{"product_id":"milwaukee-mw170-max-ec-tds-nacl-temp-logging-bench-meter","title":"Milwaukee MW170 MAX EC\/TDS\/NaCl\/Temp Logging Bench Meter","description":"\u003ch1 class=\"productView-title\" itemprop=\"name\"\u003eMilwaukee MW170 MAX EC\/TDS\/NaCl\/Temp Logging Bench Meter\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003e\u003cstrong\u003eLab Grade. High Performance. Automated. Tough.\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe Milwaukee MW170 4-in-1 MAX EC\/TDS\/NaCl\/Temp. Logging Bench Meter has won fans around the world with its reliable, fast and simple operation as well as its tough, sleek design and small benchtop footprint. It is accurate to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"single-product-meta-item-value\"\u003e± 1% of reading for EC\/TDS \u0026amp; Salinity\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ewith automatic, manual or no temperature compensation and a built in dedicated GLP key. Ideal for use by education, horticulture, labs, food processing, water treatment and many other applications with challenging EC\/TDS\/NaCL\/Temp. measurement needs.\u003c\/p\u003e\n\u003ch2\u003eSummary\u003c\/h2\u003e\n\u003cp\u003eThe Milwaukee MW170 4-in-1 MAX EC\/TDS\/NaCl\/Temp Bench Logging Meter is preferred by people testing samples in various applications. The easy-to-use logging feature allows data collection without messy notes and errors. From aquaculture, environmental, research to educators, the MW170 MAX is your meter for fast, accurate readings.\u003c\/p\u003e\n\u003cp\u003eThe Milwaukee MW170 MAX EC\/TDS\/NaCl\/Temp. Bench meter offers:\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003ePeople choose the MW170 4-in-1 MAX EC\/TDS\/NaCl\/Temp Bench Logging Meter to improve the accuracy of their testing program. With easy 1 point EC calibration, 6 standard buffer choices and 2 point temperature calibration, the meter can be quickly calibrated to a higher temperature accuracy compared to other meters and it provides more accurate temperature compensation readings than a one point calibration. The MW170 MAX Bench Meter is accurate to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"single-product-meta-item-value\"\u003e±1% of reading for EC\/TDS and NaCL\u003c\/span\u003e. \u003c\/p\u003e\n\u003cp\u003eThe meter comes with MA814DB\/1 (4 ring) conductivity probe with a built in temperature sensor allowing the meter to automatically adjust the EC\/TDS\/NaCl reading for the effect of temperature (ATC).\u003c\/p\u003e\n\u003cp\u003eThe meter can also be used as a very accurate thermometer with accuracy ±0.5 °C (±0.9 °F)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eToughness\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe rugged meter is built to take knocks and has a sleek design that includes a small benchtop footprint .\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLow Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MW170 MAX EC\/TDS\/NaCl\/Temp Bench Logging Meter comes with the Milwaukee MA814DB\/1 combination EC\/Temp sensor. This is Milwaukee's top selling lab grade EC probe for a reason. Designed to be both low maintenance and able to withstand more challenging samples. The MA814DB\/1 is ideal for use in horticulture, aquaculture, environmental labs, water treatment\/conditioning and many other applications. \u003c\/p\u003e\n\u003ch2\u003eDesign features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFast easy to read results with large duel level digital LCD readout.\u003c\/li\u003e\n\u003cli\u003eExtreme accuracy to 1% of reading for EC\/TDS\/NaCl | ±0.5 °C (±0.9 °F). \u003c\/li\u003e\n\u003cli\u003eExtended auto-ranging feature for EC\/TDS\/NaCl.\u003c\/li\u003e\n\u003cli\u003eLightweight, sleek design featuring a small benchtop footprint.\u003c\/li\u003e\n\u003cli\u003eSimple easy-to-use logging; manual log-on-demand or manual log-on-stability up to 1,000 records.  \u003c\/li\u003e\n\u003cli\u003eMicro USB Port download functions. \u003c\/li\u003e\n\u003cli\u003eGLP data, date and time.\u003c\/li\u003e\n\u003cli\u003eEasy measurement: just place the probe in the sample, gently stir and wait for the reading to stabilize.\u003c\/li\u003e\n\u003cli\u003eSingle cell factor calibration for EC\/TDS\/NaCl, automatic simple one point calibration and two point for temperature allowing increased accuracy.\u003c\/li\u003e\n\u003cli\u003eRugged low maintenance, high performance, easy-to-clean EC\/TDS\/NaCL\/Temp probe.\u003c\/li\u003e\n\u003cli\u003eBuilt in temperature sensor. \u003c\/li\u003e\n\u003cli\u003eInternal clock date to keep track of different time-dependent functions (calibration, timestamp,calibration time out).\u003c\/li\u003e\n\u003cli\u003e3 feet probe cables for extra flexibility when testing.\u003c\/li\u003e\n\u003cli\u003eIncludes MA9315 electrode holder, cables, adapter and probe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eEC Range:\u003c\/strong\u003e\u003cspan\u003e 0.00 to 29.99 µS\/cm; 30.0 to 299.9 µS\/cm; 300 to 2999 µS\/cm; 3.00 to 29.99 mS\/cm; 30.0 to 200.0 mS\/cm; up to 500.0 mS\/cm absolute conductivity **\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTDS Range:\u003c\/strong\u003e\u003cspan\u003e 0.00 to 14.99 ppm (mg\/L); 15.0 to 149.9 ppm (mg\/L); 150 to 1499 ppm (mg\/L); 1.50 to 14.99 g\/L; 15.0 to 100.0 g\/L; up to 250.0 g\/L absolute TDS **; up to 400.0 g\/L absolute TDS ** (with 0.8 factor)\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSalinity Range:\u003c\/strong\u003e\u003cspan\u003e 0.0 to 400.0% NaCl \/ 2.00 to 42.00 PSU; 0.00 to 80.00 g\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTemp. Range:\u003c\/strong\u003e\u003cspan\u003e -20.0 to 120.00 °C (-4.0 to 248.0 °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eEC Resolution:\u003c\/strong\u003e\u003cspan\u003e 0.01 µS\/cm; 0.1 µS\/cm; 1 µS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTDS Resolution:\u003c\/strong\u003e\u003cspan\u003e 0.01 ppm; 0.1 ppm; 1 ppm; 0.01 g\/L; 0.1 g\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSalinity Resolution:\u003c\/strong\u003e\u003cspan\u003e 0.1% NaCl; 0.01 PSU; 0.01 g\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Resolution:\u003c\/strong\u003e\u003cspan\u003e 0.1 °C \/ 0.1 °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy @ 25 °C \/ 77 °F:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cspan\u003eEC: ±1% of reading \/ ±0.05 µS\/cm or 1 digit, whichever is greater\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cspan\u003eTDS: ±1% of reading \/ ±0.03 ppm or 1 digit, whichever is greater\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cspan\u003eSalinity: ±1% of reading\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cspan\u003eTemperature: ±0.5 °C (±0.9 °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eEC\/TDS Calibration:\u003c\/strong\u003e\u003cspan\u003e single cell factor calibration, 6 standards: 84 µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm \/ one point offset: 0.00 µS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSalinity Calibration:\u003c\/strong\u003e\u003cspan\u003e one point with MA9066 salinity calibration solution\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Compensation:\u003c\/strong\u003e\u003cspan\u003e Automatic or manual from -20 to 120 °C (-4.0 to 248.0 °F) or NO TC without temperature compensation\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity temperature coefficient:\u003c\/strong\u003e\u003cspan\u003e 0.00 to 6.00 % \/ °C (EC and TDS only) | Default value: 1.90 % \/ °C\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTDS factor:\u003c\/strong\u003e\u003cspan\u003e 0.40 to 0.80 \/ Default value: 0.50\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eEC Probe:\u003c\/strong\u003e\u003cspan\u003e MA814DB\/1 4 ring\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature probe:\u003c\/strong\u003e\u003cspan\u003e Built-in temperature sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eLogging:\u003c\/strong\u003e\u003cspan\u003e Maximum 1,000 log records (stored in up to 100 lots) \/ on demand, 200 logs on stability, 200 logs, interval logging 1000 logs\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003ePC Connectivity:\u003c\/strong\u003e\u003cspan\u003e 1 micro USB port\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e 12 VDC adapter (included)\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type:\u003c\/strong\u003e\u003cspan\u003e Internal\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eBattery life:\u003c\/strong\u003e\u003cspan\u003e Approx. 8 hours of use\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment:\u003c\/strong\u003e\u003cspan\u003e 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e 230 x 160 x 95 mm (9.0 x 6.3 x 3.7 inches)\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e 0.9 kg \/ 2.00 lbs.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003e3 years meter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cspan\u003e** Absolute conductivity (or TDS) is the conductivity value without temperature compensation\u003c\/span\u003e\u003c\/p\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":58619505541445,"sku":"Spectronic MW170","price":799.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/MW170pic.jpg?v=1784488993","url":"https:\/\/auckland-scientific.co.uk\/products\/milwaukee-mw170-max-ec-tds-nacl-temp-logging-bench-meter","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}