C-Mount & Camera Sensor Compatibility Checker
Select a C-mount adapter and camera sensor format to see the likely effect on field of view and image coverage.
1
Select your combination
Choose the C-mount adapter and the camera sensor you want to use together.
2
See the effect
The result and biological thin-section illustration update automatically.
GOOD MATCH
0.55× C-mount + 1/1.8" sensor
Recommended pairing
This combination makes good use of the available image circle and should provide a broad camera field.
Recommended sensor1/1.8"
Selected sensor1/1.8"
The vivid area in the rectangle represents the part of the specimen captured by the camera.
Interactive field-of-view illustration
Blue circle = C-mount image circle
Green rectangle = camera sensor
Illustrative biological thin section. The area inside the sensor rectangle is shown more vividly to demonstrate the portion captured by the camera.
GreenGood / recommended match
AmberUsable or borderline — check the intended system
RedSensor likely exceeds the useful image circle
Quick reference
The highlighted row shows the normal starting sensor size for the selected C-mount.
| C-mount | Recommended sensor | Practical guidance |
|---|---|---|
| 0.35× | 1/3" | Small sensors / wide field |
| 0.45× | 1/2.5" | Small-to-medium sensors |
| 0.50× | 1/2" | Common general-purpose pairing |
| 0.55× | 1/1.8" | Broad field with a slightly larger sensor |
| 0.63× | 2/3" | Typical 2/3" sensor pairing |
| 0.65× | 2/3" | Useful alternative for 2/3" sensors |
| 0.70× | 2/3" | 2/3" with slightly greater image magnification |
| 0.75× | 2/3" | Higher image magnification with 2/3" format |
| 0.80× | 1/1.1" | Starting point for larger sensor formats |
| 1.00× | 1" | Large sensor / no reduction |
| 1.20× | 1" | Large sensor with greater image magnification |
Need help with an exact microscope or camera?
Send us the microscope model, camera model or sensor specification and we can help check the most suitable C-mount combination.
Please note: this is a practical selection aid rather than a guarantee of optical compatibility.
Actual coverage depends on the microscope photo port, the specific adapter optics and its usable image circle.
Borderline combinations should be checked on the intended system.
© 2026 Auckland Scientific Ltd.
Interactive tool, software, graphics and original content. All rights reserved.
Unauthorised copying, reproduction, republication, modification or redistribution is prohibited.
Interactive tool, software, graphics and original content. All rights reserved.
Unauthorised copying, reproduction, republication, modification or redistribution is prohibited.