:\u003c\/strong\u003e chassis geometry is matched to instrument dimensions, mass distribution, caster points and mounting positions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-profile architecture:\u003c\/strong\u003e keeps tall or heavy tools close to their intended operating height.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh centre-of-gravity stability:\u003c\/strong\u003e useful for electron-microscope columns and other tall precision systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless-steel top surface:\u003c\/strong\u003e durable precision equipment interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision levelling option:\u003c\/strong\u003e ±0.05 mm repeatability where required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003ePerformance\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003ePneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eResonant frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e1.2–3.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003ePublished isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e80–99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003ePayload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e400–6,000 kg, custom-engineered to the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;\"\u003e\u003cstrong\u003eLevelling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e±1.0 mm standard; ±0.05 mm precision option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTypical Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eScanning electron microscopes (SEM)\u003c\/li\u003e\n\u003cli\u003eTransmission electron microscopes (TEM)\u003c\/li\u003e\n\u003cli\u003eHeavy optical and surface-metrology equipment\u003c\/li\u003e\n\u003cli\u003ePrecision inspection tools with a demanding floor-vibration specification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuotation information:\u003c\/strong\u003e please provide instrument make\/model, total weight, footprint, caster or support-point locations and, where available, the manufacturer's floor-vibration requirement.\u003c\/p\u003e\u003cdiv style=\"border-left:4px solid #005f91;background:#eef7fb;padding:16px;margin:20px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help selecting the correct configuration?\u003c\/strong\u003e\u003cp\u003eSend Auckland Scientific your instrument model, footprint, weight and installation conditions. We can help select the appropriate DAEIL configuration and provide a quotation.\u003c\/p\u003e\n\u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eRequest a Quote\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv style=\"border:1px solid #d6e5ed;background:#f7fbfd;padding:16px;margin:20px 0;border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#005f91;\"\u003eOfficial DAEIL Literature\u003c\/strong\u003e\n  \u003cp\u003eOfficial DAEIL SYSTEMS product literature covering the passive vibration-isolation range, specifications and applications.\u003c\/p\u003e\n  \u003ca href=\"https:\/\/www.daeilsys.com\/support\/resources\/catalogs\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eView DAEIL Product Catalog\u003c\/a\u003e\n  \u003c\/div\u003e\u003cdiv data-auckland-quote-block=\"true\" style=\"border:2px solid #005f91;background:#eef7fb;padding:18px;margin:24px 0;border-radius:6px;\"\u003e\n  \u003ch3 style=\"color:#005f91;margin-top:0;\"\u003eRequest a Quote\u003c\/h3\u003e\n  \u003cp\u003eThis product is supplied on a quotation basis. Contact Auckland Scientific with your application, required specification and delivery location and we will provide advice and pricing.\u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eSend an Enquiry\u003c\/a\u003e\n    \u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk?subject=Quote%20request%3A%20DAEIL%20DVIP-B%20Pneumatic%20Isolation%20Base\u0026amp;body=Hello%20Michael%2C%0A%0AI%20would%20like%20a%20quotation%20for%20DAEIL%20DVIP-B%20Pneumatic%20Isolation%20Base.%0A%0APlease%20contact%20me%20to%20discuss%20my%20requirements.%0A%0AName%3A%0ACompany%3A%0ATelephone%3A%0ADelivery%20location%3A%0AApplication%20%2F%20specification%20required%3A%0A\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eEmail Michael\u003c\/a\u003e\n    \u003ca href=\"tel:+447853690001\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 0 8px 0;\"\u003eCall 07853 690001\u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp style=\"margin-bottom:0;\"\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e michael.hallewell@auckland-scientific.co.uk\u003cbr\u003e\u003cstrong\u003eTelephone:\u003c\/strong\u003e 07853 690001\u003c\/p\u003e\n\u003c\/div\u003e","brand":"DAEIL SYSTEMS","offers":[{"title":"Custom instrument platform","offer_id":59793587470661,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/dvip-b.webp?v=1792246027"},{"product_id":"daeil-dvim-m-standard-pneumatic-vibration-isolator","title":"DAEIL DVIM-M Standard Pneumatic Vibration Isolator","description":"\u003ch2 style=\"color:#005f91;\"\u003eDAEIL DVIM-M Standard Pneumatic Vibration Isolator\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDVIM-M\u003c\/strong\u003e is a versatile pneumatic isolation mount for heavy machinery, metrology systems and precision equipment. It combines pneumatic isolation with damping options intended to reduce transmitted floor vibration while controlling motion generated by the supported machine itself.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBroad model range for equipment from relatively light precision assemblies through multi-tonne machinery.\u003c\/li\u003e\n\u003cli\u003eOptional internal oil-damper versions for improved settling after stage or machine movement.\u003c\/li\u003e\n\u003cli\u003eAutomatic levelling maintains platform height as load distribution changes.\u003c\/li\u003e\n\u003cli\u003ePrecision levelling option is available where tighter height repeatability is required.\u003c\/li\u003e\n\u003cli\u003eCustom structures can be engineered around DVIM-M mounts for complete isolation bases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003ePerformance\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003ePneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eNatural frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e2.5–4.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation at 10 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e80–90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;\"\u003e\u003cstrong\u003eModel capacity range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e100–4,500 kg maximum payload per isolator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eDAEIL publishes standard and oil-damped configurations. For larger models, the manufacturer's guidance recommends selecting the installation from the actual load distribution and leaving an engineering margin rather than operating continuously at the maximum published capacity.\u003c\/p\u003e\u003cdiv style=\"border-left:4px solid #005f91;background:#eef7fb;padding:16px;margin:20px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help selecting the correct configuration?\u003c\/strong\u003e\u003cp\u003eSend Auckland Scientific your instrument model, footprint, weight and installation conditions. We can help select the appropriate DAEIL configuration and provide a quotation.\u003c\/p\u003e\n\u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eRequest a Quote\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv style=\"border:1px solid #d6e5ed;background:#f7fbfd;padding:16px;margin:20px 0;border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#005f91;\"\u003eOfficial DAEIL Literature\u003c\/strong\u003e\n  \u003cp\u003eOfficial DAEIL SYSTEMS product literature covering the passive vibration-isolation range, specifications and applications.\u003c\/p\u003e\n  \u003ca href=\"https:\/\/www.daeilsys.com\/support\/resources\/catalogs\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eView DAEIL Product Catalog\u003c\/a\u003e\n  \u003c\/div\u003e\u003cdiv data-auckland-quote-block=\"true\" style=\"border:2px solid #005f91;background:#eef7fb;padding:18px;margin:24px 0;border-radius:6px;\"\u003e\n  \u003ch3 style=\"color:#005f91;margin-top:0;\"\u003eRequest a Quote\u003c\/h3\u003e\n  \u003cp\u003eThis product is supplied on a quotation basis. Contact Auckland Scientific with your application, required specification and delivery location and we will provide advice and pricing.\u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eSend an Enquiry\u003c\/a\u003e\n    \u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk?subject=Quote%20request%3A%20DAEIL%20DVIM-M%20Standard%20Pneumatic%20Vibration%20Isolator\u0026amp;body=Hello%20Michael%2C%0A%0AI%20would%20like%20a%20quotation%20for%20DAEIL%20DVIM-M%20Standard%20Pneumatic%20Vibration%20Isolator.%0A%0APlease%20contact%20me%20to%20discuss%20my%20requirements.%0A%0AName%3A%0ACompany%3A%0ATelephone%3A%0ADelivery%20location%3A%0AApplication%20%2F%20specification%20required%3A%0A\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eEmail Michael\u003c\/a\u003e\n    \u003ca href=\"tel:+447853690001\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 0 8px 0;\"\u003eCall 07853 690001\u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp style=\"margin-bottom:0;\"\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e michael.hallewell@auckland-scientific.co.uk\u003cbr\u003e\u003cstrong\u003eTelephone:\u003c\/strong\u003e 07853 690001\u003c\/p\u003e\n\u003c\/div\u003e","brand":"DAEIL SYSTEMS","offers":[{"title":"DVIM-M-100 — 100 kg maximum payload","offer_id":59793589535045,"sku":"DVIM-M-100","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-M-300 — 300 kg maximum payload","offer_id":59793589567813,"sku":"DVIM-M-300","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-M-600 — 600 kg maximum payload","offer_id":59793589600581,"sku":"DVIM-M-600","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-M-900 — 900 kg maximum payload","offer_id":59793589633349,"sku":"DVIM-M-900","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-M-1200 — 1200 kg maximum payload","offer_id":59793589666117,"sku":"DVIM-M-1200","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-M-1500 — 1500 kg maximum payload","offer_id":59793589698885,"sku":"DVIM-M-1500","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-M-2000 — 2000 kg maximum payload","offer_id":59793589731653,"sku":"DVIM-M-2000","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-M-2500 — 2500 kg maximum payload","offer_id":59793589764421,"sku":"DVIM-M-2500","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-M-3000 — 3000 kg maximum payload","offer_id":59793589797189,"sku":"DVIM-M-3000","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-M-4500 — 4500 kg maximum payload","offer_id":59793589829957,"sku":"DVIM-M-4500","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/dvim-m.webp?v=1792246016"},{"product_id":"daeil-dvim-f-basic-pneumatic-vibration-isolator","title":"DAEIL DVIM-F Basic Pneumatic Vibration Isolator","description":"\u003ch2 style=\"color:#005f91;\"\u003eDAEIL DVIM-F Basic Pneumatic Vibration Isolator\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDVIM-F\u003c\/strong\u003e is DAEIL's economical pneumatic isolator for industrial and laboratory equipment that benefits from stable pneumatic support and automatic levelling but does not require the very low natural frequency of the higher-performance DVIM models.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHeavy-duty reinforced air-spring construction designed for durability and long service life.\u003c\/li\u003e\n\u003cli\u003eProvides passive isolation in both vertical and horizontal directions.\u003c\/li\u003e\n\u003cli\u003eOptional internal oil damper can improve settling behaviour where the supported equipment contains moving stages.\u003c\/li\u003e\n\u003cli\u003eOptional precision levelling system offers ±0.05 mm repeatability for more demanding installations.\u003c\/li\u003e\n\u003cli\u003eSuitable where cost-effective pneumatic isolation is required for less vibration-sensitive equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003ePerformance\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003ePneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eNatural frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e5.0–6.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation at 10 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e20–50%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eLevelling repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e±1.0 mm standard; optional ±0.05 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;\"\u003e\u003cstrong\u003eAvailable model capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e500–3,000 kg maximum payload per isolator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eModel Sizes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDVIM-F-500 — 220 × 220 × 152 mm\u003c\/li\u003e\n\u003cli\u003eDVIM-F-1000 — 240 × 240 × 152 mm\u003c\/li\u003e\n\u003cli\u003eDVIM-F-1500 — 300 × 300 × 152 mm\u003c\/li\u003e\n\u003cli\u003eDVIM-F-2000 — 320 × 320 × 152 mm\u003c\/li\u003e\n\u003cli\u003eDVIM-F-2500 — 360 × 360 × 172 mm\u003c\/li\u003e\n\u003cli\u003eDVIM-F-3000 — 380 × 380 × 172 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePayload figures are per isolator. The correct number of isolators, load distribution and mounting geometry must be selected for the complete machine or frame.\u003c\/p\u003e\u003cdiv style=\"border-left:4px solid #005f91;background:#eef7fb;padding:16px;margin:20px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help selecting the correct configuration?\u003c\/strong\u003e\u003cp\u003eSend Auckland Scientific your instrument model, footprint, weight and installation conditions. We can help select the appropriate DAEIL configuration and provide a quotation.\u003c\/p\u003e\n\u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eRequest a Quote\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv style=\"border:1px solid #d6e5ed;background:#f7fbfd;padding:16px;margin:20px 0;border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#005f91;\"\u003eOfficial DAEIL Literature\u003c\/strong\u003e\n  \u003cp\u003eOfficial DAEIL SYSTEMS product literature covering the passive vibration-isolation range, specifications and applications.\u003c\/p\u003e\n  \u003ca href=\"https:\/\/www.daeilsys.com\/support\/resources\/catalogs\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eView DAEIL Product Catalog\u003c\/a\u003e\n  \u003c\/div\u003e\u003cdiv data-auckland-quote-block=\"true\" style=\"border:2px solid #005f91;background:#eef7fb;padding:18px;margin:24px 0;border-radius:6px;\"\u003e\n  \u003ch3 style=\"color:#005f91;margin-top:0;\"\u003eRequest a Quote\u003c\/h3\u003e\n  \u003cp\u003eThis product is supplied on a quotation basis. Contact Auckland Scientific with your application, required specification and delivery location and we will provide advice and pricing.\u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eSend an Enquiry\u003c\/a\u003e\n    \u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk?subject=Quote%20request%3A%20DAEIL%20DVIM-F%20Basic%20Pneumatic%20Vibration%20Isolator\u0026amp;body=Hello%20Michael%2C%0A%0AI%20would%20like%20a%20quotation%20for%20DAEIL%20DVIM-F%20Basic%20Pneumatic%20Vibration%20Isolator.%0A%0APlease%20contact%20me%20to%20discuss%20my%20requirements.%0A%0AName%3A%0ACompany%3A%0ATelephone%3A%0ADelivery%20location%3A%0AApplication%20%2F%20specification%20required%3A%0A\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eEmail Michael\u003c\/a\u003e\n    \u003ca href=\"tel:+447853690001\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 0 8px 0;\"\u003eCall 07853 690001\u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp style=\"margin-bottom:0;\"\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e michael.hallewell@auckland-scientific.co.uk\u003cbr\u003e\u003cstrong\u003eTelephone:\u003c\/strong\u003e 07853 690001\u003c\/p\u003e\n\u003c\/div\u003e","brand":"DAEIL SYSTEMS","offers":[{"title":"DVIM-F-500 — 500 kg maximum payload","offer_id":59793590911301,"sku":"DVIM-F-500","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-F-1000 — 1000 kg maximum payload","offer_id":59793590944069,"sku":"DVIM-F-1000","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-F-1500 — 1500 kg maximum payload","offer_id":59793590976837,"sku":"DVIM-F-1500","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-F-2000 — 2000 kg maximum payload","offer_id":59793591009605,"sku":"DVIM-F-2000","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-F-2500 — 2500 kg maximum payload","offer_id":59793591042373,"sku":"DVIM-F-2500","price":0.0,"currency_code":"GBP","in_stock":true},{"title":"DVIM-F-3000 — 3000 kg maximum payload","offer_id":59793591075141,"sku":"DVIM-F-3000","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/dvim-f.webp?v=1792246090"}],"url":"https:\/\/auckland-scientific.co.uk\/collections\/vibration-isolation-systems.oembed","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}