{"product_id":"auc-290-i-trinocular-inverted-biological-halogen-microscope-with-brightfield-phase-contrast","title":"AUC-290-I Trinocular Inverted Biological Halogen Microscope with Brightfield \u0026 Phase Contrast","description":"\u003cdiv style=\"font-family: Arial,Helvetica,sans-serif; color: #263746; line-height: 1.65; max-width: 1100px; margin: 0 auto;\"\u003e\n\u003cdiv style=\"background: #073b63; color: #ffffff; padding: 28px 30px; border-radius: 8px; margin-bottom: 24px;\"\u003e\n\u003cp style=\"margin: 0 0 7px; font-size: 14px; letter-spacing: 1.4px; text-transform: uppercase; font-weight: bold; color: #cfe9f8;\"\u003eAdvanced inverted biological microscopy\u003c\/p\u003e\n\u003ch2 style=\"margin: 0 0 12px; font-size: 30px; line-height: 1.2; color: #ffffff; font-weight: 800;\"\u003eAUC-290-I Trinocular Inverted Biological Microscope\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 18px; color: #ffffff;\"\u003eInfinity-corrected brightfield and phase-contrast observation for living cells and tissue culture\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #edf7fc; border-left: 6px solid #1598d1; padding: 18px 21px; margin: 0 0 25px;\"\u003e\n\u003cp style=\"margin: 0; font-size: 16px; color: #073b63;\"\u003e\u003cstrong\u003eFour-objective brightfield and phase-contrast configuration with an included 0.45× C-mount adapter and three-year Auckland Scientific microscope warranty*\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe \u003cstrong\u003eAUC-290-I\u003c\/strong\u003e is a high-level trinocular inverted biological microscope designed for observing cultured living cells, microorganisms, bacteria and tissue samples. Its infinity-corrected optical system, extra-long-working-distance condenser and spacious stage provide the performance and working clearance required for routine culture-vessel observation in medical, university, research and industrial laboratories.\u003c\/p\u003e\n\u003cp\u003eThe confirmed standard configuration provides brightfield observation at \u003cstrong\u003e40× and 400×\u003c\/strong\u003e total magnification, together with phase-contrast observation at \u003cstrong\u003e100× and 200×\u003c\/strong\u003e. Its trinocular camera port and included \u003cstrong\u003e0.45× C-mount adapter\u003c\/strong\u003e allow a compatible microscope camera to be added for image capture, video recording, documentation and measurement.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/AUC-290-I-Biological_Inverted_Brochure.pdf?v=1786208014\"\u003eClick to view PDF\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eKey features\u003c\/h2\u003e\n\u003cul style=\"padding-left: 23px; margin: 0 0 26px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eInfinity-corrected optical system\u003c\/strong\u003e for clear, flat-field biological observation\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003e30° inclined trinocular head\u003c\/strong\u003e with 48–75mm interpupillary adjustment\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eExtra-wide-field EW10×\/22mm eyepieces\u003c\/strong\u003e for a generous field of view\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003e4× and 40× LWD plan objectives\u003c\/strong\u003e for brightfield observation\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePH10× and PH20× plan phase-contrast objectives\u003c\/strong\u003e supplied as standard\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eFixed 10×–20× phase annulus plate\u003c\/strong\u003e included\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eQuintuple nosepiece\u003c\/strong\u003e with capacity for an additional optional objective\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eExtra-long-working-distance condenser\u003c\/strong\u003e with 72mm working distance\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLarge 160 × 250mm plain stage\u003c\/strong\u003e with glass insert and auxiliary stages\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003e6V\/30W halogen illumination\u003c\/strong\u003e with blue, green and frosted filters\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003e0.45× C-mount adapter included\u003c\/strong\u003e for connecting a compatible digital camera\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-year Auckland Scientific microscope warranty\u003c\/strong\u003e, subject to annual servicing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eBrightfield and phase-contrast observation\u003c\/h2\u003e\n\u003cp\u003ePhase contrast increases the visibility of transparent, low-contrast biological structures without requiring routine staining. The included PH10× and PH20× objectives and matching fixed phase annulus plate provide convenient observation of living cells and microorganisms at 100× and 200× total magnification.\u003c\/p\u003e\n\u003cp\u003eThe supplied 4× and 40× long-working-distance plan objectives provide brightfield observation at 40× and 400×. Optional 10× and 20× brightfield objectives and a PH40× phase-contrast objective are available for laboratories requiring additional observation configurations.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0 28px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 760px; font-size: 15px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #073b63; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left;\"\u003eSupplied objective\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left;\"\u003eObservation method\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left;\"\u003eNA\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left;\"\u003eWorking distance\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left;\"\u003eTotal magnification*\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e4× LWD infinity plan\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eBrightfield\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e0.10\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e17.3mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e40×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003ePH10× infinity plan phase\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003ePhase contrast\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e0.25\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e10mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e100×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003ePH20× infinity plan phase\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003ePhase contrast\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e0.40\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e5.1mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e200×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e40× LWD infinity plan\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eBrightfield\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e0.60\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e2.1mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e400×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #647580; margin-top: -16px;\"\u003e*Total magnification calculated using the supplied 10× eyepieces.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eExtra-long-working-distance condenser\u003c\/h2\u003e\n\u003cp\u003eThe ELWD condenser has a numerical aperture of 0.30 and a working distance of 72mm, providing generous clearance for suitable culture vessels. Removing the condenser increases the available working distance to approximately 150mm when required for larger vessels.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eStage and specimen support\u003c\/h2\u003e\n\u003cp\u003eThe standard 160 × 250mm plain stage is supplied with a glass insert and a pair of 70 × 180mm auxiliary stages. Optional holders are available for Terasaki plates, 35mm and 90mm Petri dishes and 54mm slide glasses. An attachable mechanical stage with coaxial XY controls and a 120 × 78mm movement range is also available separately.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eDigital imaging capability\u003c\/h2\u003e\n\u003cdiv style=\"background: #f3f7f9; padding: 20px 22px; border-radius: 7px; margin: 18px 0 27px;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; color: #073b63; font-size: 19px; font-weight: 800;\"\u003e0.45× C-mount adapter included\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eThe AUC-290-I is supplied with a 0.45× C-mount adapter for connecting a compatible C-mount microscope camera. A suitable camera can be added for live display, image capture, video recording, documentation and measurement. The camera and imaging software are not included unless specified separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eComplete specification\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0 28px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 720px; font-size: 14px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #073b63; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left; width: 27%;\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #b7c8d3; text-align: left;\"\u003eAUC-290-I specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eOptical system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eInfinity-corrected optical system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eViewing head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e30° inclined trinocular head; interpupillary distance 48–75mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eEyepieces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eHigh-eyepoint extra-wide-field EW10×\/22mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eObjectives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e4× and 40× LWD infinity plan; PH10× and PH20× infinity plan phase contrast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eNosepiece\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eQuintuple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eCondenser\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eELWD NA 0.30; working distance 72mm; approximately 150mm without condenser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003ePhase annulus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eFixed 10×–20× phase annulus plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eStage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003ePlain stage 160 × 250mm with glass insert and pair of 70 × 180mm auxiliary stages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eFocusing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eCoaxial coarse\/fine; 0.002mm divisions; 37.7mm coarse and 0.2mm fine movement per rotation; range +8\/−3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eIllumination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e6V\/30W halogen transmitted illumination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eFilters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eBlue, green and frosted filters, Ø45mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003eCamera connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003eIncluded 0.45× C-mount adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f3f7f9;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #b7c8d3;\"\u003e46.5 × 39.5 × 64cm; gross weight 16kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eStandard package\u003c\/h2\u003e\n\u003cul style=\"padding-left: 23px; margin-bottom: 28px;\"\u003e\n\u003cli\u003eAUC-290-I trinocular inverted microscope\u003c\/li\u003e\n\u003cli\u003ePair of EW10×\/22mm extra-wide-field eyepieces\u003c\/li\u003e\n\u003cli\u003e4× and 40× LWD infinity plan brightfield objectives\u003c\/li\u003e\n\u003cli\u003ePH10× and PH20× infinity plan phase-contrast objectives\u003c\/li\u003e\n\u003cli\u003eFixed 10×–20× phase annulus plate\u003c\/li\u003e\n\u003cli\u003eQuintuple nosepiece\u003c\/li\u003e\n\u003cli\u003eELWD condenser, NA 0.30\u003c\/li\u003e\n\u003cli\u003e160 × 250mm plain stage and glass insert\u003c\/li\u003e\n\u003cli\u003ePair of 70 × 180mm auxiliary stages\u003c\/li\u003e\n\u003cli\u003e6V\/30W halogen transmitted illumination\u003c\/li\u003e\n\u003cli\u003eBlue, green and frosted filters\u003c\/li\u003e\n\u003cli\u003e0.45× C-mount adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eTypical applications\u003c\/h2\u003e\n\u003cul style=\"padding-left: 23px; margin-bottom: 28px;\"\u003e\n\u003cli\u003eLiving-cell and tissue-culture observation\u003c\/li\u003e\n\u003cli\u003eMonitoring cell growth and division\u003c\/li\u003e\n\u003cli\u003eMicrobiology and bacterial observation\u003c\/li\u003e\n\u003cli\u003eCytology, parasitology and oncology research\u003c\/li\u003e\n\u003cli\u003eImmunology and genetic-engineering laboratories\u003c\/li\u003e\n\u003cli\u003eIndustrial microbiology and botanical research\u003c\/li\u003e\n\u003cli\u003eUniversity teaching and laboratory research\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 24px; color: #073b63; font-weight: 800; border-bottom: 3px solid #1598d1; padding-bottom: 8px; margin: 32px 0 18px;\"\u003eOptional accessories\u003c\/h2\u003e\n\u003cul style=\"padding-left: 23px; margin-bottom: 28px;\"\u003e\n\u003cli\u003e10× and 20× LWD infinity plan brightfield objectives\u003c\/li\u003e\n\u003cli\u003ePH40× infinity plan phase-contrast objective\u003c\/li\u003e\n\u003cli\u003eØ30mm centring telescope\u003c\/li\u003e\n\u003cli\u003eAttachable 120 × 78mm mechanical stage\u003c\/li\u003e\n\u003cli\u003eTerasaki, Petri-dish and slide-glass holders\u003c\/li\u003e\n\u003cli\u003e3W LED illumination option\u003c\/li\u003e\n\u003cli\u003eDSLR photo attachment\u003c\/li\u003e\n\u003cli\u003eInverted fluorescence attachment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background: #073b63; color: #ffffff; padding: 24px 25px; border-radius: 7px; margin: 30px 0 22px;\"\u003e\n\u003ch2 style=\"margin: 0 0 10px; font-size: 23px; color: #ffffff; font-weight: 800;\"\u003eThree-year Auckland Scientific warranty\u003c\/h2\u003e\n\u003cp style=\"margin: 0; color: #ffffff;\"\u003eThe AUC-290-I is supplied with a three-year Auckland Scientific microscope warranty, subject to the microscope receiving an annual service. Full warranty terms are available on request.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 2px solid #1598d1; padding: 22px 24px; border-radius: 7px; margin-bottom: 24px;\"\u003e\n\u003ch2 style=\"margin: 0 0 10px; font-size: 23px; color: #073b63; font-weight: 800;\"\u003eNeed advice before ordering?\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003eContact Auckland Scientific for availability, compatible camera options and application advice. The product price is displayed separately on this page. Delivery, installation and training are not included in the product price and will be quoted separately where required.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eTelephone:\u003c\/strong\u003e \u003ca href=\"tel:07853690001\" style=\"color: #087cae; font-weight: bold;\"\u003e07853 690001\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e \u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk\" style=\"color: #087cae; font-weight: bold;\"\u003emichael.hallewell@auckland-scientific.co.uk\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003eWebsite:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.auckland-scientific.co.uk\" style=\"color: #087cae; font-weight: bold;\"\u003ewww.auckland-scientific.co.uk\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #647580; border-top: 1px solid #cad6dd; padding-top: 15px;\"\u003e*Three-year warranty is conditional upon annual servicing. Delivery, installation and training are quoted separately. A microscope camera and imaging software are not included unless stated in the formal order confirmation. Specifications relate to the confirmed AUC-290-I standard package and may be subject to technical improvement.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":58806242378053,"sku":"AUC-290-I","price":2450.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/290.jpg?v=1786206713","url":"https:\/\/auckland-scientific.co.uk\/products\/auc-290-i-trinocular-inverted-biological-halogen-microscope-with-brightfield-phase-contrast","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}