{"product_id":"evident-lext-ols5500-3d-optical-profilometer","title":"Evident LEXT OLS5500 3D Optical Profilometer","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#243746;font-size:15px;line-height:1.7;\"\u003e\n \u003cdiv style=\"background:linear-gradient(125deg,#102a43 0%,#075b82 65%,#087f96 100%);padding:27px 25px;border-radius:12px;color:#fff;margin-bottom:20px;\"\u003e\n \u003cp style=\"margin:0 0 7px;color:#d8f4ff;font-size:12px;letter-spacing:1.2px;font-weight:bold;\"\u003eEVIDENT | INDUSTRIAL MICROSCOPY\u003c\/p\u003e\n \u003ch2 style=\"color:#fff;font-size:27px;line-height:1.3;margin:0 0 12px;\"\u003eLEXT OLS5500 3D Optical Profilometer\u003c\/h2\u003e\n\u003cp style=\"color:#fff;font-size:16px;\"\u003eA non-contact surface-measurement platform combining confocal laser scanning with configurable focus-variation and white-light-interferometry capabilities. The LEXT OLS5500 is designed for detailed three-dimensional surface examination and quantitative analysis.\u003c\/p\u003e\n \u003cspan style=\"border:1px solid #b9dceb;border-radius:20px;padding:5px 12px;font-size:12px;color:#fff;\"\u003ePrice on Request\u003c\/span\u003e\n\u003c\/div\u003e\n \u003cdiv style=\"padding:20px;border:1px solid #c8dce9;background:#f0f7fb;border-radius:10px;margin:20px 0;\"\u003e\n\u003ch3 style=\"color:#075b82;margin:0 0 7px;\"\u003eSpeak to a Microscopy Specialist\u003c\/h3\u003e\n\u003cp\u003eMichael Hallewell offers over 21 years of microscopy experience. Discuss your specimens, workflow and imaging requirements so we can specify a suitable OLS5500 system.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact?product=Evident%20LEXT%20OLS5500%203D%20Optical%20Profilometer\" style=\"display:inline-block;background:#075b82;color:#fff!important;padding:12px 17px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003eDiscuss Your OLS5500 Configuration →\u003c\/a\u003e\n\u003c\/div\u003e\n \u003ch3 style=\"margin:28px 0 12px;padding:11px 15px;background:#075b82;color:#fff;border-radius:7px;font-size:20px;\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(215px,1fr));gap:13px;margin:18px 0;\"\u003e\n\u003cdiv style=\"background:#f3f8fb;border:1px solid #d7e5ed;border-radius:9px;padding:18px;\"\u003e\n\u003cstrong style=\"color:#075b82;\"\u003eChoose the measurement method\u003c\/strong\u003e\u003cp style=\"margin:8px 0 0;\"\u003eLaser scanning, focus variation and white-light interferometry address different surface tasks; available functions depend on hardware and software configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f3f8fb;border:1px solid #d7e5ed;border-radius:9px;padding:18px;\"\u003e\n\u003cstrong style=\"color:#075b82;\"\u003eMatch the frame to the specimen\u003c\/strong\u003e\u003cp style=\"margin:8px 0 0;\"\u003eStandard, extended-height and large-stage variants provide different clearance and movement ranges.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f3f8fb;border:1px solid #d7e5ed;border-radius:9px;padding:18px;\"\u003e\n\u003cstrong style=\"color:#075b82;\"\u003eDedicated measurement optics\u003c\/strong\u003e\u003cp style=\"margin:8px 0 0;\"\u003eSelect appropriate LEXT objectives and working distances for the surface and measurement method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f3f8fb;border:1px solid #d7e5ed;border-radius:9px;padding:18px;\"\u003e\n\u003cstrong style=\"color:#075b82;\"\u003eApplication-led configuration\u003c\/strong\u003e\u003cp style=\"margin:8px 0 0;\"\u003eDiscuss roughness, topography, step-height or other analysis requirements before choosing the system and software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003ch3 style=\"margin:28px 0 12px;padding:11px 15px;background:#075b82;color:#fff;border-radius:7px;font-size:20px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#eaf3f8;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003eManufacturer \/ model\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003eEvident (Olympus microscopy) \/ OLS5500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003eMain-unit variants\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003eOLS5500-SAF, OLS5500-EAF, OLS5500-LAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#eaf3f8;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003ePublished total magnification range\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003e54×–17,280×; configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003ePublished field-of-view range\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003e16 µm–5,120 µm; configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#eaf3f8;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003eLaser wavelength\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003e405 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003eColour illumination\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003eWhite LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#eaf3f8;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003eSAF \/ EAF motorised XY travel\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003e100 × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003eLAF motorised XY travel\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003e300 × 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#eaf3f8;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003eMaximum sample height\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003eSAF: 100 mm; EAF: 210 mm; LAF: 37 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003eMaximum points in one measurement\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003e4096 × 4096 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#eaf3f8;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003eWLI configuration\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003eSeparate hardware\/software requirements and 68 mm sample-height limit; confirm selected system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003ePerformance specification\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003eAccuracy and repeatability depend on objective, method and specified environmental conditions; refer to the official brochure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#eaf3f8;\"\u003e\n\u003cth scope=\"row\" style=\"width:35%;padding:12px;border:1px solid #cbdce7;text-align:left;color:#075b82;\"\u003ePricing\u003c\/th\u003e\n\u003ctd style=\"padding:12px;border:1px solid #cbdce7;\"\u003ePrice on Request — configured to your application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n \u003cp style=\"font-size:13px;color:#637487;\"\u003eManufacturer specifications describe the stated model and optical combinations. Optional accessories are not included unless itemised in your quotation. Manufacturer photographs may show optional accessories and alternative configurations.\u003c\/p\u003e\n \u003ch3 style=\"margin:28px 0 12px;padding:11px 15px;background:#075b82;color:#fff;border-radius:7px;font-size:20px;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eSurface topography, materials research, semiconductor and electronics inspection, and quantitative surface analysis.\u003c\/p\u003e\n \u003ch3 style=\"margin:28px 0 12px;padding:11px 15px;background:#075b82;color:#fff;border-radius:7px;font-size:20px;\"\u003eConfigure Your OLS5500\u003c\/h3\u003e\n\u003cp\u003eProvide sample dimensions, surface material, expected height range and measurement requirements. We will confirm the appropriate frame, objectives, measurement modules and environmental requirements. Performance values are not interchangeable between measurement methods.\u003c\/p\u003e\n\u003cp\u003eYour quotation will identify the microscope body, optical components, illumination and any imaging accessories, together with delivery, installation and training arrangements. Please include existing equipment details if you need to reuse components.\u003c\/p\u003e\n \u003ch3 style=\"margin:28px 0 12px;padding:11px 15px;background:#075b82;color:#fff;border-radius:7px;font-size:20px;\"\u003eEvident Technical Resources\u003c\/h3\u003e\n\u003cp\u003eUse Auckland Scientific's Technical Resource Centre to review the manufacturer literature and supporting resources before choosing your configuration.\u003c\/p\u003e\n \u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:13px;margin:18px 0;\"\u003e\n \u003cdiv style=\"background:#f3f8fb;border:1px solid #d7e5ed;border-radius:10px;padding:20px;\"\u003e\n\u003ch4 style=\"color:#075b82;margin:0 0 10px;\"\u003eOfficial OLS5500 Brochure\u003c\/h4\u003e\n\u003cp\u003eReview model information, optical options and the manufacturer system specifications.\u003c\/p\u003e\n\u003ca href=\"https:\/\/downloads.auckland-scientific.co.uk\/evident\/brochures\/LEXT%20OLS5500%20Brochure.pdf\" style=\"display:inline-block;background:#075b82;color:#fff!important;padding:12px 17px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003eView \/ Download Brochure →\u003c\/a\u003e\n\u003c\/div\u003e\n \u003cdiv style=\"background:#f3f8fb;border:1px solid #d7e5ed;border-radius:10px;padding:20px;\"\u003e\n\u003ch4 style=\"color:#075b82;margin:0 0 10px;\"\u003eVideo Library\u003c\/h4\u003e\n\u003cp\u003eBrowse the industrial microscopy video library; individual model videos depend on availability.\u003c\/p\u003e\n\u003ca href=\"https:\/\/downloads.auckland-scientific.co.uk\/evident\/videos\/\" style=\"display:inline-block;background:#075b82;color:#fff!important;padding:12px 17px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003eBrowse Manufacturer Videos →\u003c\/a\u003e\n\u003c\/div\u003e\n \u003cdiv style=\"background:#f3f8fb;border:1px solid #d7e5ed;border-radius:10px;padding:20px;\"\u003e\n\u003ch4 style=\"color:#075b82;margin:0 0 10px;\"\u003eObjective Selection\u003c\/h4\u003e\n\u003cp\u003eExplore objective parameters in our Objective Finder. Compatibility, contrast accessories and the final optical configuration will be confirmed before supply.\u003c\/p\u003e\n\u003ca href=\"https:\/\/downloads.auckland-scientific.co.uk\/evident\/objective-finder\/\" style=\"display:inline-block;background:#075b82;color:#fff!important;padding:12px 17px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003eOpen Objective Finder →\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/downloads.auckland-scientific.co.uk\/evident\/\" style=\"display:inline-block;background:#075b82;color:#fff!important;padding:12px 17px;border-radius:6px;text-decoration:none;font-weight:bold;\"\u003eVisit Evident Technical Resources →\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- AUCKLAND SCIENTIFIC SUPPORT --\u003e\n\n\u003ch3 style=\"margin:28px 0 12px;padding:11px 15px;background:#075b82;color:#ffffff;border-radius:7px;font-size:20px;\"\u003e\nWhy Choose Auckland Scientific?\n\u003c\/h3\u003e\n\n\u003cp\u003e\nAuckland Scientific is a UK-based, family-run supplier of microscopes, scientific instruments and specialist laboratory equipment.\n\u003c\/p\u003e\n\n\u003cp\u003e\nWith \u003cstrong\u003eover 21 years of experience in microscopy and scientific instrumentation\u003c\/strong\u003e, Michael Hallewell provides personal technical support to help customers select the right microscope for their application.\n\u003c\/p\u003e\n\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(200px,1fr));gap:12px;margin:18px 0;\"\u003e\n\n\u003cdiv style=\"padding:16px;background:#eef6fa;border-radius:8px;border:1px solid #d4e4ed;\"\u003e\n\u003cstrong style=\"color:#075b82;\"\u003eExpert Advice\u003c\/strong\u003e\n\u003cp style=\"margin:6px 0 0;\"\u003ePersonal assistance with equipment selection and configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:16px;background:#eef6fa;border-radius:8px;border:1px solid #d4e4ed;\"\u003e\n\u003cstrong style=\"color:#075b82;\"\u003eInstallation\u003c\/strong\u003e\n\u003cp style=\"margin:6px 0 0;\"\u003eInstallation and commissioning services available throughout the UK.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:16px;background:#eef6fa;border-radius:8px;border:1px solid #d4e4ed;\"\u003e\n\u003cstrong style=\"color:#075b82;\"\u003eTraining\u003c\/strong\u003e\n\u003cp style=\"margin:6px 0 0;\"\u003ePractical user training and microscope application guidance.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:16px;background:#eef6fa;border-radius:8px;border:1px solid #d4e4ed;\"\u003e\n\u003cstrong style=\"color:#075b82;\"\u003eAfter-Sales Support\u003c\/strong\u003e\n\u003cp style=\"margin:6px 0 0;\"\u003eServicing, preventative maintenance and calibration support where applicable.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- PREMIUM QUOTATION AND CONSULTATION PANEL --\u003e\n\n\u003cdiv style=\"background:linear-gradient(135deg,#102a43 0%,#143d59 55%,#075b82 100%);color:#ffffff;padding:32px 26px;border-radius:14px;margin:32px 0 22px;overflow:hidden;\"\u003e\n\n\u003cp style=\"font-size:12px;letter-spacing:1.5px;font-weight:700;text-transform:uppercase;color:#9edceb;margin:0 0 10px;\"\u003e\nAUCKLAND SCIENTIFIC | PERSONALISED MICROSCOPE SOLUTIONS\n\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:29px;line-height:1.25;color:#ffffff;margin:0 0 12px;\"\u003e\nConfigure Your Evident OLS5500\n\u003c\/h2\u003e\n\n\u003cp style=\"font-size:17px;color:#e3f1f8;margin:0 0 23px;max-width:760px;\"\u003e\nA precision microscope deserves a configuration tailored to your workplace. Discuss your application directly with an experienced microscopy specialist.\n\u003c\/p\u003e\n\n\u003c!-- CONSULTATION BENEFITS --\u003e\n\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(230px,1fr));gap:14px;margin:0 0 25px;\"\u003e\n\n\u003cdiv style=\"background:#1b425a;border:1px solid #3c6176;border-radius:10px;padding:19px;\"\u003e\n\n\u003cp style=\"color:#bce7f6;font-size:12px;font-weight:700;letter-spacing:1px;text-transform:uppercase;margin:0 0 7px;\"\u003e\nTAILORED CONFIGURATION\n\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffffff;font-size:18px;margin:0 0 9px;\"\u003e\nYour Microscope, Your Requirements\n\u003c\/h3\u003e\n\n\u003cp style=\"color:#d8eaf2;font-size:14px;margin:0;\"\u003e\nDiscuss suitable objectives, observation techniques, illumination, digital imaging, installation and training.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#1b425a;border:1px solid #3c6176;border-radius:10px;padding:19px;\"\u003e\n\n\u003cp style=\"color:#bce7f6;font-size:12px;font-weight:700;letter-spacing:1px;text-transform:uppercase;margin:0 0 7px;\"\u003e\nSPECIALIST UK SUPPORT\n\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffffff;font-size:18px;margin:0 0 9px;\"\u003e\nPersonal Advice from Michael\n\u003c\/h3\u003e\n\n\u003cp style=\"color:#d8eaf2;font-size:14px;margin:0;\"\u003e\nBenefit from over 21 years of microscopy experience, with practical advice and ongoing technical support.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- PRIMARY QUOTATION CTA --\u003e\n\n\u003cdiv style=\"background:#ffffff;border-radius:10px;padding:22px 20px;text-align:center;\"\u003e\n\n\u003ch3 style=\"font-size:20px;color:#123a55;margin:0 0 8px;\"\u003e\nLet's Find the Right OLS5500 for Your Application\n\u003c\/h3\u003e\n\n\u003cp style=\"font-size:14px;color:#526879;margin:0 0 17px;\"\u003e\nTell us what you need and we'll help you develop a suitable microscope configuration and quotation.\n\u003c\/p\u003e\n\n\u003ca href=\"\/pages\/contact?product=Evident%20LEXT%20OLS5500%203D%20Optical%20Profilometer\" style=\"display:block;max-width:520px;margin:0 auto;background:#075b82;color:#ffffff!important;text-decoration:none;text-align:center;padding:16px 20px;border-radius:7px;font-weight:700;font-size:17px;\"\u003e\nRequest Your Personalised Quotation →\n\u003c\/a\u003e\n\n\u003cp style=\"font-size:12px;color:#64748b;margin:12px 0 0;\"\u003e\nYour quotation form will automatically include the Evident OLS5500 product details.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- DIRECT CONTACT --\u003e\n\n\u003cdiv style=\"border-top:1px solid #477087;margin-top:25px;padding-top:21px;\"\u003e\n\n\u003cp style=\"font-weight:700;color:#ffffff;margin:0 0 12px;font-size:16px;\"\u003e\nPrefer a conversation?\n\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:11px;\"\u003e\n\n\u003ca href=\"tel:+447853690001\" style=\"display:inline-block;background:transparent;border:1px solid #b9dceb;color:#ffffff!important;padding:12px 18px;text-decoration:none;border-radius:6px;font-weight:700;\"\u003e\n☎ Call Michael: 07853 690001\n\u003c\/a\u003e\n\n\u003ca href=\"mailto:michael.hallewell@auckland-scientific.co.uk?subject=Evident%20OLS5500%20Microscope%20Enquiry\" style=\"display:inline-block;background:transparent;border:1px solid #b9dceb;color:#ffffff!important;padding:12px 18px;text-decoration:none;border-radius:6px;font-weight:700;\"\u003e\n✉ Email Michael\n\u003c\/a\u003e\n\n\u003c\/div\u003e\n\n\u003cp style=\"font-size:13px;color:#c8e0ed;margin:17px 0 0;\"\u003e\nAuckland Scientific Ltd | UK Technical Advice | Installation | Training | After-Sales Support\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- PRODUCT DISCLAIMER --\u003e\n\n\u003cp style=\"font-size:12px;color:#637487;margin:17px 0;\"\u003e\n\u003cstrong\u003eProduct information:\u003c\/strong\u003e Specifications and available options depend on the selected configuration and may be changed by the manufacturer. Photographs may show optional accessories. Prices, lead times, delivery, warranty and installation arrangements will be confirmed in your written quotation.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n","brand":"Evident","offers":[{"title":"Default Title","offer_id":60124311585093,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/media_1eb797aaee250514975789d15ccea22cf393631a3.jpg?v=1794078681","url":"https:\/\/auckland-scientific.co.uk\/products\/evident-lext-ols5500-3d-optical-profilometer","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}