{"product_id":"auc-209-i-trinocular-inverted-biological-led-microscope","title":"AUC-209-I Trinocular Inverted Biological LED Microscope","description":"\u003cdiv style=\"font-family: Arial,Helvetica,sans-serif; color: #263746; line-height: 1.65; max-width: 1100px; margin: 0 auto;\"\u003e\n\u003cdiv style=\"background: #073b63; color: #ffffff; padding: 28px 30px; border-radius: 8px; margin-bottom: 24px;\"\u003e\n\u003cp style=\"margin: 0 0 7px; font-size: 14px; letter-spacing: 1.4px; text-transform: uppercase; font-weight: bold; color: #cfe9f8;\"\u003eInverted biological microscope\u003c\/p\u003e\n\u003ch2 style=\"margin: 0 0 12px; font-size: 30px; line-height: 1.2; color: #ffffff; font-weight: 800;\"\u003eAUC-209-I Trinocular Inverted Biological Microscope\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 18px; color: #ffffff;\"\u003eBrightfield and phase-contrast observation for living cells, microorganisms and tissue culture\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #edf7fc; border-left: 6px solid #1598d1; padding: 18px 21px; margin: 0 0 25px;\"\u003e\n\u003cp style=\"margin: 0; font-size: 16px; color: #073b63;\"\u003e\u003cstrong\u003eComplete trinocular configuration with built-in 0.65× C-mount adapter and three-year Auckland Scientific microscope warranty*\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe \u003cstrong\u003eAUC-209-I\u003c\/strong\u003e is an infinity-corrected inverted biological microscope designed for observing cultured living cells, microorganisms, bacteria and tissue samples in culture vessels. Its inverted arrangement provides convenient access to specimens held in flasks, dishes and suitable culture containers, making it well suited to medical, university, research and industrial laboratories.\u003c\/p\u003e\n\u003cp\u003eThe confirmed standard configuration provides \u003cstrong\u003ebrightfield observation at 100× and 400× total magnification\u003c\/strong\u003e, together with \u003cstrong\u003ephase-contrast observation at 200×\u003c\/strong\u003e. A trinocular viewing head and built-in 0.65× C-mount adapter allow a compatible digital camera to be connected for live display, image capture, video recording and measurement when used with appropriate camera software.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/AUC-209-I-Customer-Brochure.pdf?v=1786206418\"\u003eClick to view the PDF Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eKey features\u003c\/h2\u003e\n\u003cul style=\"padding-left: 23px; margin: 0 0 26px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eInfinity-corrected optical system\u003c\/strong\u003e for clear, flat-field biological observation\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTrinocular viewing head\u003c\/strong\u003e with 70:30 eyepiece-to-camera light distribution\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003e10× and 40× infinity LWD plan objectives\u003c\/strong\u003e for brightfield observation\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003e20× infinity LWD plan phase-contrast objective\u003c\/strong\u003e supplied as standard\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003e20×\/40× phase annular plate\u003c\/strong\u003e included\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eThree-layer mechanical stage\u003c\/strong\u003e with 75 × 40mm movement\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLong-working-distance condenser\u003c\/strong\u003e with 48mm working distance\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003e5W LED transmitted illumination\u003c\/strong\u003e for consistent, energy-efficient observation\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBuilt-in 0.65× C-mount adapter included\u003c\/strong\u003e for connecting a compatible microscope camera\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-year Auckland Scientific microscope warranty\u003c\/strong\u003e, subject to annual servicing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eBrightfield and phase-contrast observation\u003c\/h2\u003e\n\u003cp\u003ePhase contrast improves the visibility of transparent, low-contrast biological specimens without requiring routine staining. The supplied 20× phase-contrast objective and matching annular plate are particularly valuable for observing living cells and microorganisms within culture media.\u003c\/p\u003e\n\u003cp\u003eThe microscope is also supplied with 10× and 40× plan brightfield objectives. Optional 10× and 40× phase-contrast objectives are available for laboratories requiring additional phase-contrast magnifications.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0 28px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 720px; font-size: 15px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #073b63; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left;\"\u003eSupplied objective\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left;\"\u003eObservation method\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left;\"\u003eNA\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left;\"\u003eWorking distance\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left;\"\u003eTotal magnification*\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e10× infinity LWD plan\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eBrightfield\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e0.25\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e10.3mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e100×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e20× infinity LWD plan phase\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003ePhase contrast\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e0.45\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e5.8mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e200×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e40× infinity LWD plan\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eBrightfield\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e0.65\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e5.1mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e400×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #647580; margin-top: -16px;\"\u003e*Total magnification calculated using the supplied 10× eyepieces.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eTrinocular imaging capability\u003c\/h2\u003e\n\u003cp\u003eThe 45° inclined trinocular viewing head provides an interpupillary adjustment range of 48–75mm and a fixed light distribution of \u003cstrong\u003e70% to the eyepieces and 30% to the trinocular camera port\u003c\/strong\u003e. This allows simultaneous visual observation and camera imaging.\u003c\/p\u003e\n\u003cdiv style=\"background: #f3f7f9; padding: 20px 22px; border-radius: 7px; margin: 22px 0 28px;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; color: #073b63; font-size: 19px; font-weight: 800;\"\u003eBuilt-in 0.65× C-mount adapter included\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eUnlike systems that require a separate camera adapter, the AUC-209-I includes a built-in 0.65× C-mount adapter as part of the standard configuration. A compatible C-mount microscope camera can be added for image capture, video recording, documentation and measurement. Camera and imaging software are not included unless specified separately in your quotation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eMechanical stage and specimen support\u003c\/h2\u003e\n\u003cp\u003eThe three-layer mechanical stage measures 180 × 155mm and provides a 75 × 40mm movement range with 0.1mm graduations. The supplied glass holder has an outer diameter of 110mm and an inner diameter of 30mm. Additional stage and holder options are available for different culture vessels and specimen formats.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eComplete specification\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0 28px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 720px; font-size: 14px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #073b63; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left; width: 27%;\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left;\"\u003eAUC-209-I specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eOptical system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eInfinity-corrected optical system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eViewing head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e45° inclined trinocular head; interpupillary distance 48–75mm; eyepiece:camera split 70:30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eEyepieces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eHigh-eyepoint widefield SW10×\/20mm; Ø23.2mm eyepiece tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eObjectives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e10× and 40× infinity LWD plan; 20× infinity LWD plan phase contrast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eNosepiece\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eQuadruple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003ePhase annulus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eCombined 20×\/40× phase annular plate included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eStage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eThree-layer mechanical stage, 180 × 155mm; travel 75 × 40mm; 0.1mm scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eSupplied holder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eGlass holder, Ø110mm outer diameter and Ø30mm inner diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eFocusing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eCoaxial coarse and fine focusing; 10mm coarse stroke; 0.2mm fine stroke per rotation; 2μm divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eCondenser\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eLong working distance, NA 0.32; working distance 48mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eIllumination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e5W LED transmitted illumination; 100–240V input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eFilter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eGreen filter, Ø21mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eCamera connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eBuilt-in 0.65× C-mount adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eDimensions and weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003ePacking 515 × 480 × 315mm; net weight 7kg; gross weight 9kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eStandard package\u003c\/h2\u003e\n\u003cul style=\"padding-left: 23px; margin-bottom: 28px;\"\u003e\n\u003cli\u003eAUC-209-I trinocular inverted microscope body\u003c\/li\u003e\n\u003cli\u003ePair of SW10×\/20mm widefield eyepieces\u003c\/li\u003e\n\u003cli\u003e10× infinity LWD plan brightfield objective\u003c\/li\u003e\n\u003cli\u003e20× infinity LWD plan phase-contrast objective\u003c\/li\u003e\n\u003cli\u003e40× infinity LWD plan brightfield objective\u003c\/li\u003e\n\u003cli\u003e20×\/40× phase annular plate\u003c\/li\u003e\n\u003cli\u003eThree-layer mechanical stage\u003c\/li\u003e\n\u003cli\u003eØ110\/30mm glass holder\u003c\/li\u003e\n\u003cli\u003eLong-working-distance condenser, NA 0.32\u003c\/li\u003e\n\u003cli\u003e5W LED illumination system\u003c\/li\u003e\n\u003cli\u003eGreen filter\u003c\/li\u003e\n\u003cli\u003eBuilt-in 0.65× C-mount adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eTypical applications\u003c\/h2\u003e\n\u003cul style=\"padding-left: 23px; margin-bottom: 28px;\"\u003e\n\u003cli\u003eLiving-cell and tissue-culture observation\u003c\/li\u003e\n\u003cli\u003eMonitoring cell growth and division\u003c\/li\u003e\n\u003cli\u003eMicrobiology and bacterial observation\u003c\/li\u003e\n\u003cli\u003eCytology, parasitology and oncology research\u003c\/li\u003e\n\u003cli\u003eImmunology and genetic-engineering laboratories\u003c\/li\u003e\n\u003cli\u003eIndustrial microbiology and botanical research\u003c\/li\u003e\n\u003cli\u003eUniversity teaching and laboratory research\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background: #073b63; color: #ffffff; padding: 24px 25px; border-radius: 7px; margin: 30px 0 22px;\"\u003e\n\u003ch2 style=\"margin: 0 0 10px; font-size: 23px; color: #ffffff; font-weight: 800;\"\u003eThree-year Auckland Scientific warranty\u003c\/h2\u003e\n\u003cp style=\"margin: 0; color: #ffffff;\"\u003eThe AUC-209-I is supplied with a three-year Auckland Scientific microscope warranty, subject to the microscope receiving an annual service. Full warranty terms are available on request.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 2px solid #1598d1; padding: 22px 24px; border-radius: 7px; margin-bottom: 24px;\"\u003e\n\u003ch2 style=\"margin: 0 0 10px; font-size: 23px; color: #073b63; font-weight: 800;\"\u003eRequest a quotation\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003ePlease contact Auckland Scientific for current pricing, availability, camera options and application advice. Delivery, installation and training are not included and will be quoted separately where required.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eTelephone:\u003c\/strong\u003e \u003ca href=\"tel:07853690001\" style=\"color: #087cae; font-weight: bold;\"\u003e07853 690001\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e \u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk\" style=\"color: #087cae; font-weight: bold;\"\u003emichael.hallewell@auckland-scientific.co.uk\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003eWebsite:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.auckland-scientific.co.uk\" style=\"color: #087cae; font-weight: bold;\"\u003ewww.auckland-scientific.co.uk\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #647580; border-top: 1px solid #cad6dd; padding-top: 15px;\"\u003e*Three-year warranty is conditional upon annual servicing. Delivery, installation and training are quoted separately. A microscope camera and imaging software are not included unless stated in the formal quotation. Specifications relate to the confirmed AUC-209-I standard package and may be subject to technical improvement.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":58806179332421,"sku":"AUC-209-I","price":1760.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/209.jpg?v=1786205660","url":"https:\/\/auckland-scientific.co.uk\/products\/auc-209-i-trinocular-inverted-biological-led-microscope","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}