{"product_id":"prior-scientific-motorised-focus-mechanisms-for-leica-microscopes","title":"Prior Scientific Motorised Focus Mechanisms for Leica Microscopes","description":"\u003cdiv style=\"font-family: Arial, Helvetica, sans-serif; color: #25342d; line-height: 1.65; max-width: 1100px; margin: 0 auto;\"\u003e\n\u003c!-- INTRODUCTION --\u003e\n\u003cdiv style=\"background: linear-gradient(135deg, #174f3b 0%, #287457 100%); color: #ffffff; padding: 34px 30px; border-radius: 10px; margin-bottom: 28px;\"\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; letter-spacing: 1.2px; text-transform: uppercase; margin: 0 0 8px 0;\"\u003ePrior Scientific Automation\u003c\/p\u003e\n\u003ch2 style=\"color: #ffffff; font-size: 30px; line-height: 1.25; margin: 0 0 16px 0;\"\u003eMotorised Focus Mechanisms for Leica Microscopes\u003c\/h2\u003e\n\u003cp style=\"font-size: 18px; margin: 0;\"\u003ePrecision motorised Z-axis control for compatible manual Leica microscopes, supporting automated focusing, Z-stacking, extended-focus imaging and repeatable microscopy workflows.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- QUOTATION NOTICE --\u003e\n\u003cdiv style=\"background-color: #edf6f1; border-left: 5px solid #287457; padding: 20px 22px; margin-bottom: 28px; border-radius: 4px;\"\u003e\n\u003ch3 style=\"color: #174f3b; margin: 0 0 8px 0; font-size: 20px;\"\u003eConfigured and supplied by quotation\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eThe correct focus mechanism depends on the exact Leica microscope model, existing focus controls, preferred coupling method and controller configuration. Auckland Scientific will confirm compatibility and prepare a system-specific quotation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- PRODUCT OVERVIEW --\u003e\n\u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 30px 0 14px 0;\"\u003eProduct overview\u003c\/h2\u003e\n\u003cp\u003ePrior Scientific motorised focus mechanisms provide precise electronic control of the microscope’s fine-focus movement. On compatible manual Leica microscopes, the standard PS3H122R mechanism clamps to the focus assembly and controls the fine-focus adjustment while retaining access to manual coarse focusing.\u003c\/p\u003e\n\u003cp\u003eInstallation of the standard bolt-on mechanism does not normally require the microscope body to be inverted or dismantled. Certain Leica microscopes instead use a dedicated focus mechanism or may support a direct-coupled arrangement.\u003c\/p\u003e\n\u003cp\u003eWhen combined with a compatible Prior controller, motorised focus control can support automated Z-stacking, autofocus routines, extended-depth-of-focus imaging, slide scanning and other repeatable microscopy applications.\u003c\/p\u003e\n\u003c!-- KEY FEATURES --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 18px; margin: 28px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; background-color: #f6f9f7; border: 1px solid #d8e5de; padding: 20px; border-radius: 8px;\"\u003e\n\u003ch3 style=\"color: #174f3b; font-size: 18px; margin: 0 0 8px 0;\"\u003ePrecision Z control\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eA minimum specified step size of 0.002 µm helps retain the fine-focus resolution of the microscope mechanism.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 220px; background-color: #f6f9f7; border: 1px solid #d8e5de; padding: 20px; border-radius: 8px;\"\u003e\n\u003ch3 style=\"color: #174f3b; font-size: 18px; margin: 0 0 8px 0;\"\u003eSimple integration\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eBolt-on configurations can be installed without dismantling the microscope body.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 220px; background-color: #f6f9f7; border: 1px solid #d8e5de; padding: 20px; border-radius: 8px;\"\u003e\n\u003ch3 style=\"color: #174f3b; font-size: 18px; margin: 0 0 8px 0;\"\u003eAnti-twist cable\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eThe no-twist cable arrangement helps prevent the focus-drive cable from rotating with the mechanism.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 220px; background-color: #f6f9f7; border: 1px solid #d8e5de; padding: 20px; border-radius: 8px;\"\u003e\n\u003ch3 style=\"color: #174f3b; font-size: 18px; margin: 0 0 8px 0;\"\u003eAutomation ready\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eCompatible configurations can be controlled through Prior ProScan III or OptiScan III controllers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- COMPATIBILITY --\u003e\n\u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003eLeica microscope compatibility\u003c\/h2\u003e\n\u003cp\u003eThe following combinations are based on Prior Scientific’s published compatibility information. Compatibility must be reconfirmed against the full microscope model and configuration before ordering.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0 28px 0;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 720px; border-collapse: collapse; border: 1px solid #ccdcd3;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #174f3b; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eLeica microscope\u003c\/th\u003e\n\u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eFocus mechanism\u003c\/th\u003e\n\u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eRequired adapter\u003c\/th\u003e\n\u003cth style=\"padding: 13px; text-align: left; border: 1px solid #ccdcd3;\"\u003eConfiguration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eDMR and DMIR\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003ePS3H122R\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eH968\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eBolt-on focus drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f8f6;\"\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eDM2000 and DM2500\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003ePS3H122R\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eH2754\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eBolt-on focus drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eDM4000, DM5000 and DM6000\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003ePS3H122R\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eH2581\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eBolt-on focus drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f8f6;\"\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eDM4000, DM5000 and DM6000\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003ePS3H122DM4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eDedicated configuration\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eDirect-coupled focus mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eDMLS\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e\u003cstrong\u003ePS3H122LS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eDedicated configuration\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eModel-specific focus mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- DIRECT COUPLING --\u003e\n\u003cdiv style=\"background-color: #fff8e8; border: 1px solid #ead7a5; padding: 20px 22px; border-radius: 8px; margin: 24px 0;\"\u003e\n\u003ch3 style=\"color: #6a5318; margin: 0 0 8px 0; font-size: 19px;\"\u003eDirect coupling and alternative configurations\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 10px 0;\"\u003eThe H122KLC fine-focus coupling is listed by Prior for selected Leica DMLM, DM2000 and DM2500 configurations. Its suitability depends on the microscope’s existing focus arrangement and must be confirmed before ordering.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eDirect coupling can provide a more rigid connection to the fine-focus mechanism and may improve repeatability, but it is not available or required for every Leica microscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003ePS3H122R specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 28px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccdcd3;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f5f8f6;\"\u003e\n\u003cth style=\"width: 40%; padding: 12px; text-align: left; border: 1px solid #ccdcd3; color: #174f3b;\"\u003eFocus movement\u003c\/th\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eFine-focus control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 12px; text-align: left; border: 1px solid #ccdcd3; color: #174f3b;\"\u003eMinimum specified step size\u003c\/th\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e0.002 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f8f6;\"\u003e\n\u003cth style=\"padding: 12px; text-align: left; border: 1px solid #ccdcd3; color: #174f3b;\"\u003eTravel range\u003c\/th\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003eDetermined by the microscope focus mechanism; specified by Prior as unlimited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 12px; text-align: left; border: 1px solid #ccdcd3; color: #174f3b;\"\u003eMaximum load\u003c\/th\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f5f8f6;\"\u003e\n\u003cth style=\"padding: 12px; text-align: left; border: 1px solid #ccdcd3; color: #174f3b;\"\u003eCable length\u003c\/th\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 12px; text-align: left; border: 1px solid #ccdcd3; color: #174f3b;\"\u003eController compatibility\u003c\/th\u003e\n\u003ctd style=\"padding: 12px; border: 1px solid #ccdcd3;\"\u003ePrior ProScan III and OptiScan III controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 14px; color: #5c6962;\"\u003eSpecifications shown principally relate to the standard PS3H122R mechanism. Dedicated Leica focus mechanisms may have different specifications. Final performance also depends on the microscope’s mechanical focus system and complete automation configuration.\u003c\/p\u003e\n\u003c!-- SOFTWARE --\u003e\n\u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003eSoftware and automation integration\u003c\/h2\u003e\n\u003cp\u003eThe focus mechanism is operated through a compatible Prior controller. Prior lists the PS3H122R motorised focus drive as compatible with third-party microscopy platforms including:\u003c\/p\u003e\n\u003cul style=\"padding-left: 24px; margin-top: 12px;\"\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eµManager\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eInscoper\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eVisiView\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSoftware support depends on the selected controller, communications interface, software version and appropriate device configuration. Compatibility with a particular Leica software package should not be assumed unless it has been confirmed for the proposed system.\u003c\/p\u003e\n\u003ch3 style=\"color: #174f3b; font-size: 20px; margin: 24px 0 8px 0;\"\u003ePython and custom software\u003c\/h3\u003e\n\u003cp\u003eCustom control from Python is possible through the Prior controller rather than by connecting software directly to the focus motor. Prior’s SDK 2.0 is based on a C\/C++ DLL and includes Python examples, allowing developers to incorporate supported Prior hardware into custom automation workflows.\u003c\/p\u003e\n\u003cp\u003ePython integration should therefore be described as SDK-based development support, not as a standalone ready-to-use Python application. The operating system, controller model, interface and required functionality should be reviewed before specifying a custom solution.\u003c\/p\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003eTypical applications\u003c\/h2\u003e\n\u003cul style=\"padding-left: 24px;\"\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eAutomated Z-stacking\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eExtended-depth-of-focus imaging\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eAutomated slide scanning\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eRepeatable focus positioning\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eTime-lapse microscopy\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eAutofocus and image-analysis workflows\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eCustom OEM and laboratory automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- WHAT IS REQUIRED --\u003e\n\u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003eWhat may be required\u003c\/h2\u003e\n\u003cp\u003eA complete motorised-focus system may include:\u003c\/p\u003e\n\u003cul style=\"padding-left: 24px;\"\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eThe appropriate Prior motorised focus mechanism\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eA Leica microscope-specific mounting adapter\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eAn optional direct fine-focus coupling, where supported\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eA Prior ProScan III or OptiScan III controller\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eA joystick or other manual control device, if required\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eComputer connection and suitable imaging or automation software\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eAdditional motorised XY stages, filter wheels or automation components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background-color: #f2f5f3; border: 1px solid #d4ded8; padding: 18px 20px; border-radius: 7px; margin: 22px 0;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e controllers, microscope adapters, direct couplings, joysticks and other accessories are not necessarily included with the focus mechanism and will be specified separately in the quotation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- DOWNLOADS --\u003e\n\u003ch2 style=\"color: #174f3b; font-size: 26px; margin: 34px 0 14px 0;\"\u003eProduct literature and downloads\u003c\/h2\u003e\n\u003cp\u003eDownload the available technical information below. These documents support product selection but do not replace a model-specific compatibility check.\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 14px; margin: 20px 0 30px 0;\"\u003e\n\u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"display: inline-block; background-color: rgb(40, 116, 87); text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial; padding: 13px 20px; border-radius: 5px;\"\u003e\u003cb\u003e\u003ca href=\"https:\/\/www.prior.com\/Content\/Downloads\/PS3H122R_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003e Download PS3H122R Datasheet\u003c\/a\u003e \u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e \u003c!-- Replace the URL below with the Shopify Files URL after uploading the PDF --\u003e \u003cspan style=\"color: #174f3b;\"\u003e\u003cspan style=\"display: inline-block; background-color: rgb(255, 255, 255); text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial; padding: 12px 20px; border: 2px solid rgb(40, 116, 87); border-radius: 5px;\"\u003e\u003cb\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/Prior-Microscope-Components-Software-Compatibility.pdf?v=1786645660\" rel=\"noopener\" target=\"_blank\"\u003eDownload Software Compatibility Guide \u003c\/a\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c!-- AUCKLAND SCIENTIFIC --\u003e\n\u003cdiv style=\"background-color: #edf6f1; padding: 28px; border-radius: 9px; margin: 34px 0;\"\u003e\n\u003ch2 style=\"color: #174f3b; font-size: 25px; margin: 0 0 14px 0;\"\u003eSupported by Auckland Scientific\u003c\/h2\u003e\n\u003cp\u003eAuckland Scientific brings more than 21 years of experience supporting microscopy, imaging and scientific-instrumentation applications. We work with customers to understand the microscope, samples, imaging method and automation objectives before recommending a system.\u003c\/p\u003e\n\u003cp\u003eOur service can include:\u003c\/p\u003e\n\u003cul style=\"padding-left: 24px; margin-bottom: 0;\"\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003ePre-purchase consultation and application review\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eMicroscope and component compatibility checks\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eSelection of the correct focus drive, adapter and controller\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eInstallation and commissioning\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eUser and operator training\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eSoftware and workflow guidance\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eOngoing technical and service support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- QUOTATION INFORMATION --\u003e\n\u003cdiv style=\"border: 2px solid #287457; padding: 26px; border-radius: 9px; margin: 30px 0;\"\u003e\n\u003ch2 style=\"color: #174f3b; font-size: 24px; margin: 0 0 12px 0;\"\u003eRequest a quotation\u003c\/h2\u003e\n\u003cp\u003eTo help us specify the correct configuration, please provide:\u003c\/p\u003e\n\u003cul style=\"padding-left: 24px;\"\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eYour Leica microscope model\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eA photograph of the microscope and focus controls\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eThe microscope serial number or approximate age, if available\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eYour existing motorised stage or Prior controller, if applicable\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eThe imaging software you intend to use\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 7px;\"\u003eWhether you require installation, training or custom integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003eAuckland Scientific will review the information and provide a quotation for the appropriate focus mechanism, mounting components, controller and support services.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- DISCLAIMER --\u003e\n\u003cp style=\"font-size: 13px; color: #68756e; border-top: 1px solid #d7dfda; padding-top: 18px; margin-top: 34px;\"\u003eProduct names and microscope model references are used to identify compatibility. Prior Scientific specifications and compatibility information may change. Final suitability and the complete bill of materials will be confirmed at quotation stage.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Auckland Scientific","offers":[{"title":"Default Title","offer_id":58871787848005,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1066\/1930\/6309\/files\/motorisedfocusdrive_ceb0e9ba-051a-4a65-aadd-1b0d63c25366.jpg?v=1786650479","url":"https:\/\/auckland-scientific.co.uk\/products\/prior-scientific-motorised-focus-mechanisms-for-leica-microscopes","provider":"Auckland Scientific Ltd","version":"1.0","type":"link"}