{"product_id":"daeil-dvip-b-pneumatic-isolation-base","title":"DAEIL DVIP-B Pneumatic Isolation Base","description":"\u003ch2 style=\"color:#005f91;\"\u003eDAEIL DVIP-B Pneumatic Isolation Base\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDVIP-B\u003c\/strong\u003e is a low-profile, custom-engineered pneumatic isolation base for heavy precision instruments including SEM, TEM and metrology systems. Rather than forcing a large instrument onto a standard table, the platform is designed around the exact footprint, load distribution and support points of the equipment.\u003c\/p\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eDesigned Around the Instrument\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom equipment interface:\u003c\/strong\u003e chassis geometry is matched to instrument dimensions, mass distribution, caster points and mounting positions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-profile architecture:\u003c\/strong\u003e keeps tall or heavy tools close to their intended operating height.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh centre-of-gravity stability:\u003c\/strong\u003e useful for electron-microscope columns and other tall precision systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless-steel top surface:\u003c\/strong\u003e durable precision equipment interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision levelling option:\u003c\/strong\u003e ±0.05 mm repeatability where required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#005f91;\"\u003ePerformance\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eIsolation method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003ePneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003eResonant frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e1.2–3.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003ePublished isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e80–99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e\u003cstrong\u003ePayload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #d9e3e8;\"\u003e400–6,000 kg, custom-engineered to the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;\"\u003e\u003cstrong\u003eLevelling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e±1.0 mm standard; ±0.05 mm precision option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"color:#005f91;\"\u003eTypical Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eScanning electron microscopes (SEM)\u003c\/li\u003e\n\u003cli\u003eTransmission electron microscopes (TEM)\u003c\/li\u003e\n\u003cli\u003eHeavy optical and surface-metrology equipment\u003c\/li\u003e\n\u003cli\u003ePrecision inspection tools with a demanding floor-vibration specification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuotation information:\u003c\/strong\u003e please provide instrument make\/model, total weight, footprint, caster or support-point locations and, where available, the manufacturer's floor-vibration requirement.\u003c\/p\u003e\u003cdiv style=\"border-left:4px solid #005f91;background:#eef7fb;padding:16px;margin:20px 0;\"\u003e\n\u003cstrong style=\"color:#005f91;\"\u003eNeed help selecting the correct configuration?\u003c\/strong\u003e\u003cp\u003eSend Auckland Scientific your instrument model, footprint, weight and installation conditions. We can help select the appropriate DAEIL configuration and provide a quotation.\u003c\/p\u003e\n\u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eRequest a Quote\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv style=\"border:1px solid #d6e5ed;background:#f7fbfd;padding:16px;margin:20px 0;border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#005f91;\"\u003eOfficial DAEIL Literature\u003c\/strong\u003e\n  \u003cp\u003eOfficial DAEIL SYSTEMS product literature covering the passive vibration-isolation range, specifications and applications.\u003c\/p\u003e\n  \u003ca href=\"https:\/\/www.daeilsys.com\/support\/resources\/catalogs\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;\"\u003eView DAEIL Product Catalog\u003c\/a\u003e\n  \u003c\/div\u003e\u003cdiv data-auckland-quote-block=\"true\" style=\"border:2px solid #005f91;background:#eef7fb;padding:18px;margin:24px 0;border-radius:6px;\"\u003e\n  \u003ch3 style=\"color:#005f91;margin-top:0;\"\u003eRequest a Quote\u003c\/h3\u003e\n  \u003cp\u003eThis product is supplied on a quotation basis. Contact Auckland Scientific with your application, required specification and delivery location and we will provide advice and pricing.\u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/auckland-scientific.co.uk\/pages\/contact\" style=\"display:inline-block;background:#005f91;color:#ffffff!important;padding:11px 18px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eSend an Enquiry\u003c\/a\u003e\n    \u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk?subject=Quote%20request%3A%20DAEIL%20DVIP-B%20Pneumatic%20Isolation%20Base\u0026amp;body=Hello%20Michael%2C%0A%0AI%20would%20like%20a%20quotation%20for%20DAEIL%20DVIP-B%20Pneumatic%20Isolation%20Base.%0A%0APlease%20contact%20me%20to%20discuss%20my%20requirements.%0A%0AName%3A%0ACompany%3A%0ATelephone%3A%0ADelivery%20location%3A%0AApplication%20%2F%20specification%20required%3A%0A\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 8px 8px 0;\"\u003eEmail Michael\u003c\/a\u003e\n    \u003ca href=\"tel:+447853690001\" style=\"display:inline-block;background:#ffffff;color:#005f91!important;border:1px solid #005f91;padding:10px 17px;text-decoration:none;border-radius:4px;font-weight:600;margin:0 0 8px 0;\"\u003eCall 07853 690001\u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp style=\"margin-bottom:0;\"\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e michael.hallewell@auckland-scientific.co.uk\u003cbr\u003e\u003cstrong\u003eTelephone:\u003c\/strong\u003e 07853 690001\u003c\/p\u003e\n\u003c\/div\u003e","brand":"DAEIL SYSTEMS","offers":[{"title":"Custom instrument platform","offer_id":59793587470661,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/dvip-b.webp?v=1792246027","url":"https:\/\/auckland-scientific.co.uk\/products\/daeil-dvip-b-pneumatic-isolation-base","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}