Clifton NE8S Digital Laboratory Incubators – 15L 32L 56L 112L & 240L
Clifton NE8S Digital Laboratory Incubators
Precision digital laboratory incubators providing stable, controlled-temperature conditions for incubation and general laboratory applications.
NE8S Digital Laboratory Incubators
The Clifton NE8S Digital Laboratory Incubators are designed to provide controlled and repeatable temperature conditions for laboratory incubation and general temperature-sensitive applications.
The range is available in five chamber capacities from 15 litres to 240 litres, allowing the appropriate model to be selected according to sample volume, available laboratory space and required chamber capacity.
All models provide a temperature range of ambient +5°C to 100°C and incorporate PID digital temperature control with a clear illuminated LED display.
The NE8S combines digital PID control with a PT100 temperature sensor, flexible air circulation options and automatic over-temperature protection for dependable laboratory operation.
Available Models
| Product Code | Chamber Capacity | Heater Power | Internal Dimensions | External Dimensions |
|---|---|---|---|---|
| NE8-15S | 15 Litres | 1050 W | 320 × 180 × 240 mm | 520 × 390 × 600 mm |
| NE8-32S | 32 Litres | 1100 W | 400 × 250 × 320 mm | 600 × 460 × 680 mm |
| NE8-56S | 56 Litres | 2150 W | 400 × 400 × 360 mm | 600 × 605 × 720 mm |
| NE8-112S | 112 Litres | 2150 W | 400 × 450 × 620 mm | 600 × 660 × 980 mm |
| NE8-240S | 240 Litres | 3200 W | 600 × 510 × 800 mm | 800 × 720 × 1160 mm |
PID Digital Temperature Control
The NE8S range uses PID digital temperature control to provide accurate adjustment and monitoring of the incubation temperature. The illuminated LED display can show either the actual or selected temperature.
0.1°C Resolution
Temperature is displayed digitally with 0.1°C resolution for straightforward monitoring.
PT100 Sensor
A PT100 temperature sensor provides temperature measurement and control diagnostics during power-up.
100°C Maximum
The controlled temperature range extends from ambient +5°C to 100°C.
Designed for Incubation
The NE8S is designed specifically for applications where maintaining a controlled and stable elevated temperature is more important than high-temperature oven operation.
With a maximum operating temperature of 100°C, the range is well suited to controlled incubation, sample conditioning and general laboratory procedures requiring consistent warming conditions.
Digital control, sensor feedback and selectable air circulation help provide a controlled chamber environment throughout the incubation process.
Gravity or Forced-Air Circulation
The NE8S range can be configured for either gravity convection or forced-air circulation with variable fan speed.
Gravity Convection
A natural circulation option for applications where gentle temperature distribution is preferred.
Variable-Speed Fan
Forced-air circulation can be selected where enhanced chamber air movement is required.
Automatic Over-Temperature Protection
An automatic over-temperature alarm provides an additional level of protection during operation. The alarm is automatically set at 5°C above the selected set point.
The automatic alarm helps identify unintended temperature increases during controlled incubation.
Flexible Timer Operation
The NE8S controller provides flexible operating modes to accommodate different laboratory procedures.
Immediate Operation
Start operation immediately and maintain the selected incubation temperature.
Run-Back Timer
Use the run-back timer for procedures requiring controlled operation for a defined period.
Delay Start
Configure delayed starting where the incubation process needs to begin at a later time.
Adjustable Shelving
Adjustable shelving allows the chamber to be configured around different sample sizes and loading requirements.
| Model | Shelves Supplied | Maximum Shelves |
|---|---|---|
| NE8-15S | 1 | 3 |
| NE8-32S | 2 | 5 |
| NE8-56S | 2 | 8 |
| NE8-112S | 3 | 10 |
| NE8-240S | 3 | 10 |
Technical Specifications
| Specification | NE8-15S | NE8-32S | NE8-56S | NE8-112S | NE8-240S |
|---|---|---|---|---|---|
| Capacity | 15 L | 32 L | 56 L | 112 L | 240 L |
| Temperature Range | Ambient +5°C to 100°C | ||||
| Temperature Control | PID Digital LED Display 0.1°C Resolution | ||||
| Temperature Sensor | PT100 with control diagnostics at power-up | ||||
| Temperature Alarm | Automatically set 5°C above set point | ||||
| Temperature Fluctuation | ±0.4°C at 37°C | ||||
| Heater Power | 1050 W | 1100 W | 2150 W | 2150 W | 3200 W |
| Voltage | 230 V 50/60 Hz | ||||
Choose Your NE8S Incubator
NE8-15S · 15 L
Compact 15 litre incubator for applications where chamber capacity and laboratory space are limited.
NE8-32S · 32 L
Versatile 32 litre chamber offering additional capacity while retaining a compact laboratory footprint.
NE8-56S · 56 L
56 litre capacity for larger sample volumes and increased laboratory workloads.
NE8-112S · 112 L
Large 112 litre chamber for higher-volume incubation and temperature-controlled laboratory applications.
NE8-240S · 240 L
Maximum-capacity 240 litre model for applications requiring substantial chamber volume.
Laboratory Applications
The Clifton NE8S series is suitable for a wide range of laboratory incubation and controlled-temperature applications.
- Laboratory incubation
- Controlled sample incubation
- Temperature-sensitive sample storage during procedures
- General laboratory warming applications
- Microbiological and biological laboratory applications where appropriate
- Routine temperature-controlled laboratory procedures
Clifton Laboratory Quality
The Clifton range is manufactured by Nickel-Electro Ltd, a British manufacturer specialising in laboratory temperature-control equipment. The NE8S series combines robust construction with straightforward digital operation and controlled temperature performance.
Available from 15 litres through to 240 litres with controlled operation from ambient +5°C to 100°C.
Specifications are based on Clifton NE8S manufacturer documentation. Product specifications may be subject to manufacturer updates.