{"product_id":"auc-310-hs-transparent-constant-temperature-heating-stage-for-stereo-microscopes","title":"AUC-310-HS Transparent Constant-Temperature Heating Stage for Stereo Microscopes","description":"\u003cdiv style=\"max-width:1100px; margin:0 auto; color:#17243a; font-family:Arial, Helvetica, sans-serif; line-height:1.65;\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003csection style=\"overflow:hidden; margin-bottom:28px; border:1px solid #dce5ef; border-radius:18px; background:linear-gradient(135deg,#071f3d 0%,#0b4f78 58%,#1186a5 100%); box-shadow:0 12px 30px rgba(7,31,61,0.14);\"\u003e\n    \u003cdiv style=\"padding:46px 42px; color:#ffffff;\"\u003e\n\n      \u003cdiv style=\"display:inline-block; margin-bottom:16px; padding:7px 13px; border:1px solid rgba(255,255,255,0.35); border-radius:30px; background:rgba(255,255,255,0.12); font-size:12px; font-weight:700; letter-spacing:1.2px; text-transform:uppercase;\"\u003e\n        Stereo Microscope Accessory\n      \u003c\/div\u003e\n\n      \u003ch1 style=\"max-width:850px; margin:0 0 14px; color:#ffffff; font-size:38px; line-height:1.15;\"\u003e\n        AUC-310-HS Transparent Constant-Temperature Heating Stage\n      \u003c\/h1\u003e\n\n      \u003cp style=\"max-width:790px; margin:0 0 24px; color:#dcecf5; font-size:19px; line-height:1.55;\"\u003e\n        Precision-controlled specimen heating for stereo microscope observation, supplied as a complete system with digital controller, power supply and connecting cables.\n      \u003c\/p\u003e\n\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; gap:10px;\"\u003e\n        \u003cspan style=\"display:inline-block; padding:9px 14px; border-radius:8px; background:#ffffff; color:#093c60; font-size:14px; font-weight:700;\"\u003e\n          Ambient to 60°C\n        \u003c\/span\u003e\n\n        \u003cspan style=\"display:inline-block; padding:9px 14px; border-radius:8px; background:#ffffff; color:#093c60; font-size:14px; font-weight:700;\"\u003e\n          ±0.1°C Central Accuracy\n        \u003c\/span\u003e\n\n        \u003cspan style=\"display:inline-block; padding:9px 14px; border-radius:8px; background:#ffffff; color:#093c60; font-size:14px; font-weight:700;\"\u003e\n          \u0026gt;95% Light Transmission\n        \u003c\/span\u003e\n\n        \u003cspan style=\"display:inline-block; padding:9px 14px; border-radius:8px; background:#ffffff; color:#093c60; font-size:14px; font-weight:700;\"\u003e\n          Complete Heating System\n        \u003c\/span\u003e\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- INTRODUCTION --\u003e\n  \u003csection style=\"margin-bottom:28px; padding:34px; border:1px solid #dce5ef; border-radius:16px; background:#ffffff; box-shadow:0 8px 24px rgba(7,31,61,0.07);\"\u003e\n\n    \u003cdiv style=\"margin-bottom:8px; color:#1186a5; font-size:13px; font-weight:700; letter-spacing:1.2px; text-transform:uppercase;\"\u003e\n      Controlled Heating During Observation\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0 0 16px; color:#082d50; font-size:28px; line-height:1.25;\"\u003e\n      Clear observation without sacrificing temperature stability\n    \u003c\/h2\u003e\n\n    \u003cp style=\"margin:0 0 15px; font-size:16px;\"\u003e\n      The \u003cstrong\u003eAUC-310-HS\u003c\/strong\u003e is a low-profile transparent heating stage designed for use with a wide range of stereo microscopes. It allows specimens to be observed while maintaining a controlled and stable temperature across the central working area.\n    \u003c\/p\u003e\n\n    \u003cp style=\"margin:0 0 15px; font-size:16px;\"\u003e\n      Its high-hardness optical heating glass provides uniform heating with light transmission of more than 95%, allowing transmitted illumination to pass through the stage with minimal effect on specimen visibility.\n    \u003c\/p\u003e\n\n    \u003cp style=\"margin:0; font-size:16px;\"\u003e\n      The supplied digital controller provides convenient temperature adjustment from ambient temperature up to 60°C. The stage can be set to maintain Petri-dish samples at approximately 37°C, making it particularly useful for observing cells, embryos and other temperature-sensitive biological specimens.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n  \u003c!-- COMPLETE SYSTEM CALLOUT --\u003e\n  \u003csection style=\"margin-bottom:28px; padding:26px 30px; border:1px solid #b9dfe8; border-radius:14px; background:linear-gradient(135deg,#e7f7fa 0%,#f6fcfd 100%);\"\u003e\n\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; align-items:center; gap:20px;\"\u003e\n\n      \u003cdiv style=\"flex:1 1 500px;\"\u003e\n        \u003cdiv style=\"margin-bottom:7px; color:#0b7896; font-size:13px; font-weight:700; letter-spacing:1.1px; text-transform:uppercase;\"\u003e\n          Ready to Use\n        \u003c\/div\u003e\n\n        \u003ch2 style=\"margin:0 0 8px; color:#082d50; font-size:24px;\"\u003e\n          Supplied as a complete temperature-control package\n        \u003c\/h2\u003e\n\n        \u003cp style=\"margin:0; color:#40566a; font-size:15px;\"\u003e\n          The AUC-310-HS includes the transparent heating stage, digital temperature controller, 12V DC power supply and the required connecting cables.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"flex:0 1 260px; padding:16px 20px; border-radius:10px; background:#0b6f91; color:#ffffff; text-align:center;\"\u003e\n        \u003cdiv style=\"font-size:20px; font-weight:800;\"\u003eController Included\u003c\/div\u003e\n        \u003cdiv style=\"color:#d8f0f5; font-size:13px;\"\u003ePower supply and cables included\u003c\/div\u003e\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n  \u003c!-- PERFORMANCE CARDS --\u003e\n  \u003csection style=\"margin-bottom:28px;\"\u003e\n\n    \u003cdiv style=\"margin-bottom:18px;\"\u003e\n      \u003cdiv style=\"margin-bottom:7px; color:#1186a5; font-size:13px; font-weight:700; letter-spacing:1.2px; text-transform:uppercase;\"\u003e\n        Key Performance\n      \u003c\/div\u003e\n\n      \u003ch2 style=\"margin:0; color:#082d50; font-size:28px;\"\u003e\n        Accurate and dependable temperature control\n      \u003c\/h2\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; gap:16px;\"\u003e\n\n      \u003cdiv style=\"flex:1 1 210px; min-width:210px; padding:24px; border:1px solid #dce5ef; border-radius:14px; background:#f7fbfd;\"\u003e\n        \u003cdiv style=\"margin-bottom:8px; color:#0b6f91; font-size:28px; font-weight:800;\"\u003e60°C\u003c\/div\u003e\n        \u003ch3 style=\"margin:0 0 8px; color:#082d50; font-size:18px;\"\u003eMaximum Temperature\u003c\/h3\u003e\n        \u003cp style=\"margin:0; color:#526174; font-size:14px;\"\u003e\n          Adjustable from ambient temperature up to 60°C for a broad range of laboratory applications.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"flex:1 1 210px; min-width:210px; padding:24px; border:1px solid #dce5ef; border-radius:14px; background:#f7fbfd;\"\u003e\n        \u003cdiv style=\"margin-bottom:8px; color:#0b6f91; font-size:28px; font-weight:800;\"\u003e±0.1°C\u003c\/div\u003e\n        \u003ch3 style=\"margin:0 0 8px; color:#082d50; font-size:18px;\"\u003eCentral-Area Accuracy\u003c\/h3\u003e\n        \u003cp style=\"margin:0; color:#526174; font-size:14px;\"\u003e\n          High-precision temperature sensing supports stable control throughout critical observations.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"flex:1 1 210px; min-width:210px; padding:24px; border:1px solid #dce5ef; border-radius:14px; background:#f7fbfd;\"\u003e\n        \u003cdiv style=\"margin-bottom:8px; color:#0b6f91; font-size:28px; font-weight:800;\"\u003e\u0026gt;95%\u003c\/div\u003e\n        \u003ch3 style=\"margin:0 0 8px; color:#082d50; font-size:18px;\"\u003eLight Transmission\u003c\/h3\u003e\n        \u003cp style=\"margin:0; color:#526174; font-size:14px;\"\u003e\n          High optical transmission preserves clear transmitted-light observation through the stage.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"flex:1 1 210px; min-width:210px; padding:24px; border:1px solid #dce5ef; border-radius:14px; background:#f7fbfd;\"\u003e\n        \u003cdiv style=\"margin-bottom:8px; color:#0b6f91; font-size:28px; font-weight:800;\"\u003e8mm\u003c\/div\u003e\n        \u003ch3 style=\"margin:0 0 8px; color:#082d50; font-size:18px;\"\u003eLow-Profile Design\u003c\/h3\u003e\n        \u003cp style=\"margin:0; color:#526174; font-size:14px;\"\u003e\n          The slim construction helps minimise its effect on the available microscope working distance.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- FEATURES --\u003e\n  \u003csection style=\"margin-bottom:28px; padding:34px; border-radius:16px; background:#082d50; color:#ffffff;\"\u003e\n\n    \u003cdiv style=\"margin-bottom:8px; color:#68d1e3; font-size:13px; font-weight:700; letter-spacing:1.2px; text-transform:uppercase;\"\u003e\n      Features\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0 0 24px; color:#ffffff; font-size:28px;\"\u003e\n      Practical temperature control for microscopy\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit,minmax(230px,1fr)); gap:14px;\"\u003e\n\n      \u003cdiv style=\"padding:20px; border:1px solid rgba(255,255,255,0.16); border-radius:12px; background:rgba(255,255,255,0.07);\"\u003e\n        \u003ch3 style=\"margin:0 0 8px; color:#ffffff; font-size:17px;\"\u003eDigital Controller\u003c\/h3\u003e\n        \u003cp style=\"margin:0; color:#d7e5ef; font-size:14px;\"\u003e\n          A clear digital display and intuitive controls make the required temperature quick and easy to set.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"padding:20px; border:1px solid rgba(255,255,255,0.16); border-radius:12px; background:rgba(255,255,255,0.07);\"\u003e\n        \u003ch3 style=\"margin:0 0 8px; color:#ffffff; font-size:17px;\"\u003ePrecise Temperature Control\u003c\/h3\u003e\n        \u003cp style=\"margin:0; color:#d7e5ef; font-size:14px;\"\u003e\n          A high-precision temperature sensor supports stable and reliable control during extended observations.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"padding:20px; border:1px solid rgba(255,255,255,0.16); border-radius:12px; background:rgba(255,255,255,0.07);\"\u003e\n        \u003ch3 style=\"margin:0 0 8px; color:#ffffff; font-size:17px;\"\u003eTransparent Heating Area\u003c\/h3\u003e\n        \u003cp style=\"margin:0; color:#d7e5ef; font-size:14px;\"\u003e\n          The 187 × 140mm transparent area provides ample space for Petri dishes and specimen containers.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"padding:20px; border:1px solid rgba(255,255,255,0.16); border-radius:12px; background:rgba(255,255,255,0.07);\"\u003e\n        \u003ch3 style=\"margin:0 0 8px; color:#ffffff; font-size:17px;\"\u003eDurable Optical Glass\u003c\/h3\u003e\n        \u003cp style=\"margin:0; color:#d7e5ef; font-size:14px;\"\u003e\n          High-hardness optical glass offers excellent durability and resistance to wear during normal laboratory use.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"padding:20px; border:1px solid rgba(255,255,255,0.16); border-radius:12px; background:rgba(255,255,255,0.07);\"\u003e\n        \u003ch3 style=\"margin:0 0 8px; color:#ffffff; font-size:17px;\"\u003eUniform Heating\u003c\/h3\u003e\n        \u003cp style=\"margin:0; color:#d7e5ef; font-size:14px;\"\u003e\n          Designed to provide consistent heating throughout the central observation region.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"padding:20px; border:1px solid rgba(255,255,255,0.16); border-radius:12px; background:rgba(255,255,255,0.07);\"\u003e\n        \u003ch3 style=\"margin:0 0 8px; color:#ffffff; font-size:17px;\"\u003eBroad Compatibility\u003c\/h3\u003e\n        \u003cp style=\"margin:0; color:#d7e5ef; font-size:14px;\"\u003e\n          Suitable for many conventional stereo microscope stands, subject to stage dimensions and clearance.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- APPLICATIONS --\u003e\n  \u003csection style=\"margin-bottom:28px; padding:34px; border:1px solid #dce5ef; border-radius:16px; background:linear-gradient(180deg,#ffffff 0%,#f6fafc 100%);\"\u003e\n\n    \u003cdiv style=\"margin-bottom:8px; color:#1186a5; font-size:13px; font-weight:700; letter-spacing:1.2px; text-transform:uppercase;\"\u003e\n      Applications\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0 0 22px; color:#082d50; font-size:28px;\"\u003e\n      Ideal for temperature-sensitive specimens\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; gap:10px;\"\u003e\n      \u003cspan style=\"padding:10px 15px; border:1px solid #cfe0e9; border-radius:30px; background:#ffffff; color:#24435d; font-size:14px; font-weight:600;\"\u003eLive-cell observation\u003c\/span\u003e\n      \u003cspan style=\"padding:10px 15px; border:1px solid #cfe0e9; border-radius:30px; background:#ffffff; color:#24435d; font-size:14px; font-weight:600;\"\u003eEmbryology\u003c\/span\u003e\n      \u003cspan style=\"padding:10px 15px; border:1px solid #cfe0e9; border-radius:30px; background:#ffffff; color:#24435d; font-size:14px; font-weight:600;\"\u003eDevelopmental studies\u003c\/span\u003e\n      \u003cspan style=\"padding:10px 15px; border:1px solid #cfe0e9; border-radius:30px; background:#ffffff; color:#24435d; font-size:14px; font-weight:600;\"\u003ePetri-dish observation\u003c\/span\u003e\n      \u003cspan style=\"padding:10px 15px; border:1px solid #cfe0e9; border-radius:30px; background:#ffffff; color:#24435d; font-size:14px; font-weight:600;\"\u003eLife-science research\u003c\/span\u003e\n      \u003cspan style=\"padding:10px 15px; border:1px solid #cfe0e9; border-radius:30px; background:#ffffff; color:#24435d; font-size:14px; font-weight:600;\"\u003eLaboratory teaching\u003c\/span\u003e\n      \u003cspan style=\"padding:10px 15px; border:1px solid #cfe0e9; border-radius:30px; background:#ffffff; color:#24435d; font-size:14px; font-weight:600;\"\u003eTemperature-controlled inspection\u003c\/span\u003e\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n  \u003c!-- SPECIFICATIONS --\u003e\n  \u003csection style=\"margin-bottom:28px; padding:34px; border:1px solid #dce5ef; border-radius:16px; background:#ffffff; box-shadow:0 8px 24px rgba(7,31,61,0.06);\"\u003e\n\n    \u003cdiv style=\"margin-bottom:8px; color:#1186a5; font-size:13px; font-weight:700; letter-spacing:1.2px; text-transform:uppercase;\"\u003e\n      Technical Data\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0 0 22px; color:#082d50; font-size:28px;\"\u003e\n      Specifications\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"overflow-x:auto; border:1px solid #dce5ef; border-radius:12px;\"\u003e\n      \u003ctable style=\"width:100%; min-width:560px; border-collapse:collapse; font-size:15px;\"\u003e\n        \u003ctbody\u003e\n\n          \u003ctr\u003e\n            \u003cth style=\"width:42%; padding:14px 16px; border-bottom:1px solid #dce5ef; background:#edf5f8; color:#082d50; text-align:left;\"\u003eModel\u003c\/th\u003e\n            \u003ctd style=\"padding:14px 16px; border-bottom:1px solid #dce5ef;\"\u003e\u003cstrong\u003eAUC-310-HS\u003c\/strong\u003e\u003c\/td\u003e\n          \u003c\/tr\u003e\n\n          \u003ctr\u003e\n            \u003cth style=\"padding:14px 16px; border-bottom:1px solid #dce5ef; background:#f7fafc; color:#082d50; text-align:left;\"\u003eProduct Type\u003c\/th\u003e\n            \u003ctd style=\"padding:14px 16px; border-bottom:1px solid #dce5ef;\"\u003eTransparent constant-temperature heating stage for stereo microscopes\u003c\/td\u003e\n          \u003c\/tr\u003e\n\n          \u003ctr\u003e\n            \u003cth style=\"padding:14px 16px; border-bottom:1px solid #dce5ef; background:#edf5f8; color:#082d50; text-align:left;\"\u003eTemperature Control Range\u003c\/th\u003e\n            \u003ctd style=\"padding:14px 16px; border-bottom:1px solid #dce5ef;\"\u003eAmbient temperature to 60°C\u003c\/td\u003e\n          \u003c\/tr\u003e\n\n          \u003ctr\u003e\n            \u003cth style=\"padding:14px 16px; border-bottom:1px solid #dce5ef; background:#f7fafc; color:#082d50; text-align:left;\"\u003eCentral-Area Temperature Accuracy\u003c\/th\u003e\n            \u003ctd style=\"padding:14px 16px; border-bottom:1px solid #dce5ef;\"\u003e±0.1°C\u003c\/td\u003e\n          \u003c\/tr\u003e\n\n          \u003ctr\u003e\n            \u003cth style=\"padding:14px 16px; border-bottom:1px solid #dce5ef; background:#edf5f8; color:#082d50; text-align:left;\"\u003eOverall Dimensions\u003c\/th\u003e\n            \u003ctd style=\"padding:14px 16px; border-bottom:1px solid #dce5ef;\"\u003e215 × 175 × 8mm\u003c\/td\u003e\n          \u003c\/tr\u003e\n\n          \u003ctr\u003e\n            \u003cth style=\"padding:14px 16px; border-bottom:1px solid #dce5ef; background:#f7fafc; color:#082d50; text-align:left;\"\u003eTransparent Observation Area\u003c\/th\u003e\n            \u003ctd style=\"padding:14px 16px; border-bottom:1px solid #dce5ef;\"\u003e187 × 140mm\u003c\/td\u003e\n          \u003c\/tr\u003e\n\n          \u003ctr\u003e\n            \u003cth style=\"padding:14px 16px; border-bottom:1px solid #dce5ef; background:#edf5f8; color:#082d50; text-align:left;\"\u003eOptical Transmission\u003c\/th\u003e\n            \u003ctd style=\"padding:14px 16px; border-bottom:1px solid #dce5ef;\"\u003eMore than 95%\u003c\/td\u003e\n          \u003c\/tr\u003e\n\n          \u003ctr\u003e\n            \u003cth style=\"padding:14px 16px; border-bottom:1px solid #dce5ef; background:#f7fafc; color:#082d50; text-align:left;\"\u003ePower Supply\u003c\/th\u003e\n            \u003ctd style=\"padding:14px 16px; border-bottom:1px solid #dce5ef;\"\u003e12V DC power supply included\u003c\/td\u003e\n          \u003c\/tr\u003e\n\n          \u003ctr\u003e\n            \u003cth style=\"padding:14px 16px; background:#edf5f8; color:#082d50; text-align:left;\"\u003eRated Power\u003c\/th\u003e\n            \u003ctd style=\"padding:14px 16px;\"\u003e240W\u003c\/td\u003e\n          \u003c\/tr\u003e\n\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n  \u003c!-- SUPPLIED CONFIGURATION --\u003e\n  \u003csection style=\"margin-bottom:28px; overflow:hidden; border:1px solid #dce5ef; border-radius:16px; background:#ffffff;\"\u003e\n\n    \u003cdiv style=\"padding:18px 30px; background:#0b6f91; color:#ffffff;\"\u003e\n      \u003ch2 style=\"margin:0; color:#ffffff; font-size:23px;\"\u003e\n        Supplied Configuration\n      \u003c\/h2\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"padding:28px 30px;\"\u003e\n      \u003cul style=\"margin:0; padding-left:22px;\"\u003e\n        \u003cli style=\"margin-bottom:10px;\"\u003e\u003cstrong\u003eAUC-310-HS transparent constant-temperature heating stage\u003c\/strong\u003e\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:10px;\"\u003e\u003cstrong\u003eDigital temperature controller\u003c\/strong\u003e\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:10px;\"\u003e\u003cstrong\u003e12V DC power supply\u003c\/strong\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003cstrong\u003eRequired connecting cables\u003c\/strong\u003e\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n      \u003cdiv style=\"margin-top:22px; padding:15px 18px; border-radius:9px; background:#eef8fa; color:#24526a; font-size:14px;\"\u003e\n        Supplied as a complete heating and temperature-control package. A stereo microscope is not included.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n  \u003c!-- COMPATIBILITY --\u003e\n  \u003csection style=\"margin-bottom:28px; padding:26px 28px; border-left:5px solid #e2a524; border-radius:10px; background:#fff9eb;\"\u003e\n\n    \u003ch3 style=\"margin:0 0 9px; color:#684b05; font-size:19px;\"\u003e\n      Please confirm microscope compatibility before ordering\n    \u003c\/h3\u003e\n\n    \u003cp style=\"margin:0; color:#5f5131; font-size:15px;\"\u003e\n      Although the AUC-310-HS is suitable for many stereo microscopes, stand dimensions, stage clearance, transmitted illumination and available working distance can vary. Please provide Auckland Scientific with the make and model of your microscope so that suitability can be confirmed before purchase.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n  \u003c!-- SUPPORT --\u003e\n  \u003csection style=\"margin-bottom:22px; padding:34px; border-radius:16px; background:linear-gradient(135deg,#eaf7fa 0%,#f7fbfd 100%); text-align:center;\"\u003e\n\n    \u003ch2 style=\"margin:0 0 10px; color:#082d50; font-size:27px;\"\u003e\n      Need help with compatibility or application requirements?\n    \u003c\/h2\u003e\n\n    \u003cp style=\"max-width:760px; margin:0 auto; color:#45596c; font-size:16px;\"\u003e\n      Auckland Scientific can help confirm compatibility with your existing stereo microscope and advise whether the AUC-310-HS is suitable for your specimen type and required operating temperature.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n  \u003c!-- DISCLAIMER --\u003e\n  \u003cp style=\"margin:0; padding:0 10px; color:#6d7784; font-size:12px; line-height:1.55; text-align:center;\"\u003e\n    Stereo microscope, microscope stand, Petri dishes and specimens shown in application images are not included. Images are for illustration purposes, and the appearance of the supplied product may differ slightly. Specifications may be subject to improvement without prior notice.\n  \u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":58817887830341,"sku":"BHS-310","price":1599.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/310HS.jpg?v=1786351315","url":"https:\/\/auckland-scientific.co.uk\/products\/auc-310-hs-transparent-constant-temperature-heating-stage-for-stereo-microscopes","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}