{"product_id":"prior-scientific-h275lmt-extended-travel-motorised-focus-tower-for-nikon-evident-olympus","title":"Prior Scientific H275LMT Extended-Travel Motorised Focus Tower for Nikon \u0026 Evident\/Olympus","description":"\u003cdiv style=\"font-family: Arial, Helvetica, sans-serif; color: #25342d; line-height: 1.65; max-width: 1100px; margin: 0 auto;\"\u003e\n\n  \u003c!-- HEADER --\u003e\n  \u003cdiv style=\"background: linear-gradient(135deg, #174f3b 0%, #287457 100%); color: #ffffff; padding: 34px 30px; border-radius: 10px; margin-bottom: 28px;\"\u003e\n    \u003cp style=\"font-size: 14px; font-weight: bold; letter-spacing: 1.2px; text-transform: uppercase; margin: 0 0 8px 0;\"\u003e\n      Prior Scientific Large-Format Microscope Automation\n    \u003c\/p\u003e\n\n    \u003ch2 style=\"color: #ffffff; font-size: 30px; line-height: 1.25; margin: 0 0 16px 0;\"\u003e\n      H275LMT Extended-Travel Motorised Focus Tower\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size: 18px; margin: 0;\"\u003e\n      High-capacity motorised vertical positioning with 145 mm travel for compatible Nikon and Evident\/Olympus stereo microscopes and macroscopes.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- QUOTATION NOTICE --\u003e\n  \u003cdiv style=\"background-color: #edf6f1; border-left: 5px solid #287457; padding: 20px 22px; margin-bottom: 28px; border-radius: 4px;\"\u003e\n    \u003ch3 style=\"color: #174f3b; margin: 0 0 8px 0; font-size: 20px;\"\u003e\n      Price on quotation\n    \u003c\/h3\u003e\n\n    \u003cp style=\"margin: 0;\"\u003e\n      The H275LMT must be configured for the microscope, required adapter, motor controller, stage, sample dimensions and imaging application. Auckland Scientific will review the complete system and provide a tailored quotation.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- OVERVIEW --\u003e\n  \u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 30px 0 14px 0;\"\u003e\n    Product overview\n  \u003c\/h2\u003e\n\n  \u003cp\u003e\n    The Prior Scientific H275LMT is a large-format motorised focus tower providing 145 mm of controlled vertical travel. Instead of moving only an objective or conventional microscope stage, it supports and translates a compatible microscope optical system above the sample.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Its 25 kg load capacity allows large and complex optical assemblies to be positioned accurately, while the extended vertical travel accommodates tall, irregular or variable-height specimens that may be unsuitable for a conventional microscope stand.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    For Nikon systems, the tower is compatible with the SMZ18 and SMZ25 using the appropriate Prior adapter. For Evident\/Olympus systems, it supports the MVX10, SZX10 and SZX16 with the corresponding adapter.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    When combined with an appropriate Prior motorised XY stage, the H275LMT can form part of a complete motorised XYZ imaging system for samples measuring up to approximately 300 × 300 mm, subject to the selected stage and installation.\n  \u003c\/p\u003e\n\n  \u003c!-- KEY FEATURES --\u003e\n  \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 18px; margin: 28px 0;\"\u003e\n\n    \u003cdiv style=\"flex: 1 1 220px; background-color: #f6f9f7; border: 1px solid #d8e5de; padding: 20px; border-radius: 8px;\"\u003e\n      \u003ch3 style=\"color: #174f3b; font-size: 18px; margin: 0 0 8px 0;\"\u003e\n        145 mm vertical travel\n      \u003c\/h3\u003e\n      \u003cp style=\"margin: 0;\"\u003e\n        Extended motorised Z movement for tall, irregular and variable-height samples.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex: 1 1 220px; background-color: #f6f9f7; border: 1px solid #d8e5de; padding: 20px; border-radius: 8px;\"\u003e\n      \u003ch3 style=\"color: #174f3b; font-size: 18px; margin: 0 0 8px 0;\"\u003e\n        25 kg load capacity\n      \u003c\/h3\u003e\n      \u003cp style=\"margin: 0;\"\u003e\n        Supports large microscope bodies and complex optical assemblies above the specimen.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex: 1 1 220px; background-color: #f6f9f7; border: 1px solid #d8e5de; padding: 20px; border-radius: 8px;\"\u003e\n      \u003ch3 style=\"color: #174f3b; font-size: 18px; margin: 0 0 8px 0;\"\u003e\n        High-resolution movement\n      \u003c\/h3\u003e\n      \u003cp style=\"margin: 0;\"\u003e\n        Published resolution of 40 nm for precise motorised vertical positioning.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex: 1 1 220px; background-color: #f6f9f7; border: 1px solid #d8e5de; padding: 20px; border-radius: 8px;\"\u003e\n      \u003ch3 style=\"color: #174f3b; font-size: 18px; margin: 0 0 8px 0;\"\u003e\n        Encoded option\n      \u003c\/h3\u003e\n      \u003cp style=\"margin: 0;\"\u003e\n        H275LMTE includes a 0.1 µm linear encoder for enhanced long-range repeatability and closed-loop positioning.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- COMPATIBILITY --\u003e\n  \u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003e\n    Nikon and Evident\/Olympus compatibility\n  \u003c\/h2\u003e\n\n  \u003cp\u003e\n    This Auckland Scientific listing is specifically for the following Nikon and Evident\/Olympus microscope configurations:\n  \u003c\/p\u003e\n\n  \u003cdiv style=\"overflow-x: auto; margin: 20px 0 28px 0;\"\u003e\n    \u003ctable style=\"width: 100%; min-width: 780px; border-collapse: collapse; border: 1px solid #ccdcd3;\"\u003e\n      \u003cthead\u003e\n        \u003ctr style=\"background-color: #174f3b; color: #ffffff;\"\u003e\n          \u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eManufacturer\u003c\/th\u003e\n          \u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eCompatible microscopes\u003c\/th\u003e\n          \u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eRequired adapter\u003c\/th\u003e\n          \u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eFocus tower\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eNikon\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eSMZ18 and SMZ25\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eH275LSMZ\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eH275LMT or H275LMTE\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background-color: #f5f8f6;\"\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eEvident\/Olympus\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eMVX10, SZX10 and SZX16\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eH275LMVX\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eH275LMT or H275LMTE\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"background-color: #fff8e8; border: 1px solid #ead7a5; padding: 20px 22px; border-radius: 8px; margin: 24px 0;\"\u003e\n    \u003ch3 style=\"color: #6a5318; margin: 0 0 8px 0; font-size: 19px;\"\u003e\n      Microscope adapter required\n    \u003c\/h3\u003e\n\n    \u003cp style=\"margin: 0;\"\u003e\n      The Nikon H275LSMZ and Evident\/Olympus H275LMVX microscope adapters are separate components and are not automatically included with the focus tower. The appropriate adapter will be identified in the Auckland Scientific quotation.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TOWER OPTIONS --\u003e\n  \u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003e\n    Motorised focus tower options\n  \u003c\/h2\u003e\n\n  \u003cp\u003e\n    The required focus tower is selected during quotation. These options are shown for comparison and are not Shopify variants.\n  \u003c\/p\u003e\n\n  \u003cdiv style=\"overflow-x: auto; margin: 20px 0 28px 0;\"\u003e\n    \u003ctable style=\"width: 100%; min-width: 750px; border-collapse: collapse; border: 1px solid #ccdcd3;\"\u003e\n      \u003cthead\u003e\n        \u003ctr style=\"background-color: #174f3b; color: #ffffff;\"\u003e\n          \u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eModel\u003c\/th\u003e\n          \u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eMotorised movement\u003c\/th\u003e\n          \u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eEncoder\u003c\/th\u003e\n          \u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eRecommended use\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eH275LMT\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e200-step motor with 2 mm pitch ball screw\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eNo linear encoder\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eGeneral motorised extended-travel focus applications\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background-color: #f5f8f6;\"\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eH275LMTE\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e200-step motor with 2 mm pitch ball screw\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e0.1 µm linear encoder\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eEnhanced long-range repeatability and closed-loop positioning\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- SPECIFICATIONS --\u003e\n  \u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003e\n    Technical specifications\n  \u003c\/h2\u003e\n\n  \u003cdiv style=\"overflow-x: auto; margin: 20px 0 28px 0;\"\u003e\n    \u003ctable style=\"width: 100%; min-width: 700px; border-collapse: collapse; border: 1px solid #ccdcd3;\"\u003e\n      \u003cthead\u003e\n        \u003ctr style=\"background-color: #174f3b; color: #ffffff;\"\u003e\n          \u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eSpecification\u003c\/th\u003e\n          \u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eH275LMT\u003c\/th\u003e\n          \u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eH275LMTE\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eVertical travel\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e145 mm\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e145 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background-color: #f5f8f6;\"\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e40 nm\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e40 nm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eLinear encoder\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eNo\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e0.1 µm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background-color: #f5f8f6;\"\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eLoad capacity\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e25 kg\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e25 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eTower mass\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e13.5 kg\u003c\/td\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e13.5 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background-color: #f5f8f6;\"\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd colspan=\"2\" style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eCompatible 6 mm or 1\/4-20 optical breadboard\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eMaximum system width\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd colspan=\"2\" style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eApproximately 195.2 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr style=\"background-color: #f5f8f6;\"\u003e\n          \u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003eOverall tower height\u003c\/strong\u003e\u003c\/td\u003e\n          \u003ctd colspan=\"2\" style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eApproximately 489.7 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003cp style=\"font-size: 14px; color: #5c6962;\"\u003e\n    Published resolution describes the commanded movement of the tower. Overall imaging performance also depends on the microscope, controller, focus strategy, optical configuration, mechanical installation and sample.\n  \u003c\/p\u003e\n\n  \u003c!-- SAMPLE ACCESS --\u003e\n  \u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003e\n    Designed for large and irregular samples\n  \u003c\/h2\u003e\n\n  \u003cp\u003e\n    The interchangeable optical-system interface and adjustable installation geometry allow the H275LMT to be incorporated into large-format imaging systems with variable throat distance.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    This can provide access to samples that cannot be accommodated on a conventional stereo microscope stand, including large manufactured components, wafers, masks, display panels and whole biological specimens.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    The tower can also be configured for super-long-working-distance objectives and custom optical systems, subject to a complete mechanical and optical assessment.\n  \u003c\/p\u003e\n\n  \u003c!-- XYZ CONFIGURATION --\u003e\n  \u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003e\n    Creating a complete motorised XYZ system\n  \u003c\/h2\u003e\n\n  \u003cp\u003e\n    The H275LMT provides motorised vertical Z movement. A complete motorised XYZ installation may also include:\n  \u003c\/p\u003e\n\n  \u003cul style=\"padding-left: 24px;\"\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eA compatible Nikon or Evident\/Olympus microscope\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eThe appropriate H275LSMZ or H275LMVX microscope adapter\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eA Prior motorised XY stage selected for the sample size and application\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eHH531 stage-mounting pillars where required\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eA compatible Prior OptiScan III or ProScan III controller\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eCS200XY and CS200Z joysticks where manual positioning is required\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eAppropriate sample holders and mounting hardware\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eComputer connection and compatible imaging software\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cdiv style=\"background-color: #f2f5f3; border: 1px solid #d4ded8; padding: 18px 20px; border-radius: 7px; margin: 22px 0;\"\u003e\n    \u003cp style=\"margin: 0;\"\u003e\n      \u003cstrong\u003ePlease note:\u003c\/strong\u003e the microscope, XY stage, controller, joysticks, microscope adapter, stage mount, sample holders and cables are not included unless specifically identified in the Auckland Scientific quotation.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- SOFTWARE --\u003e\n  \u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003e\n    Software and automation\n  \u003c\/h2\u003e\n\n  \u003cp\u003e\n    The H275LMT is operated through a compatible Prior controller rather than by connecting software directly to the tower motor.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Prior states that the focus tower is compatible with imaging software that supports the relevant ProScan III controller and connected hardware. The exact controller and software combination must be confirmed for the proposed system.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Custom control may also be possible using Prior’s controller command interface and software-development resources. Where Python or other custom integration is required, Auckland Scientific will review the operating system, controller and required functions before quotation.\n  \u003c\/p\u003e\n\n  \u003c!-- APPLICATIONS --\u003e\n  \u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003e\n    Typical applications\n  \u003c\/h2\u003e\n\n  \u003cul style=\"padding-left: 24px;\"\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eSemiconductor wafer inspection\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eLarge industrial component inspection\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eMask inspection\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eLCD and display inspection\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eElectronics and printed-circuit inspection\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eLab-on-chip applications\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eHigh-throughput biological imaging\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eWhole-animal and live-animal imaging\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 7px;\"\u003eLarge or irregular specimen documentation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003c!-- DATASHEET --\u003e\n  \u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003e\n    Product literature\n  \u003c\/h2\u003e\n\n  \u003cp\u003e\n    Download the Prior Scientific H275LMT datasheet for technical dimensions, specifications and example Nikon and Evident\/Olympus configurations.\n  \u003c\/p\u003e\n\n  \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 14px; margin: 20px 0 30px 0;\"\u003e\n\n    \u003ca href=\"https:\/\/www.prior.com\/Content\/Downloads\/H275LMT_EN_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\" style=\"display: inline-block; background-color: #287457; color: #ffffff; text-decoration: none; font-weight: bold; padding: 13px 20px; border-radius: 5px;\"\u003e\n      Download H275LMT Datasheet\n    \u003c\/a\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- AUCKLAND SCIENTIFIC --\u003e\n  \u003cdiv style=\"background-color: #edf6f1; padding: 28px; border-radius: 9px; margin: 34px 0;\"\u003e\n    \u003ch2 style=\"color: #174f3b; font-size: 25px; margin: 0 0 14px 0;\"\u003e\n      Supported by Auckland Scientific\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Auckland Scientific brings more than 21 years of experience in microscopy sales, imaging applications and scientific instrumentation. Large-format systems require careful assessment of the microscope, sample, working distance, travel requirements and installation environment.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Our service can include:\n    \u003c\/p\u003e\n\n    \u003cul style=\"padding-left: 24px; margin-bottom: 0;\"\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eApplication and sample-size assessment\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eNikon or Evident\/Olympus compatibility checks\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eMicroscope adapter and tower selection\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eEncoded or non-encoded configuration guidance\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eXY stage, controller and joystick configuration\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eInstallation planning and mechanical integration\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eInstallation and commissioning\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eOperator training and workflow guidance\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eOngoing technical and service support\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- QUOTATION --\u003e\n  \u003cdiv style=\"border: 2px solid #287457; padding: 26px; border-radius: 9px; margin: 30px 0;\"\u003e\n    \u003ch2 style=\"color: #174f3b; font-size: 24px; margin: 0 0 12px 0;\"\u003e\n      Request a quotation\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      To help us specify the correct H275LMT system, please provide:\n    \u003c\/p\u003e\n\n    \u003cul style=\"padding-left: 24px;\"\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eYour Nikon or Evident\/Olympus microscope model\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eThe microscope’s current stand and optical configuration\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eMaximum sample dimensions, height and weight\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eRequired XY and Z travel\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eObjectives, magnifications and working distances\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eWhether encoded vertical positioning is required\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eThe imaging or automation software\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eAvailable bench or optical-table space\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 7px;\"\u003eInstallation, training or custom-integration requirements\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cp style=\"margin-bottom: 0;\"\u003e\n      Auckland Scientific will review the application and provide a quotation covering the tower, microscope adapter, controller, XY stage, joysticks, mounting hardware, sample holders and support services required.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- DISCLAIMER --\u003e\n  \u003cp style=\"font-size: 13px; color: #68756e; border-top: 1px solid #d7dfda; padding-top: 18px; margin-top: 34px;\"\u003e\n    Product specifications and compatibility information may change. Final mechanical, optical and software compatibility and the complete bill of materials will be confirmed at quotation stage.\n  \u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":58872045371717,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/NikonExtendedtravel.jpg?v=1786653840","url":"https:\/\/auckland-scientific.co.uk\/products\/prior-scientific-h275lmt-extended-travel-motorised-focus-tower-for-nikon-evident-olympus","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}