{"product_id":"camspec-m550-double-beam-scanning-uv-vis-spectrophotometer-1-8nm-bandpass","title":"Camspec M550 Double Beam Scanning UV Vis Spectrophotometer 1.8nm Bandpass","description":"\u003ch1\u003eCamspec M550 Double Beam Scanning UV Vis Spectrophotometer 1.8nm Bandpass\u003c\/h1\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/youtu.be\/JHzJueqwFUQ\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/Camspec_pic.jpg?v=1784482715\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/youtu.be\/JHzJueqwFUQ\"\u003eClick to watch Spectrophometers Overview Video\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDouble beam UV-Vis M550 spectrophotometer designed for research and routine use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLocal or remote control via PC software and USB interface for transfer of results.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eComplies with UKCA and CE requirements for safety and ESD\/EMC emission and susceptibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eParallel sample and reference beams are included as part of the design.\u003c\/p\u003e\n\u003cp\u003eExceptional sensitivity, resolution, stray light, noise and drift specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLarge range of accessories for laboratory automation and specific tests.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCalibrated in the UK by qualified engineers using international standards for wavelength, absorbance, resolution and stray light.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cstrong\u003eOperating Modes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBasic Mode (Abs, %T, Conc)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQuantitative (concentration calibration curves)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eWavelength \u003c\/span\u003e\u003cspan\u003eScanning\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKinetics (including timedrive)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDNA\/Protein\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMulti-Wavelength\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerformance Validation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan\u003eSoftware and PC Control\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLocal control with wipe-clean membrane keypad\u003c\/li\u003e\n\u003cli\u003eRemote control via PC CamSpec UV-Vis Analyst application software\u003c\/li\u003e\n\u003cli\u003eUSB output for the transfer of results\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cstrong\u003ePharmacopoeias \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe CamSpec M550 passes the following pharmacopoeia tests:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePotassium Chloride stray light test\u003c\/li\u003e\n\u003cli\u003eToluene in Hexane resolution test\u003c\/li\u003e\n\u003cli\u003eHolmium Perchlorate solution wavelength test\u003c\/li\u003e\n\u003cli\u003ePotassium Dichromate absorbance test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"fl-callout-title\"\u003e\u003cspan class=\"fl-callout-title-text\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"fl-callout-text-wrap\"\u003e\n\u003cdiv class=\"fl-callout-text\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable id=\"tablepress-8\" class=\"tablepress tablepress-id-8\"\u003e\n\u003ctbody class=\"row-striping row-hover\"\u003e\n\u003ctr class=\"row-1\"\u003e\n\u003ctd class=\"column-1\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eGraphic LCD (320×240 )dot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-2\"\u003e\n\u003ctd class=\"column-1\"\u003eLight Source\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eTungsten-Halogen and Deuterium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3\"\u003e\n\u003ctd class=\"column-1\"\u003eMonochromator\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eDouble beam, grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4\"\u003e\n\u003ctd class=\"column-1\"\u003eDetectors\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eSilicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5\"\u003e\n\u003ctd class=\"column-1\"\u003eWavelenth Range\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e190-1100nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6\"\u003e\n\u003ctd class=\"column-1\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e±0.5nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7\"\u003e\n\u003ctd class=\"column-1\"\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e≤0.1nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8\"\u003e\n\u003ctd class=\"column-1\"\u003eWavelength Resolution\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e±0.1nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9\"\u003e\n\u003ctd class=\"column-1\"\u003eStability\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e±0.0005Abs@500nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10\"\u003e\n\u003ctd class=\"column-1\"\u003eSample Compartment\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eVarious Accessories Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11\"\u003e\n\u003ctd class=\"column-1\"\u003eStandard Cell Holder\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e1 Sample; 1 Reference for 10mm cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12\"\u003e\n\u003ctd class=\"column-1\"\u003eSoftware\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eUV-Vis Analyst, optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13\"\u003e\n\u003ctd class=\"column-1\"\u003eZero Drift\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u0026lt;0.001A per hour after warm up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14\"\u003e\n\u003ctd class=\"column-1\"\u003eBandpass\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u0026lt;1.8nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15\"\u003e\n\u003ctd class=\"column-1\"\u003eStray Light\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u0026lt;0.1%@220nm\u0026amp;340nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16\"\u003e\n\u003ctd class=\"column-1\"\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17\"\u003e\n\u003ctd class=\"column-1\"\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0-200%T, -0.3-3.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-18\"\u003e\n\u003ctd class=\"column-1\"\u003ePrinter Interface\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eParallel for A4 HP and Epson Printers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-19\"\u003e\n\u003ctd class=\"column-1\"\u003eComputer Interface\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eUSB for PC control and USB for data export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-20\"\u003e\n\u003ctd class=\"column-1\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e100V-240V AC, 50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-21\"\u003e\n\u003ctd class=\"column-1\"\u003eInstrument Dimensions (lxwxh)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e405x625x280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-22\"\u003e\n\u003ctd class=\"column-1\"\u003eInstrument Weight\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e24.0kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-23\"\u003e\n\u003ctd class=\"column-1\"\u003eShipping Dimensions (lxwxh)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e770x580x420mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-24\"\u003e\n\u003ctd class=\"column-1\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e26.7kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Non GMP Compliant","offer_id":58588326756677,"sku":"M550 1.8nm","price":7345.0,"currency_code":"GBP","in_stock":true},{"title":"GMP Compliant","offer_id":58588326789445,"sku":"M550 1.8nm GMP","price":7895.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/M550.jpg?v=1784232696","url":"https:\/\/auckland-scientific.co.uk\/products\/camspec-m550-double-beam-scanning-uv-vis-spectrophotometer-1-8nm-bandpass","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}