{"product_id":"m501-single-beam-scanning-uv-vis-spectrophotometer-with-2nm-or-4nm-bandpass-options","title":"Camspec M501 Single Beam Scanning UV Vis Spectrophotometer with 2nm or 4nm Bandpass Options","description":"\u003ch1\u003eCamspec M501 Single Beam Scanning\u003c\/h1\u003e\n\u003ch1\u003eUV Vis Spectrophotometer with 2nm or 4nm Bandpass Options for research and routine use\u003c\/h1\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/youtu.be\/JHzJueqwFUQ\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/Camspec_pic.jpg?v=1784482715\" alt=\"\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/youtu.be\/JHzJueqwFUQ\"\u003eClick to watch Spectrophometers Overview Video\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eModels available with either 2nm or 4nm bandpass.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLocal or remote control via PC software and USB interface for transfer of results.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eComplies with UKCA and CE requirements for safety and ESD\/EMC emission and susceptibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eExceptional sensitivity, resolution, stray light, noise and drift specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLarge range of accessories for laboratory automation and specific tests.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCalibrated in the UK by qualified engineers using international standards for wavelength, absorbance, resolution and stray light.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"fl-module fl-module-rich-text fl-node-6114fa283444a\" data-node=\"6114fa283444a\"\u003e\n\u003cdiv class=\"fl-module-content fl-node-content\"\u003e\n\u003cdiv class=\"fl-rich-text\"\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cstrong\u003eOperating Modes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBasic Mode (Abs, %T, Conc)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQuantitative (concentration calibration curves)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eWavelength \u003c\/span\u003e\u003cspan\u003eScanning \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKinetics (including timedrive)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDNA \/ Protein\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eMulti-wavelength\u003c\/li\u003e\n\u003cli\u003ePerformance Validation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan\u003eSoftware and PC Control\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLocal control with wipe-clean membrane keypad\u003c\/li\u003e\n\u003cli\u003eRemote control via PC CamSpec UV-Vis Analyst application software\u003c\/li\u003e\n\u003cli\u003eUSB output for the transfer of results\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cstrong\u003ePharmacopoeias \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe CamSpec M209T passes the following pharmacopoeia tests:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePotassium Chloride stray light test\u003c\/li\u003e\n\u003cli\u003eToluene in Hexane resolution test\u003c\/li\u003e\n\u003cli\u003eHolmium Perchlorate solution wavelength test\u003c\/li\u003e\n\u003cli\u003ePotassium Dichromate absorbance test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fl-module fl-module-callout fl-node-6114fa283442b\" data-node=\"6114fa283442b\"\u003e\n\u003cdiv class=\"fl-module-content fl-node-content\"\u003e\n\u003cdiv class=\"fl-callout fl-callout-has-photo fl-callout-photo-above-title\"\u003e\n\u003cdiv class=\"fl-callout-content\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"fl-callout-content\"\u003e\n\u003ch2 class=\"fl-callout-title\"\u003e\u003cspan class=\"fl-callout-title-text\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable id=\"tablepress-7\" class=\"tablepress tablepress-id-7\"\u003e\n\u003ctbody class=\"row-striping row-hover\"\u003e\n\u003ctr class=\"row-1\"\u003e\n\u003ctd class=\"column-1\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eGraphic LED Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-2\"\u003e\n\u003ctd class=\"column-1\"\u003eLight Source\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eTungsten-Halogen and Deuterium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3\"\u003e\n\u003ctd class=\"column-1\"\u003eMonochromator\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eSingle beam, grating 1200 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4\"\u003e\n\u003ctd class=\"column-1\"\u003eDetectors\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eSilicon Photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5\"\u003e\n\u003ctd class=\"column-1\"\u003eWavelenth Range\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e190-1100nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6\"\u003e\n\u003ctd class=\"column-1\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e±1.0nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7\"\u003e\n\u003ctd class=\"column-1\"\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e≤0.2nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8\"\u003e\n\u003ctd class=\"column-1\"\u003eWavelength Resolution\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e±0.2nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9\"\u003e\n\u003ctd class=\"column-1\"\u003eStability\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e±0.0005Abs@500nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10\"\u003e\n\u003ctd class=\"column-1\"\u003eSample Compartment\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eFits 100mm path length cuvette with optional holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11\"\u003e\n\u003ctd class=\"column-1\"\u003eStandard Cell Holder\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e4 position 10mm cell changer \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12\"\u003e\n\u003ctd class=\"column-1\"\u003eSoftware\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eUV-Vis Analyst, optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13\"\u003e\n\u003ctd class=\"column-1\"\u003eZero Drift\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u0026lt;0.003A per hour after warm up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14\"\u003e\n\u003ctd class=\"column-1\"\u003eBandpass\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e2nm or 4nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15\"\u003e\n\u003ctd class=\"column-1\"\u003eStray Light\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u0026lt;0.1% @ 220nm\u0026amp;340nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16\"\u003e\n\u003ctd class=\"column-1\"\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17\"\u003e\n\u003ctd class=\"column-1\"\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0-200%T,-0.3-.2.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-18\"\u003e\n\u003ctd class=\"column-1\"\u003ePrinter Interface\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eBluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-19\"\u003e\n\u003ctd class=\"column-1\"\u003eComputer Interface\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eUSB for PC control and USB for data export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-20\"\u003e\n\u003ctd class=\"column-1\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e100V-240V AC, 50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-21\"\u003e\n\u003ctd class=\"column-1\"\u003eInstrument Dimensions (lxwxh)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e420x550x270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-22\"\u003e\n\u003ctd class=\"column-1\"\u003eInstrument Weight \u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e18.0kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-23\"\u003e\n\u003ctd class=\"column-1\"\u003eShipping Dimensions (lxwxh)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e660x550x390mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-24\"\u003e\n\u003ctd class=\"column-1\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e19.3kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fl-module fl-module-rich-text fl-node-6114fa2834432\" data-node=\"6114fa2834432\"\u003e\n\u003cdiv class=\"fl-module-content fl-node-content\"\u003e\n\u003cdiv class=\"fl-rich-text\"\u003e\u003chr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fl-col-group fl-node-6114fa283443c fl-col-group-nested\" data-node=\"6114fa283443c\"\u003e\n\u003cdiv class=\"fl-col fl-node-6114fa283443d fl-col-bg-color\" data-node=\"6114fa283443d\"\u003e\n\u003cdiv class=\"fl-col-content fl-node-content\"\u003e\n\u003cdiv class=\"fl-module fl-module-callout fl-node-6114fa283442a\" data-node=\"6114fa283442a\"\u003e\n\u003cdiv class=\"fl-module-content fl-node-content\"\u003e\n\u003cdiv class=\"fl-callout fl-callout-has-photo fl-callout-photo-above-title\"\u003e\n\u003cdiv class=\"fl-callout-content\"\u003e\n\u003cdiv class=\"fl-callout-text-wrap\"\u003e\n\u003cdiv class=\"fl-callout-text\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Accessories available to purchase\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CamSpec M501 has a large sample compartment that fits a selection of available \u003cbr\u003eaccessories for automation and specific tests.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eAdjustable Micro Cell Holder PART NO: 501-102\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/Adjustable_Micro_Cell_Holder.png?v=1783969238\" alt=\"\" width=\"170\" height=\"168\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003ePeltier\/Sipper System Combined PART NO: 501-124\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/peltier_sipper_system.png?v=1783969480\" alt=\"\" width=\"173\" height=\"135\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuckland Scientific also supply calibration standards, cuvettes, spare bulbs and servicing. \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"2nm Bandpass","offer_id":58588578185541,"sku":"M501 2nm","price":4195.0,"currency_code":"GBP","in_stock":true},{"title":"4nm Bandpass","offer_id":58588578218309,"sku":"M501 4nm","price":4043.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/M501_54f3f56f-916e-4ba5-9581-a40bc01fe4a6.jpg?v=1784236332","url":"https:\/\/auckland-scientific.co.uk\/products\/m501-single-beam-scanning-uv-vis-spectrophotometer-with-2nm-or-4nm-bandpass-options","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}