{"product_id":"daeil-dvid-l-passive-vibration-isolation-lab-workstation","title":"DAEIL DVID-L Passive Vibration Isolation Lab Workstation","description":"\u003ch2 style=\"color:#005f91;\"\u003eDAEIL DVID-L Passive Vibration Isolation Lab Workstation\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDVID-L\u003c\/strong\u003e is an all-in-one laboratory workstation combining a pneumatically isolated precision work surface with an ergonomic operator workspace. It is particularly useful where sensitive microscopy, inspection or measurement equipment must sit close to computers, controllers and other peripherals without allowing those items to feed vibration back into the instrument.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eWhy Choose the DVID-L?\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecoupled workspace:\u003c\/strong\u003e the auxiliary side workspace can be mechanically separated from the vibration-isolated zone, allowing computers, monitors and power supplies to remain close to the operator without disturbing the instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErgonomic operation:\u003c\/strong\u003e open-front frame and available front armrest support seated work and delicate manual adjustments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom engineered:\u003c\/strong\u003e width, depth, workspace position and heavy-duty configuration can be adapted around the equipment footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated mobility:\u003c\/strong\u003e casters allow positioning while the levelling system establishes the working height.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eIsolation Performance\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003ePneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eHigh-precision configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e1.5–3 Hz natural frequency; 80–99% isolation at 10 Hz; up to 300 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eDynamic-stability configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e4–8 Hz natural frequency; 80–99% isolation at 20 Hz; up to 600 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eLevelling repeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e±1.0 mm standard; optional ±0.05 mm precision levelling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;\"\u003e\u003cstrong\u003eAir supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e4–6 bar, 10 L\/min, Ø6 mm pneumatic fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTypical Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOptical and research microscopes\u003c\/li\u003e\n\u003cli\u003eWhite-light interferometry and surface metrology\u003c\/li\u003e\n\u003cli\u003eProbe stations and semiconductor inspection\u003c\/li\u003e\n\u003cli\u003eMicrobalances and precision weighing\u003c\/li\u003e\n\u003cli\u003eCell injection and manipulation\u003c\/li\u003e\n\u003cli\u003eOptical lithography and fine positioning experiments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration note:\u003c\/strong\u003e DVID-L systems are custom-engineered. Please provide the instrument footprint, total load and preferred workspace arrangement when requesting a quotation.\u003c\/p\u003e\u003cdiv style=\"border-left:4px solid #005f91;background:#eef7fb;padding:16px;margin:20px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help selecting the correct configuration?\u003c\/strong\u003e\u003cp\u003eSend Auckland Scientific your instrument model, footprint, weight and installation conditions. We can help select the appropriate DAEIL configuration and provide a quotation.\u003c\/p\u003e\n\u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eRequest a Quote\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv style=\"border:1px solid #d6e5ed;background:#f7fbfd;padding:16px;margin:20px 0;border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#005f91;\"\u003eOfficial DAEIL Literature\u003c\/strong\u003e\n  \u003cp\u003eOfficial DAEIL SYSTEMS product literature covering the passive vibration-isolation range, specifications and applications.\u003c\/p\u003e\n  \u003ca href=\"https:\/\/www.daeilsys.com\/support\/resources\/catalogs\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eView DAEIL Product Catalog\u003c\/a\u003e\n  \u003c\/div\u003e\u003cdiv data-auckland-quote-block=\"true\" style=\"border:2px solid #005f91;background:#eef7fb;padding:18px;margin:24px 0;border-radius:6px;\"\u003e\n  \u003ch3 style=\"color:#005f91;margin-top:0;\"\u003eRequest a Quote\u003c\/h3\u003e\n  \u003cp\u003eThis product is supplied on a quotation basis. Contact Auckland Scientific with your application, required specification and delivery location and we will provide advice and pricing.\u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eSend an Enquiry\u003c\/a\u003e\n    \u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk?subject=Quote%20request%3A%20DAEIL%20DVID-L%20Passive%20Vibration%20Isolation%20Lab%20Workstation\u0026amp;body=Hello%20Michael%2C%0A%0AI%20would%20like%20a%20quotation%20for%20DAEIL%20DVID-L%20Passive%20Vibration%20Isolation%20Lab%20Workstation.%0A%0APlease%20contact%20me%20to%20discuss%20my%20requirements.%0A%0AName%3A%0ACompany%3A%0ATelephone%3A%0ADelivery%20location%3A%0AApplication%20%2F%20specification%20required%3A%0A\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eEmail Michael\u003c\/a\u003e\n    \u003ca href=\"tel:+447853690001\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 0 8px 0;\"\u003eCall 07853 690001\u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp style=\"margin-bottom:0;\"\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e michael.hallewell@auckland-scientific.co.uk\u003cbr\u003e\u003cstrong\u003eTelephone:\u003c\/strong\u003e 07853 690001\u003c\/p\u003e\n\u003c\/div\u003e","brand":"DAEIL SYSTEMS","offers":[{"title":"Integrated Armrest","offer_id":59793580654917,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true},{"title":"Separated Workspace","offer_id":59793580687685,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/dvid-l.webp?v=1792245951","url":"https:\/\/auckland-scientific.co.uk\/products\/daeil-dvid-l-passive-vibration-isolation-lab-workstation","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}